We compared the independent predictive factors for moderate and severe injuries, along with characteristics and outcomes of motor vehicle collisions, between pregnant and non-pregnant women. Using 2001–2015 records from the National Automotive Sampling System/Crashworthiness Data System, we selected 736 pregnant women and 21,874 non-pregnant women having any anatomical injuries. Pregnant women showed less severe collisions, fewer fatalities, and less severe injuries in most body regions than non-pregnant women. In pregnant women, the rate of sustaining abbreviated injury scale (AIS) scores 2+ injuries was higher for the abdomen only. For non-pregnant women, rear seat position, airbag deployment, multiple collisions, rollover, force from the left, and higher collision velocity had a positive influence on the likelihood of AIS 2+ injuries, and seatbelt use and force from the rear had a negative influence. There is a need for further development of passive safety technologies for restraint and active safety features to slow down vehicles and mitigate collisions. The influencing factors identified may be improved by safety education. Therefore, simple and effective interventions by health professionals are required that are tailored to pregnant women.
To examine the factors that influence substantial injuries for pregnant women and negative fetal outcomes in motor vehicle collisions (MVCs), a retrospective analysis using the National Automotive Sampling System/Crashworthiness Data System was performed in Shiga University of Medical Science. We analyzed data from 736 pregnant women who, between 2001 and 2015, had injuries that were an abbreviated injury scale (AIS) score of one or more. The mean age was 25.9 ± 6.4 years and the mean gestational age was 26.2 ± 8.2 weeks. Additionally, 568 pregnant women had mild injuries and 168 had moderate to severe injuries. Logistic regression analysis revealed that seatbelt use (odds ratio (OR), 0.30), airbag deployment (OR, 2.00), and changes in velocity (21–40 km/h: OR, 3.03; 41–60 km/h: OR, 13.47; ≥61 km/h: OR, 44.56) were identified as independent predictors of having a moderate to severe injury. The positive and negative outcome groups included 231 and 12 pregnant women, respectively. Injury severity in pregnant women was identified as an independent predictor of a negative outcome (OR, 2.79). Avoiding moderate to severe maternal injuries is a high priority for saving the fetus, and education on appropriate seatbelt use and limiting vehicle speed for pregnant women is required.
Few studies have compared the sensitivities of autopsy and post mortem computed tomography (PMCT) in detecting rib fractures caused by cardiopulmonary resuscitation (CPR). We aimed to compare the characteristics between both modalities for accurately detecting CPR-related rib fractures. This single-centre observational study included adult patients with autopsy records and PMCT scans at our institution from January 2013 to March 2019. CPR-related rib fractures were evaluated using autopsy and PMCT findings. In 62 patients enrolled, 339 rib fractures were detected on autopsy and/or PMCT (222 fractures on both PMCT and autopsy, 69 on PMCT alone, and 50 on autopsy alone). The agreement of detection for both modalities was substantial (kappa coefficient, 0.78). In the logistic regression model, incomplete fractures detected by PMCT and age <75 years were significantly associated with findings that were negative on autopsy but positive on PMCT, while rib number (ribs 1–3 and 7–12) and fracture location (posterolateral and paravertebral) were significantly associated with negative PMCT findings but positive autopsy findings. Autopsy and PMCT showed complementary roles, and are thus necessary in accurately detecting CPR-related rib fractures. Combining both modalities may contribute to improved CPR quality and better understanding of discrepancy in characteristics between the two modalities.
To determine the cause of negative fetal outcomes and the causative mechanism in a frontal collision, we analyzed the kinematics and mechanisms of injuries using an unbelted pregnant dummy, the Maternal Anthropometric Measurement Apparatus dummy, version 2B. Sled tests were performed to recreate frontal impact situations with impact speeds of 13, 26, and 40 km/h. Overall kinematics of the dummy were examined through high-speed video imaging. Quantitative dummy responses—such as time courses of the abdominal pressure, chest deflection, neck injury criteria (Nij), and displacement of the pelvis during impact—were also measured. The maximum abdominal pressure of 103.3 kPa was obtained at an impact speed of 13 km/h. The maximum chest deflection of 38.5 mm and Nij of 0.36 were obtained at an impact speed of 26 km/h. The highest maximum chest deflection of >40.9 mm, Nij of 0.61, and forward pelvis displacement of 478 mm were obtained at an impact speed of 40 km/h. Although the kinematics and mechanism of injuries of the dummy were different for different collision speeds, we found that unbelted pregnant drivers suffer severe or fatal injuries to the fetus even in low-speed collisions.
Because decedents undergoing forensic autopsies would have behaved normally before death, prostate volume according to age group can be confirmed with forensic autopsy materials. The objectives of this study were to first confirm the current prostate volume by age and then determine diseases that can influence prostate volume using forensic autopsy materials. Prostate specimens were collected from forensic autopsies performed at Shiga University of Medical Science, Japan, between January 2015 and December 2019. Overall, 207 decedents were included in the study. Prostate volume was measured by the Archimedes’ principle. Concomitant diseases were determined by the past medical histories and autopsy results. The mean crude prostate volume was 29.1 ± 10.3 mL (range, 2.8–88.0 mL). The crude prostate volume increased with age. The mean corrected prostate volume (divided by body surface area) was significantly higher in patients with atherosclerosis than in those without. However, multiple regression analysis revealed that only age influenced the corrected prostate volume. Age was the only significant influencing factor for prostate volume. We propose applying age estimation using prostate volume for forensic medicine purposes. Because prostate volume was not influenced by concomitant disease, it would be valuable to estimate the decedent’s age using the prostate volume.