Saad Yousaf

Mr. Saad Yousaf

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
KGKeya Ghonasgi
Keya Ghonasgi
SYSaad Yousaf
Saad Yousaf
Paria EsmatlooParia Esmatloo
Paria Esmatloo
ADAshish Deshpande
Ashish Deshpande
Measurement of interaction forces distributed across the attachment interface in wearable devices is critical for understanding ergonomic physical human–robot interaction (pHRI). The main challenges in sensorization of pHRI interfaces are (i) capturing the fine nature of force transmission from compliant human tissue onto rigid surfaces in the wearable device and (ii) utilizing a low-cost and easily implementable design that can be adapted for a variety of human interfaces. This paper addresses both challenges and presents a modular sensing panel that uses force-sensing resistors (FSRs) combined with robust electrical and mechanical integration principles that result in a reliable solution for distributed load measurement. The design is demonstrated through an upper-arm cuff, which uses 24 sensing panels, in conjunction with the Harmony exoskeleton. Validation of the design with controlled loading of the sensorized cuff proves the viability of FSRs in an interface sensing solution. Preliminary experiments with a human subject highlight the value of distributed interface force measurement in recognizing the factors that influence ergonomic pHRI and elucidating their effects. The modular design and low cost of the sensing panel lend themselves to extension of this approach for studying ergonomics in a variety of wearable applications with the goal of achieving safe, comfortable, and effective human–robot interaction.

23 October 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
SYSaad Yousaf
Saad Yousaf
GMGaurav Mukherjee
Gaurav Mukherjee
RKRaymond King
Raymond King
ADAshish Deshpande
Ashish Deshpande
Even the best wearable robots face challenges with power losses in the system, especially at the physical attachment interface. While some sources for power loss are inherent to the system, such as human soft tissue or musculoskeletal joint damping, other sources such as soft padding materials and bias strap forces can be modulated to optimize interface power transmission. Few methods currently exist for estimating power loss at physical human-robot interfaces, especially for upper-body exoskeletons. This letter presents a novel method to estimate interface power from experimental data in a wearable hand device, along with a simulation model for predicting interaction behavior by incorporating viscoelastic properties at the attachment interface. The experimental method is implemented with the Maestro hand exoskeleton, and repeatability of the interface power estimation is confirmed with pilot human testing. Simulation results are compared with experimental estimation of interface power, showing agreement of trends and validating the use of a simulation model to predict physical human-robot interaction behavior. These findings highlight the advantages of multi-body simulations as a tool to perform modular, inexpensive, and predictive investigations in physical human-robot interaction, without affecting the real-world mechatronic system or hindering the subject's safety. The proposed tools for experimental estimation of interface power and simulation modeling can optimize the design and control of robots for seamless integration with the human body.

12 July 2021
Verified
Conference Paper
Closed access
SYSaad Yousaf
Saad Yousaf
KGKeya Ghonasgi
Keya Ghonasgi
Paria EsmatlooParia Esmatloo
Paria Esmatloo
ADAshish Deshpande
Ashish Deshpande
The viscoelastic properties of human soft tissue influence the nature of interaction at attachment points in wearable devices. Characterizing these properties is especially critical for understanding physical human-robot interaction (pHRI) for exoskeleton design, prosthetics, and similar fields. This paper presents the design and control of a novel actuated indenter for the measurement of human soft tissue properties. The accuracy of position (0.025 mm) and force (111 mN) measurements allows for repeatable and controlled tissue deformation and monitoring at 36 different angular locations (10° increments). Controlled indentation displacement with force feedback is used in three types of applications on a human subject’s forearm. The soft tissue stiffness profile, viscoelastic relaxation behavior, and frequency domain response are measured. The ability to perform multiple characterizations with one indenter device broadens the scope of a human-centered approach to design, modeling, and perception as they relate to pHRI interfaces.

2 March 2026 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
HZHaiyun Zhang
Haiyun Zhang
Stefano Dalla GasperinaStefano Dalla Gasperina
Stefano Dalla Gasperina
SYSaad Yousaf
Saad Yousaf
JRJob D. Ramirez
Job D. Ramirez
TTToshimitsu Tsuboi
Toshimitsu Tsuboi
ADAshish Deshpande
Ashish Deshpande
Hand exoskeletons are critical tools for dexterous teleoperation and immersive manipulation interfaces, but achieving accurate hand tracking remains a challenge due to user-specific anatomical variability and donning inconsistencies. These issues lead to kinematic misalignments that degrade tracking performance and limit applicability in precision tasks. We propose a subject-specific calibration framework for exoskeleton-based hand tracking that estimates virtual link parameters through residual-weighted optimization. A data-driven approach is introduced to empirically tune cost function weights using motion capture ground truth, enabling accurate and consistent calibration across users. Implemented on the Maestro hand exoskeleton with seven healthy participants, the method achieved substantial reductions in joint and fingertip tracking errors across diverse hand geometries. Qualitative visualizations using a Unity-based virtual hand further demonstrate improved motion fidelity. While demonstrated on the Maestro exoskeleton, the framework can be extended to other hand exoskeleton systems that provide comparable kinematic constraints and sensing capabilities.