Gitte Slingers

Mrs. Gitte Slingers


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2023 in Journal of Cystic Fibrosis
Verified
Journal Article
Closed access
JLJohann-Christoph Licht
Johann-Christoph Licht
ESElias Seidl
Elias Seidl
GSGitte Slingers
Gitte Slingers
VWValerie Waters
Valerie Waters
RVRianne de Vries
Rianne de Vries
HGHartmut Grasemann
Hartmut Grasemann

30 October 2020 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
GSGitte Slingers
Gitte Slingers
MEMartin Vanden Eede
Martin Vanden Eede
JLJill Lindekens
Jill Lindekens
MSMaarten Spruyt
Maarten Spruyt
EGEddy Goelen
Eddy Goelen
GKGudrun Koppen
Gudrun Koppen

30 June 2020 in Journal of Breath Research
Verified
Journal Article
Closed access
PDF file
GSGitte Slingers
Gitte Slingers
RGRob Goossens
Rob Goossens
HJHeleen Janssens
Heleen Janssens
MSMaarten Spruyt
Maarten Spruyt
EGEddy Goelen
Eddy Goelen
GKGudrun Koppen
Gudrun Koppen
Breath-based non-invasive diagnostics have the potential to provide valuable information about a person’s health status. However, they are not yet widely used in clinical practice due to multiple factors causing variability and the lack of standardized procedures. This study focuses on the comparison of oral and nasal breathing, and on the variability of volatile metabolites over the short and long term. Selected ion flow tube mass spectrometry (SIFT-MS) was used for online analysis of selected volatile metabolites in oral and nasal breath of 10 healthy individuals five times in one day (short-term) and six times spread over three weeks (long-term), resulting in nearly 100 breath samplings. Intra-class correlation coefficients (ICCs) were used to assess short- and long-term biological variability. Additionally, the composition of ambient air was analyzed at different samplings. The selected volatiles common in exhaled breath were propanol, 2,3-butanedione, acetaldehyde, acetone, ammonia, dimethyl sulfide, isoprene, pentane, and propanal. Additionally, environmental compounds benzene and styrene were analyzed as well. Volatile metabolite concentrations in ambient air were not correlated with those in exhaled breath and were significantly lower than in breath samples. All volatiles showed significant correlation between oral and nasal breath. Five were significantly higher in oral breath compared to nasal breath, while for acetone, propanal, dimethyl sulfide, and ammonia, concentrations were similar in both matrices. Variability depended on the volatile metabolite. Most physiologically relevant volatiles (acetone, isoprene, propanol, acetaldehyde) showed good to very good biological reproducibility (ICC > 0.61) mainly in oral breath and over a short-term period of one day. Both breathing routes showed relatively similar patterns; however, bigger differences were expected. Therefore, since sampling from the mouth is practically more easy, the latter might be preferred.

8 May 2020
Verified
Preprint
Open access
JMJoline Millen
Joline Millen
IWIbbo Willems
Ibbo Willems
GSGitte Slingers
Gitte Slingers
MRMarc Raes
Marc Raes
GKGudrun Koppen
Gudrun Koppen
SLSabine Langie
Sabine Langie
Background: Allergic sensitization is commonly assessed in patients by performing the skin prick test (SPT) or determining specific IgE levels in blood samples with the ImmunoCAP assay, which measures each allergen and sample separately. This paper explores the possibility to investigate respiratory allergies with a high throughput method, the Meso Scale Discovery (MSD) multiplex immunoassay, measuring IgE levels in low volumes of blood. Methods: The MSD multiplex immunoassay, developed and optimized with standards and allergens from Radim, was validated against the SPT and the ImmunoCAP assay. For 18 adults (15 respiratory allergy patients and 3 controls), blood collection and the SPT were performed within the same hour. Results: Pearson correlations and Bland-Altman analysis showed high comparability of the MSD multiplex immunoassay and the ImmunoCAP assay, except for house dust mite. The sensitivity of the MSD multiplexed assay was ≥75% for most allergens compared to the SPT and ImmunoCAP assay. Additionally, the specificity of the MSD multiplex immunoassay was ≥80% - the majority showing 100% specificity. Only the rye allergen had a low specificity when compared to the SPT, probably due to cross-reactivity. The reproducibility of the MSD multiplex immunoassay, assessed as intra- and inter-assay reproducibility and biological variability between different sampling moments, showed significantly high correlations ( r =0.943-1) for all tested subjects (apart from subject 13; r =0.65-0.99). Conclusion: The MSD multiplex immunoassay is a reliable method to detect specific IgE levels against respiratory allergens in a multiplexed and high throughput way, using blood samples as small as from a finger prick.

