F. Javier Salgado-Remacha

Dr. F. Javier Salgado-Remacha

Departamento de Física Aplicada, Facultad de Ciencias, Universidad de Zaragoza, 50009 Zaragoza, Spain
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2020 in Optics Letters
Verified
Journal Article
Closed access
PDF file
FSF. Javier Salgado-Remacha
F. Javier Salgado-Remacha
BABenjamín Alonso
Benjamín Alonso
HCHelder Crespo
Helder Crespo
CCC. Cojocaru
C. Cojocaru
JTJ. Trull
J. Trull
ILIñigo Sola Larrañaga
Iñigo Sola Larrañaga
We demonstrate a novel dispersion-scan (d-scan) scheme for single-shot temporal characterization of ultrashort laser pulses. The novelty of this method relies on the use of a highly dispersive crystal featuring antiparallel nonlinear domains with a random distribution and size. This crystal, capable of generating a transverse second-harmonic signal, acts simultaneously as the dispersive element and the nonlinear medium of the d-scan device. The resulting in-line architecture makes the technique very simple and robust, allowing the acquisition of single-shot d-scan traces in real time. The retrieved pulses are in very good agreement with independent frequency-resolved optical grating measurements. We also apply the new single-shot d-scan to a terawatt-class laser equipped with a programmable pulse shaper, obtaining an excellent agreement between the applied and the d-scan retrieved dispersions.

12 March 2020 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ASAna Sanchez-Cano
Ana Sanchez-Cano
JSJosé Eduardo Saldaña-Díaz
José Eduardo Saldaña-Díaz
LPLorena Perdices
Lorena Perdices
IPIsabel Pinilla
Isabel Pinilla
FSF. Javier Salgado-Remacha
F. Javier Salgado-Remacha
SJSebastián Jarabo
Sebastián Jarabo
An optical fiber-based supercontinuum setup and a custom-made spectrophotometer that can measure spectra from 1100 to 2300 nm, are used to describe attenuation properties from different ex vivo rat tissues. Our method is able to differentiate between scattering and absorption coefficients in biological tissues. Theoretical assumptions combined with experimental measurements demonstrate that, in this infrared range, tissue attenuation and absorption can be accurately measured, and scattering can be described as the difference between both magnitudes. Attenuation, absorption, and scattering spectral coefficients of heart, brain, spleen, retina, and kidney are given by applying these theoretical and experimental methods. Light through these tissues is affected by high scattering, resulting in multiple absorption events, and longer wavelengths should be used to obtain lower attenuation values. It can be observed that the absorption coefficient has a similar behavior in the samples under study, with two main zones of absorption due to the water absorption bands at 1450 and 1950 nm, and with different absolute absorption values depending on the constituents of each tissue. The scattering coefficient can be determined, showing slight differences between retina and brain samples, and among heart, spleen and kidney tissues.

8 October 2014 in Applied Optics
Verified
Journal Article
Open access
PDF file
FSF. Javier Salgado-Remacha
F. Javier Salgado-Remacha
The lack of intensity in the central region of Laguerre–Gaussian beams reduces their applicability as illumination sources. For this reason, it is usual to shape a Laguerre–Gaussian beam to a nearly Gaussian beam using a binary phase mask. The behavior of this rectified Laguerre–Gaussian beam is analyzed in this work in the Fresnel regime. A comparison between diverse Laguerre–Gaussian beams with rectified Laguerre–Gaussian beams shows that there appear two different regions along the propagation axis: first is a transition region (for lower distances) with a flat intensity distribution, and next is a second region (for longer distances) where the rectified Laguerre–Gaussian tends to a Gaussian shape. The results of this work are very valuable for the use of this kind of beam in micro-optical applications.

2 August 2016 in Laser Physics Letters
Verified
Journal Article
Open access
PDF file
JSJ E Saldaña-Díaz
J E Saldaña-Díaz
SJS Jarabo
S Jarabo
FSF. Javier Salgado-Remacha
F. Javier Salgado-Remacha
We report a simple method for supercontinuum generation. The set-up consists of an Er-doped mode-locked fibre laser, used as seed, and a highly nonlinear fibre with zero dispersion at 1550 nm. Thus, all the components are easily attainable. With this novel system the requirements in terms of control of dispersion are reduced. In addition, the spectral width is optimized using fibres with positive and negative dispersion. The supercontinuum emission is characterized by means of an optical spectrum analyser and a PbS photodetector, showing an octave-spanning spectral width, with a flat profile from 1100 nm up to 2100 nm. Compared to other supercontinuum sources, this new proposal results in a very competitive and attainable system, particularly in the 1500–2100 nm region.

Verified
Journal Article
Open access
PDF file
GEGuisela Fernández Espinosa
Guisela Fernández Espinosa
CRCarlos Ruiz-Tabuenca
Carlos Ruiz-Tabuenca
EOElvira Orduna-Hospital
Elvira Orduna-Hospital
Isabel PinillaIsabel Pinilla
Isabel Pinilla
FSF. Javier Salgado-Remacha
F. Javier Salgado-Remacha
Background: Manual segmentation of the Foveal Avascular Zone (FAZ) has a high level of variability. Research into retinas needs coherent segmentation sets with low variability. Methods: Retinal optical coherence tomography angiography (OCTA) images from type-1 diabetes mellitus (DM1), type-2 diabetes mellitus (DM2) and healthy patients were included. Superficial (SCP) and deep (DCP) capillary plexus FAZs were manually segmented by different observers. After comparing the results, a new criterion was established to reduce variability in the segmentations. The FAZ area and acircularity were also studied. Results: The new segmentation criterion produces smaller areas (closer to the real FAZ) with lower variability than the different criteria of the explorers in both plexuses for the three groups. This was particularly noticeable for the DM2 group with damaged retinas. The acircularity values were also slightly reduced with the final criterion in all groups. The FAZ areas with lower values showed slightly higher acircularity values. We also have a consistent and coherent set of segmentations with which to continue our research. Conclusions: Manual segmentations of FAZ are generally carried out with little attention to the consistency of the measurements. A novel criterion for segmenting the FAZ allows segmentations made by different observers to be more similar.

1 April 2014 in Optics and Lasers in Engineering
Verified
Journal Article
Closed access
FSF. Javier Salgado-Remacha
F. Javier Salgado-Remacha
JSJosé Antonio Sánchez-Martín
José Antonio Sánchez-Martín
Eusebio BernabeuEusebio Bernabeu
Eusebio Bernabeu