Alberto Audenino

Prof. Alberto Audenino

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2013 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
FPF. Pennella
F. Pennella
GCG. Cerino
G. Cerino
DMDiana Massai
Diana Massai
DGD. Gallo
D. Gallo
GLG. Falvo D’urso Labate
G. Falvo D’urso Labate
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci

8 November 2019 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
ARAlice Ravizza
Alice Ravizza
Carmelo De MariaCarmelo De Maria
Carmelo De Maria
LPLicia Di Pietro
Licia Di Pietro
FSFederico Sternini
Federico Sternini
AAAlberto Audenino
Alberto Audenino
CBCristina Bignardi
Cristina Bignardi
Medical devices are designed, tested, and placed on the market in a highly regulated environment. Wearable sensors are crucial components of various medical devices: design and validation of wearable sensors, if managed according to international standards, can foster innovation while respecting regulatory requirements. The purpose of this paper is to review the upcoming European Union (EU) Medical Device Regulations 2017/745 and 2017/746, the current and future International Electrotechnical Commission (IEC) and International Organization for Standardization (ISO) standards that set methods for design and validation of medical devices, with a focus on wearable sensors. Risk classification according to the regulation is described. The international standards IEC 62304, IEC 60601, ISO 14971, and ISO 13485 are reviewed to define regulatory restrictions during design, pre-clinical validation and clinical validation of devices that include wearable sensors as crucial components. This paper is not about any specific innovation but it is a toolbox for interpreting current and future regulatory restrictions; an integrated method for design planning, validation and clinical testing is proposed. Application of this method to design wearable sensors should be evaluated in the future in order to assess its potentially positive impact to fostering innovation and to ensure timely development.

4 May 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DMDiana Massai
Diana Massai
GIGiuseppe Isu
Giuseppe Isu
DMDenise Madeddu
Denise Madeddu
GCGiulia Cerino
Giulia Cerino
AFAngela Falco
Angela Falco
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci
A versatile bioreactor suitable for dynamic suspension cell culture under tunable shear stress conditions has been developed and preliminarily tested culturing cancer cell spheroids. By adopting simple technological solutions and avoiding rotating components, the bioreactor exploits the laminar hydrodynamics establishing within the culture chamber enabling dynamic cell suspension in an environment favourable to mass transport, under a wide range of tunable shear stress conditions. The design phase of the device has been supported by multiphysics modelling and has provided a comprehensive analysis of the operating principles of the bioreactor. Moreover, an explanatory example is herein presented with multiphysics simulations used to set the proper bioreactor operating conditions for preliminary in vitro biological tests on a human lung carcinoma cell line. The biological results demonstrate that the ultralow shear dynamic suspension provided by the device is beneficial for culturing cancer cell spheroids. In comparison to the static suspension control, dynamic cell suspension preserves morphological features, promotes intercellular connection, increases spheroid size (2.4-fold increase) and number of cycling cells (1.58-fold increase), and reduces double strand DNA damage (1.5-fold reduction). It is envisioned that the versatility of this bioreactor could allow investigation and expansion of different cell types in the future.

1 May 2018 in Journal of Biomechanics
Verified
Journal Article
Closed access
GGGianvito Grasso
Gianvito Grasso
SMStefano Muscat
Stefano Muscat
MRMartina Rebella
Martina Rebella
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci
AAAlberto Audenino
Alberto Audenino
MDMarco A. Deriu
Marco A. Deriu

1 January 2013 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
DMDiana Massai
Diana Massai
GCGiulia Cerino
Giulia Cerino
DGDiego Gallo
Diego Gallo
FPFrancesco Pennella
Francesco Pennella
MDMarco A. Deriu
Marco A. Deriu
Umberto MorbiducciUmberto Morbiducci
Umberto Morbiducci
Cardiovascular disease is the leading cause of morbidity and mortality in the Western World. The inability of fully differentiated, load‐bearing cardiovascular tissues to in vivo regenerate and the limitations of the current treatment therapies greatly motivate the efforts of cardiovascular tissue engineering to become an effective clinical strategy for injured heart and vessels. For the effective production of organized and functional cardiovascular engineered constructs in vitro, a suitable dynamic environment is essential, and can be achieved and maintained within bioreactors. Bioreactors are technological devices that, while monitoring and controlling the culture environment and stimulating the construct, attempt to mimic the physiological milieu. In this study, a review of the current state of the art of bioreactor solutions for cardiovascular tissue engineering is presented, with emphasis on bioreactors and biophysical stimuli adopted for investigating the mechanisms influencing cardiovascular tissue development, and for eventually generating suitable cardiovascular tissue replacements.

1 April 2013 in Journal of Sports Sciences
Verified
Journal Article
Closed access
Elisabetta ZanettiElisabetta Zanetti
Elisabetta Zanetti
CBCristina Bignardi
Cristina Bignardi
GFGiordano Franceschini
Giordano Franceschini
AAAlberto Audenino
Alberto Audenino
Artificial turf is being used more and more often. It is more available than natural turf for use, requires much less maintenance and new products are able to comply with sport performance and athletes’ safety. The purpose of this paper is to compare the mechanical and biomechanical responses of two different artificial turf infills (styrene butadiene rubber, from granulated vehicle tires, and thermoplastic rubber granules) and to compare them to the performance of natural fields where amateurs play (beaten earth, substantially). Three mechanical parameters have been calculated from laboratory tests: energy storage, energy losses and surface traction coefficient; results have been correlated with peak accelerations recorded on an instrumented athlete, on the field. The natural ground proved to be stiffer (−15% penetration depth for a given load), and to have a lower dynamic traction coefficient (−48%); the different kinds of infill showed significantly different stiffnesses (varying by more than 23%) and damping behaviour (varying by more than 31%). In running, peak vertical accelerations were lowest in the artificial ground with thermoplastic rubber granules, while, in slalom, both artificial grounds produced higher horizontal peak accelerations compared to the natural ground. Results are discussed in terms of their implications for athletic performance and injury risk.