10 June 2020
Verified
Preprint
Open access
JMJoline Millen
Joline Millen
IWIbbo Willems
Ibbo Willems
GSGitte Slingers
Gitte Slingers
MRMarc Raes
Marc Raes
GKGudrun Koppen
Gudrun Koppen
SLSabine Langie
Sabine Langie
Allergic sensitization is commonly assessed in patients by performing the skin prick test (SPT) or determining specific IgE levels in blood samples with the ImmunoCAP assay, which measures each allergen and sample separately. This paper explores the possibility to investigate respiratory allergies with a high throughput method, the Meso Scale Discovery (MSD) multiplex immunoassay, measuring IgE levels in low volumes of blood. The MSD multiplex immunoassay, developed and optimized with standards and allergens from Radim, was validated against the SPT and the ImmunoCAP assay. For 18 adults (15 respiratory allergy patients and 3 controls), blood collection and the SPT were performed within the same hour. Pearson correlations and Bland-Altman analysis showed high comparability of the MSD multiplex immunoassay and the ImmunoCAP assay, except for house dust mite. The sensitivity of the MSD multiplexed assay was ≥75% for most allergens compared to the SPT and ImmunoCAP assay. Additionally, the specificity of the MSD multiplex immunoassay was ≥80% - the majority showing 100% specificity. Only the rye allergen had a low specificity when compared to the SPT, probably due to cross-reactivity. The reproducibility of the MSD multiplex immunoassay, assessed as intra- and inter-assay reproducibility and biological variability between different sampling moments, showed significantly high correlations ( r =0.943-1) for all tested subjects (apart from subject 13; r =0.65-0.99). The MSD multiplex immunoassay is a reliable method to detect specific IgE levels against respiratory allergens in a multiplexed and high throughput way, using blood samples as small as from a finger prick.

7 August 2023
Verified
Preprint
Open access
PDF file
GSGitte Slingers
Gitte Slingers
GJGriet Jacobs
Griet Jacobs
MSMaarten Spruyt
Maarten Spruyt
EGEddy Goelen
Eddy Goelen
JSJordy Stans
Jordy Stans
MRMarc Raes
Marc Raes
Background Early differentiation of rattling infants, frequently misdiagnosed as wheezing, is important to prevent under- and overtreatment. Exhaled breath biomarkers reflect metabolic processes and can potentially aid differential diagnosis. This study investigated the potential of exhaled biomarkers in differentiating rattling infants. Methods Exhaled breath collected from infants (2-18months) with an adjusted breath sampler was analysed using gas chromatography mass spectrometry (GC-MS) and selected ion flow tube mass spectrometry (SIFT-MS). Linear discriminant analysis was used to classify recovered, mild, moderate and severe rattling infants in a one-vs-all approach. The potential of parent reported outcome about symptoms and burden to improve the discriminant models was also investigated. Results Classifying the diagnostic groups (recovered, mild, moderate, severe rattling) based on exhaled breath showed potential with accuracies between 69.12-75.0% for GC-MS and 59.21-69.74% for SIFT-MS. Highest accuracy and specificity was achieved for severe rattling vs all other diagnostic groups. Adding parent reported symptoms in past the three days to the discriminant model increased accuracies (69.12-86.76% GC-MS; 65.79-88.16% SIFT-MS), particularly for moderate and severe rattling infants. The differentiating VOCs were of the type alkane, acids, amine, imine, triazine and ketone. Conclusion Exhaled breath analysis has potential to differentiate infants with different rattling severities and recovered infants. Additionally, combining parent reported symptoms in the past three days with exhaled breath biomarkers improved the performance of the diagnostic models.