Scott Wade

Prof. Scott Wade

Faculty of Science, Engineering and Technology, Swinburne University of Technology, Melbourne, Australia
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2003 in Journal of Applied Physics
Verified
Journal Article
Closed access
Scott WadeScott Wade
Scott Wade
SCS. F. Collins
S. F. Collins
GBG. W. Baxter
G. W. Baxter
The fluorescence intensity ratio technique for optical fiber-based point temperature sensing is reviewed, including the materials suitable for this technique. The temperature dependence of the fluorescence intensity ratio has been studied using thermally coupled energy levels in seven different rare earth ions doped into a variety of glasses and crystals. Sensor prototypes developed using Pr3+:ZBLANP, Nd3+-doped silica fiber and Yb3+-doped silica fiber as the sensing material have been used to measure temperatures covering the range of approximately −50 to 600 °C with a resolution of the order of 1 °C.

14 October 1998 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
SCS. F. Collins
S. F. Collins
GBG. W. Baxter
G. W. Baxter
Scott WadeScott Wade
Scott Wade
TST. Sun
T. Sun
KGK. T. V. Grattan
K. T. V. Grattan
APA. W. Palmer
A. W. Palmer
The performance of the two most promising fluorescence-based temperature sensing techniques, namely the fluorescence intensity ratio (FIR) and fluorescence lifetime (FL) schemes, have been compared. Theoretical calibration graphs for the two methods illustrate the useful monotonic change of the response with temperature variation. Comparison of the responses and the sensitivities of the two schemes show that at very low temperatures the FIR method exhibits a significant variation with temperature, while the response of the FL method becomes constant with its sensitivity approaching zero. With increasing temperature, the FIR and the FL methods (with short relaxation times and shorter intrinsic lifetimes of the upper energy levels) share a similar sensitivity over a wide temperature range. The presence of a long relaxation time or a longer intrinsic lifetime of the upper level in the use of the FL method gives a less satisfactory response. Experimental data obtained for a range of dopant ions in various host materials are found to be consistent with the theoretical expectation, with each material having a specific energy gap difference. The sensitivities of each material are compared graphically which would allow the most appropriate sensor for an intended application to be selected.

2 September 2013 in Journal of Raman Spectroscopy
Verified
Journal Article
Open access
PDF file
PCP. J. Cadusch
P. J. Cadusch
MHMya Myintzu Hlaing
Mya Myintzu Hlaing
Scott WadeScott Wade
Scott Wade
SMSally McArthur
Sally McArthur
PSPaul Stoddart
Paul Stoddart
Raman spectroscopy has attracted interest as a non‐invasive optical technique to study the composition and structure of a wide range of materials at the microscopic level. The intrinsic fluorescence background can be orders of magnitude stronger than the Raman scattering, and so, background removal is one of the foremost challenges for quantitative analysis of Raman spectra in many samples. A range of methods anchored in instrumental and computational programming approaches have been proposed for removing fluorescence background signals. An enhanced adaptive weighting scheme for automated fluorescence removal is reported, applicable to both polynomial fitting and penalized least squares approaches. Analysis of the background fitting results for ensembles of simulated spectra suggests that the method is robust and reliable and can significantly improve the background fit over the range of signal, shot noise and background parameters tested, while reducing the subjective nature of the process. The method was also illustrated by application to experimental data generated from aqueous solutions of bulk protein fibrinogen mixed with dextran. Copyright © 2013 John Wiley & Sons, Ltd.

1 April 2015 in Corrosion Science
Verified
Journal Article
Closed access
MJM.A. Javed
M.A. Javed
PSPaul Stoddart
Paul Stoddart
Scott WadeScott Wade
Scott Wade

15 May 2007 in Journal of Applied Physics
Verified
Journal Article
Closed access
CWC. Wallbrink
C. Wallbrink
Scott WadeScott Wade
Scott Wade
Rhys JonesRhys Jones
Rhys Jones
An investigation into the effect of size on the quantitative estimation of defect depth in a steel specimen has been undertaken using lock-in thermography. Phase contrast measurements over circular defects of varying diameter and depth are presented for a range of excitation frequencies. It was found that the diameter of a defect had an appreciable effect on the observed phase angle which consequently has significant implications with regard to estimating defect depth. Phase contrast measurements for a range of defects in a 10mm steel specimen indicate that an excitation frequency of 0.02Hz is the optimal frequency for defect detection. Results obtained with an excitation frequency of 0.02Hz are used to discuss the limitations of determining the size and depth of defects. A finite element analysis was found to have good correlation with experimental data and thus demonstrates potential in providing improved estimates of defect depth.

1 June 2015 in Hearing Research
Verified
Journal Article
Closed access
ATAlexander C. Thompson
Alexander C. Thompson
JFJames B. Fallon
James B. Fallon
AWAndrew K. Wise
Andrew K. Wise
Scott WadeScott Wade
Scott Wade
RSRobert K. Shepherd
Robert K. Shepherd
PSPaul Stoddart
Paul Stoddart