Juan Ramírez

Juan Ramírez


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2011 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
DLDamien Lacroix
Damien Lacroix
Juan RamírezJuan Ramírez
Juan Ramírez

19 March 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Sofia C. HenaoSofia C. Henao
Sofia C. Henao
COCamila Orozco
Camila Orozco
Juan RamírezJuan Ramírez
Juan Ramírez
A Finite Element Analysis (FEA) was performed to evaluate the interaction between residual limb and socket when considering the dynamic loads of the gait cycle. Fourteen transfemoral amputees participated in this study, where their residual limbs (i.e., soft tissues and bone), and their sockets were reconstructed. The socket and the femur were defined as elastic materials, while the bulk soft tissues were defined as a hyperelastic material. Each model included the donning, standing, and gait cycle phase, with load and boundary conditions applied accordingly. The influence of adding the dynamic loads related to the gait cycle were compared against the modelling of the static load equivalent to the standing position resulting in changes of 23% ± 19% in the maximum values and in an increase in the size of the regions where they were located. Additionally, the possible correspondence between comfort and the location of peak loadbearing at the residual-limb/socket interface was explored. Consequently, the comfort perceived by the patient could be estimated based on the locations of the maximum stresses (i.e., if they coincide with the pressure tolerant or sensitive regions of the residual limb).

1 December 2012 in Prosthetics and Orthotics International
Verified
Journal Article
Open access
Juan RamírezJuan Ramírez
Juan Ramírez
JVJaime Andrés Vélez
Jaime Andrés Vélez
Many finite element investigations have been made in the field of lower limb prosthetics; however, friction between bone and soft tissues as a boundary condition has not been considered. To establish whether the change in the contact boundary condition between bone and soft tissues in a transfemoral amputee affects the stress-strain state on the residual limb. Finite element analysis comparison. Finite element models of four transfemoral amputees were developed. In these models the socket, soft tissues and femur were included and two simulations were made for each model, in one of them the interaction between bone and soft tissues was defined as tied (there is no relative displacement between surfaces) and in the other it was defined as a friction boundary condition. The von Mises stress and strain peaks are higher when the friction definition is used than for tied contact definition. The distribution pattern of stresses and strains also change when the contact definition varies from tied to friction. It was concluded that the friction between bone and soft tissues have a significant impact on the results of finite element models of lower limb prosthetic systems, and therefore in its predictive capabilities. Understanding the bone-soft tissue interaction can lead to more realistic and accurate finite element models used to predict the stress-strain state in the residual limb of prosthetic users and therefore predict the occurrence of deep tissue injuries.

22 December 2023 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
VPViviana Marcela Posada Perez
Viviana Marcela Posada Perez
Juan RamírezJuan Ramírez
Juan Ramírez
ACAna Civantos
Ana Civantos
Patricia Fernández-MoralesPatricia Fernández-Morales
Patricia Fernández-Morales
JAJean Paul Allain
Jean Paul Allain

1 December 2011 in Prosthetics and Orthotics International
Verified
Journal Article
Open access
Juan RamírezJuan Ramírez
Juan Ramírez
JIJésica Andrea Isaza
Jésica Andrea Isaza
IMIsabela Mariaka
Isabela Mariaka
JVJaime Andrés Vélez
Jaime Andrés Vélez
Background: There is a relation between Hounsfield units obtained from computed tomography (CT) scans and bone density. The density of the bones can be used to establish its mechanical properties and therefore to assess the bone mechanical condition using CT images. Objectives: To identify the effect of the transfemoral amputation and the use of external lower limb prosthesis in the bone properties, by comparing Young’s modulus. Study Design: Young’s modulus comparison. Methods: Comparison of bone density between the healthy femur and the amputated bone of 20 unilateral transfemoral amputees was done by generating three histograms of the Hounsfield units at different parts of the femur. The histograms were created based on images obtained by CT and the Hounsfield units were translated to Young’s modulus to establish the comparison. Results: The results show a significant difference (p-value <0.05) between the mean value of Young’s modulus of healthy and amputated bone. Conclusions: There is clearly a direct association between the use of external prosthesis and the bone demineralization due the stress shielding phenomenon. The Young’s modulus comparison using information from CT images can be a suitable tool to analyze the bone demineralization due to the use of exoprosthesis.