Tiejun Chang

Dr. Tiejun Chang


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Jack XiongJack Xiong
Jack Xiong
AAAmit Angal
Amit Angal
TCTiejun Chang
Tiejun Chang
KCKwofu Chiang
Kwofu Chiang
NLNing Lei
Ning Lei
AWAisheng Wu
Aisheng Wu
Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) have successfully operated since their launches in 1999 and 2002, respectively, and generated various data products to support the Earth remote sensing disciplines and users worldwide for their research activities and applications, including studies of the Earth system, and its changes over time and geographic regions. The MODIS data have also significantly contributed to the continuity of multi-decadal satellite data records and led to major advances in the Earth remote sensing field. The long-term data records from MODIS observations have been and will continue to be extended by the Visible Infrared Imaging Radiometer Suite (VIIRS) instruments, currently operated aboard the Suomi-National Polar-Orbiting Partnership (NPP) and NOAA-20 satellites. The data quality of satellite instruments strongly depends on their calibration accuracy and stability. In order to help scientists and users gain a better understanding of MODIS and VIIRS data quality, this paper provides an overview of their on-orbit calibration methodologies, approaches, and results derived from instrument on-board calibrators and lunar observations, as well as select Earth view targets. What is also discussed is the calibration consistency between MODIS and VIIRS and its potential impact on producing multi-sensor long-term data records. As illustrated, the overall performance of both MODIS and VIIRS continues to meet their design requirements.

27 May 2017 in Remote Sensing
Verified
Journal Article
Open access
PDF file
QMQiaozhen Mu
Qiaozhen Mu
AWAisheng Wu
Aisheng Wu
Jack XiongJack Xiong
Jack Xiong
DDDavid Doelling
David Doelling
AAAmit Angal
Amit Angal
RBRajendra Bhatt
Rajendra Bhatt
MODIS reflective solar bands are calibrated on-orbit using a solar diffuser and near-monthly lunar observations. To monitor the performance and effectiveness of the on-orbit calibrations, pseudo-invariant targets such as deep convective clouds (DCCs), Libya-4, and Dome-C are used to track the long-term stability of MODIS Level 1B product. However, the current MODIS operational DCC technique (DCCT) simply uses the criteria set for the 0.65-µm band. We optimize several critical DCCT parameters including the 11-µm IR-band Brightness Temperature (BT11) threshold for DCC identification, DCC core size and uniformity to help locate DCCs at convection centers, data collection time interval, and probability distribution function (PDF) bin increment for each channel. The mode reflectances corresponding to the PDF peaks are utilized as the DCC reflectances. Results show that the BT11 threshold and time interval are most critical for the Short Wave Infrared (SWIR) bands. The Bidirectional Reflectance Distribution Function model is most effective in reducing the DCC anisotropy for the visible channels. The uniformity filters and PDF bin size have minimal impacts on the visible channels and a larger impact on the SWIR bands. The newly optimized DCCT will be used for future evaluation of MODIS on-orbit calibration by MODIS Characterization Support Team.

1 August 2005 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
TCTiejun Chang
Tiejun Chang
YLYe Liu
Ye Liu
ACAlan E. Craig
Alan E. Craig
A method for the design of waveguide-coupled microring resonators is described based on an improved coupled mode theory (CMT) approach. Characteristic parameters including coupling efficiency and Q factor are theoretically analyzed. The effects of variations in the refractive index, waveguide width, bus-to-ring gap spacing, and ring radius are investigated. The accuracy of this model is evaluated by comparing its predicted calculation results to those of the numerical beam propagation method (BPM) and finite difference time domain (FDTD) simulations obtained using commercial software. The predictions of the model agree well with the simulation results.

