The aim of this study was to evaluate the ability of a prototype intraoperative mini γ-camera, the CarolIReS, with a 50 × 50 mm field of view, to precisely localize sentinel lymph nodes (SLNs) and to determine their depth in a series of patients with infiltrative breast cancer requiring SLN excision. Methods: With the use of phantoms, the broadness of the signal of an acquired projection was shown to linearly depend on its distance from the collimator. A preclinical ex vivo study of 25 excised SLNs demonstrated that SLN size did not influence depth estimation. The minimum activity threshold for successful use of the proposed method was determined. After a preoperative radioisotope injection and lymphoscintigraphy, the SLN was localized in a series of 11 patients using both the mini γ-camera and a γ-probe. During surgery, a ruler was used to measure the depth of all SLNs before their excision. Results: Using the measured linear dependence of image broadness, we found that the expected SLN anatomic depth was compatible with its measured depth during surgery. Conclusion: This study showed that the mini γ-camera efficiently estimated the location of SLNs in 3 dimensions.
Background: This systematic review aimed at comparing performances of ultrasonography (US), magnetic resonance imaging (MRI), and fluorodeoxyglucose positron emission tomography (PET) for axillary staging, with a focus on micro- or micrometastases. Methods: A search for relevant studies published between January 2002 and March 2018 was conducted in MEDLINE database. Study quality was assessed using the QUality Assessment of Diagnostic Accuracy Studies checklist. Sensitivity and specificity were meta-analyzed using a bivariate random effects approach; Results: Across 62 studies (n = 10,374 patients), sensitivity and specificity to detect metastatic ALN were, respectively, 51% (95% CI: 43–59%) and 100% (95% CI: 99–100%) for US, 83% (95% CI: 72–91%) and 85% (95% CI: 72–92%) for MRI, and 49% (95% CI: 39–59%) and 94% (95% CI: 91–96%) for PET. Interestingly, US detects a significant proportion of macrometastases (false negative rate was 0.28 (0.22, 0.34) for more than 2 metastatic ALN and 0.96 (0.86, 0.99) for micrometastases). In contrast, PET tends to detect a significant proportion of micrometastases (true positive rate = 0.41 (0.29, 0.54)). Data are not available for MRI. Conclusions: In comparison with MRI and PET Fluorodeoxyglucose (FDG), US is an effective technique for axillary triage, especially to detect high metastatic burden without upstaging majority of micrometastases.
Membrane contact sites between organelles are organized by protein bridges. Among the components of these contacts, the VAP family comprises ER–anchored proteins, such as MOSPD2, that function as major ER–organelle tethers. MOSPD2 distinguishes itself from the other members of the VAP family by the presence of a CRAL-TRIO domain. In this study, we show that MOSPD2 forms ER–lipid droplet (LD) contacts, thanks to its CRAL-TRIO domain. MOSPD2 ensures the attachment of the ER to LDs through a direct protein–membrane interaction. The attachment mechanism involves an amphipathic helix that has an affinity for lipid packing defects present at the surface of LDs. Remarkably, the absence of MOSPD2 markedly disturbs the assembly of lipid droplets. These data show that MOSPD2, in addition to being a general ER receptor for inter-organelle contacts, possesses an additional tethering activity and is specifically implicated in the biology of LDs via its CRAL-TRIO domain.
Recent developments in micro-CT have revolutionized the ability to examine in vivo living experimental animal models such as mouse with a spatial resolution less than 50 microm. The main requirements of in vivo imaging for biological researchers are a good spatial resolution, a low dose induced to the animal during the full examination and a reduced acquisition and reconstruction time for screening purposes. We introduce inline acquisition and reconstruction architecture to obtain in real time the 3D attenuation map of the animal fulfilling the three previous requirements. The micro-CT system is based on commercially available x-ray detector and micro-focus x-ray source. The reconstruction architecture is based on a cluster of PCs where a dedicated communication scheme combining serial and parallel treatments is implemented. In order to obtain high performance transmission rate between the detector and the reconstruction architecture, a dedicated data acquisition system is also developed. With the proposed solution, the time required to filter and backproject a projection of 2048 x 2048 pixels inside a volume of 140 mega voxels using the Feldkamp algorithm is similar to 500 ms, the time needed to acquire the same projection.
1 June 2018 in Annales de Chirurgie Plastique Esthétique
Granulomatous mastitis is a rare and often considered as idiopathic disease. However, clinical examination and thorough diagnostic investigations have to be carried out in order to identify cases that are secondary to infections or systemic diseases since these forms may be cured with appropriate etiologic treatment. To the best of our knowledge, this report is the first to describe the association of granulomatous mastitis with Sjögren’s syndrome. We discuss the clinical, pathological and therapeutic implications of this association.