Yosuke Ito

Prof. Dr. Yosuke Ito

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2005 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
OSO Sakai
O Sakai
TST Sakaguchi
T Sakaguchi
YIYosuke Ito
Yosuke Ito
KTK Tachibana
K Tachibana

13 January 2015 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
KKKeigo Kamada
Keigo Kamada
DSDaichi Sato
Daichi Sato
YIYosuke Ito
Yosuke Ito
HNHiroaki Natsukawa
Hiroaki Natsukawa
KOKazuhisa Okano
Kazuhisa Okano
TKTetsuo Kobayashi
Tetsuo Kobayashi
In the field of biomagnetic measurements, optically pumped atomic magnetometers (OPAMs) are expected to be alternative sensors to magnetometers based on superconducting quantum interference devices (SQUIDs). In addition, miniaturized OPAMs are required for practical use. To address this issue, we developed a compact module of a high-sensitivity OPAM with a pump–probe arrangement and potassium used as the sensing atom. Because the noise spectrum density of the OPAM reached 21 fT rms /Hz 1/2 at 10 Hz, we attempted to use it to measure human magnetocardiograms (MEGs). Compared with the results obtained with SQUID-based magnetometers, we could successfully observe distinct features of event-related desynchronization in the 8–13 Hz band associated with eye opening. The results demonstrate the feasibility of using the OPAM module for neuromagnetic field measurements.

29 June 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
YIYosuke Ito
Yosuke Ito
DSDaichi Sato
Daichi Sato
KKKeigo Kamada
Keigo Kamada
TKTetsuo Kobayashi
Tetsuo Kobayashi
An optically pumped K–Rb hybrid atomic magnetometer can be a useful tool for biomagnetic measurements due to the high spatial homogeneity of its sensor property inside a cell. However, because the property varies depending on the densities of potassium and rubidium atoms, optimization of the densities is essential. In this study, by using the Bloch equations of K and Rb and considering the spatial distribution of the spin polarization, we confirmed that the calculation results of spin polarization behavior are in good agreement with the experimental data. Using our model, we calculated the spatial distribution of the spin polarization and found that the optimal density of K atoms is 3 × 1019 m−3 and the optimal density ratio is nK/nRb ~ 400 to maximize the output signal and enhance spatial homogeneity of the sensor property.

26 September 2011 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
YIYosuke Ito
Yosuke Ito
HOHiroyuki Ohnishi
Hiroyuki Ohnishi
KKKeigo Kamada
Keigo Kamada
TKTetsuo Kobayashi
Tetsuo Kobayashi
An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.

24 May 2012 in Physiological Measurement
Verified
Journal Article
Closed access
KKK Kamada
K Kamada
YIYosuke Ito
Yosuke Ito
TKT Kobayashi
T Kobayashi
Measuring biomagnetic fields, such as magnetocardiograms (MCGs), is important for investigating biological functions. To address to this need, we developed an optically pumped atomic magnetometer. In this study, human MCGs were acquired using a potassium atomic magnetometer without any modulating systems. The sensitivity of the magnetometer is comparable to that of high-T(c) superconducting quantum interference devices (SQUIDs) and is sufficient for acquiring human MCGs. The activity of a human heart estimated from the MCG maps agrees well with that measured with SQUID magnetometers. Thus, our magnetometer produces reliable results, which demonstrate the potential of our atomic magnetometer for biomagnetic measurements.

13 June 2008 in Applied Physics Express
Verified
Journal Article
Closed access
KUKeiichiro Urabe
Keiichiro Urabe
YIYosuke Ito
Yosuke Ito
KTKunihide Tachibana
Kunihide Tachibana
BGBiswa N. Ganguly
Biswa N. Ganguly