15 August 2016 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
TCTiejun Chang
Tiejun Chang
Jack XiongJack Xiong
Jack Xiong
QMQiaozhen Mu
Qiaozhen Mu
This work takes advantage of the stable distribution of deep convective cloud (DCC) reflectance measurements to assess the calibration stability and detector difference in Visible Infrared Imaging Radiometer Suite (VIIRS) reflective bands. VIIRS Sensor Data Records (SDRs) from February 2012 to June 2015 are utilized to analyze the long-term trending, detector difference, and half angle mirror (HAM) side difference. VIIRS has two thermal emissive bands with coverage crossing 11 μm for DCC pixel identification. The comparison of the results of these two processing bands is one of the indicators of analysis reliability. The long-term stability analysis shows downward trends (up to approximately 0.4% per year) for the visible and near-infrared bands and upward trends (up to 0.5% per year) for the shortand midwave infrared bands. The detector difference for each band is calculated as the difference relative to the average reflectance over all detectors. Except for the slightly greater than 1% difference in the two bands at 1610 nm, the detector difference is less than 1% for other solar reflective bands. The detector differences show increasing trends for some short-wave bands with center wavelengths from 400 to 600 nm and remain unchanged for the bands with longer center wavelengths. The HAM side difference is insignificant and stable. Those short-wave bands from 400 to 600 nm also have relatively larger HAM side difference, up to 0.25%. Comparing the striped images from SDR and the smooth images after the correction validates the analyses of detector difference and HAM side difference. These analyses are very helpful for VIIRS calibration improvement and thus enhance product quality.

1 July 2023 in Journal of Applied Remote Sensing
Verified
Journal Article
Closed access
PDF file
Jack XiongJack Xiong
Jack Xiong
AAAmit Angal
Amit Angal
TCTiejun Chang
Tiejun Chang
EAEmily J. Aldoretta
Emily J. Aldoretta
XGXu Geng
Xu Geng
AWAisheng Wu
Aisheng Wu
Since its launch in May, 2002, Aqua MODIS has successfully operated for more than 20 years and has continuously generated a wide range of data products that have enabled and supported the remote sensing community and users worldwide for their studies of the Earth’s system by monitoring changes in its key environmental parameters. Although Aqua MODIS, designed with a lifetime requirement of 6 years, is currently operated in its extended mission phase, it continues to make high quality global observations of the Earth’s surface via its 36 spectral bands that cover wavelengths from visible to long-wave infrared. To date, all instrument on-board calibrators (OBC) remain capable of performing their design functions, providing various calibration data sets to help monitor on-orbit changes in sensor responses and performance characteristics. In addition to the OBC, regularly scheduled lunar observations and select Earth-view targets are used extensively to support sensor on-orbit calibration, especially for the calibration of the visible channels (or bands). We provide an overview of Aqua MODIS on-orbit calibration activities and methodologies for both reflective solar bands and thermal emissive bands, illustrate its on-orbit performance over the past 20 years using examples derived from OBC measurements, lunar observations, and Earth-view response trends, and describe various calibration improvements made over its entire mission. We focus on key issues identified since launch, such as solar diffuser degradation, electronic crosstalk, and on-orbit changes in sensor response versus scan-angle, along with approaches and strategies developed to mitigate their impact on sensor calibration quality. Also discussed in this paper are some of the key calibration enhancements incorporated recently in the Collection 6.1 and the upcoming Collection 7 Level-1B algorithms.

1 July 2020 in Journal of Applied Remote Sensing
Verified
Journal Article
Closed access
PDF file
Jack XiongJack Xiong
Jack Xiong
EAEmily Aldoretta
Emily Aldoretta
AAAmit Angal
Amit Angal
TCTiejun Chang
Tiejun Chang
XGXu Geng
Xu Geng
AWAisheng Wu
Aisheng Wu
<!-- *** Custom HTML *** --> Since its launch in December 1999, Terra Moderate Resolution Imaging Spectroradiometer (MODIS) has successfully operated for more than 20 years, with its observations generating a broad range of science data products that have greatly enabled the remote sensing community and users worldwide in their studies of many key geophysical parameters of the Earth’s systems. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, which are calibrated by a set of onboard calibrators (OBCs). Also contributing to the sensor’s mission-long on-orbit calibration and characterization are near-monthly scheduled lunar observations and multiple time series of the sensor’s responses over select ground targets at a variety of scan angles. To a large extent, the quality of MODIS data products relies strongly on the dedicated efforts to operate and calibrate the instrument, to derive and update calibration parameters, and to develop and implement new calibration strategies and algorithms in response to on-orbit changes of the sensor’s characteristics and its OBC functions. We provide an overview of the Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve the instrument and OBC functions and their operation strategies. It also illustrates the sensor’s on-orbit performance with results derived from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms as well as calibration lookup table updates. To date, the Terra MODIS instrument and its OBCs continue to operate and function normally. Except for those identified prelaunch, most spectral bands and detectors continue to meet their specified calibration requirements. Also discussed in our paper are lessons learned from Terra MODIS operation and calibration, as well as future efforts to further extend and maintain the quality of its long-term data records.