Jae Min Shin

Prof. Jae Min Shin

Gangnam Severance Hospital, Yonsei University College of MEdicine
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Journal of Thoracic Disease
Verified
Journal Article
Open access
PDF file
JSJae Min Shin
Jae Min Shin
TKTae Hoon Kim
Tae Hoon Kim
JKJi Young Kim
Ji Young Kim
CPChul Hwan Park
Chul Hwan Park
Background: Our study assessed the reliability of non-gated, non-contrast chest computed tomography (NCCT) (with high pitch, wide coverage, and fast gantry rotation time, reconstructed at various slice thicknesses), compared with the electrocardiography (ECG)-gated calcium scoring cardiac computed tomography (CaCT), for quantifying coronary artery calcification (CAC). Methods: Patients aged ≥50 years who required clinical NCCT were prospectively enrolled. All CT scans were performed with 256-detector rows; z-axis coverage, 8 cm; pitch, 1.5; and gantry rotation time, 280 ms (table feed, 42.86 cm/s). NCCT was followed by ECG-gated CaCT. The NCCT images were reconstructed at 0.625-, 1.25-, and 2.5-mm slice intervals. The CAC score was calculated on four sets of CT images with a commercially available software using the Agatston method. The CAC scores were divided into four standard Agatston scoring categories (Agatston scores: 0, 1–100, 101–400, and >400). The inter-observer and inter-technique agreements were evaluated for the CAC scores. Results: Twenty-six patients (M:F, 14:12; mean age, 66.04±6.97 years) were evaluated. Agatston scores showed near-perfect correlation between CaCT and NCCT for each slice thickness. On Bland-Altman analysis, the mean differences of Agatston scores between CaCT and NCCT (slice thicknesses: 0.625, 1.25, and 2.5 mm) were 37.54, 6.67, and −41.04, respectively. Inter-technique concordance was high for the four Agatston scoring categories with linear-weighted kappa values of 0.599, 0.609, and 0.597 for NCCT (slice thicknesses: 0.625, 1.25, and 2.5 mm, respectively). NCCT with 1.25-mm slice thickness showed the strongest correlation with CaCT. Conclusions: CAC quantification with NCCT using a wide detector, high pitch, and high temporal resolution scanning modes correlates very highly with ECG-gated CaCT, and 1.25-mm slice thickness NCCT images are more reliable than other NCCT images.

1 January 2022 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
MCMin Jae Cha
Min Jae Cha
CKCherry Kim
Cherry Kim
CPChan Ho Park
Chan Ho Park
YHYoo Jin Hong
Yoo Jin Hong
JSJae Min Shin
Jae Min Shin
CPChul Hwan Park
Chul Hwan Park
Cha MJ, et al. Korean J Radiol. 2022 May;23:e36. https://doi.org/10.3348/kjr.2021.0815

1 August 2020 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
JSJae Min Shin
Jae Min Shin
ECEui-Young Choi
Eui-Young Choi
CPChul Hwan Park
Chul Hwan Park
KHKyunghwa Han
Kyunghwa Han
TKTae Hoon Kim
Tae Hoon Kim
Objective: To compare native and post-contrast T1 mapping with late gadolinium enhancement (LGE) imaging for detecting and measuring the microvascular obstruction (MVO) area in reperfused acute myocardial infarction (MI). Materials and Methods: This study included 20 patients with acute MI who had undergone 1.5T cardiovascular magnetic resonance imaging (CMR) after reperfusion therapy. CMR included cine imaging, LGE, and T1 mapping (modified look-locker inversion recovery). MI size was calculated from LGE by full-width at half-maximum technique. MVO was defined as an area with low signal intensity (LGE) or as a region of visually distinguishable T1 values (T1 maps) within infarcted myocardium. Regional T1 values were measured in MVO, infarcted, and remote myocardium on T1 maps. MVO area was measured on and compared among LGE, native, and post-contrast T1 maps. Results: The mean MI size was 27.1 +/- 9.7% of the left ventricular mass. Of the 20 identified MVOs, 18 (90%) were detected on native T1 maps, while 10 (50%) were recognized on post-contrast T1 maps. The mean native T1 values of MVO, infarcted, and remote myocardium were 1013.5 +/- 58.5, 1240.9 +/- 55.8 (p < 0.001), and 1062.2 +/- 55.8 ms (p = 0.169), respectively, while the mean post-contrast T1 values were 466.7 +/- 26.8, 399.1 +/- 21.3, and 585.2 +/- 21.3 ms, respectively (p < 0.001). The mean MVO areas on LGE, native, and post-contrast T1 maps were 134.1 +/- 81.2, 133.7 +/- 80.4, and 117.1 +/- 53.3 mm(2), respectively. The median (interquartile range) MVO areas on LGE, native, and post-contrast T1 maps were 128.0 (58.1-215.4), 110.5 (67.7-227.9), and 143.0 (76.7-155.3) mm(2), respectively (p = 0.002). Concordance correlation coefficients for the MVO area between LGE and native T1 maps, LGE and post-contrast T1 maps, and native and post-contrast T1 maps were 0.770, 0.375, and 0.565, respectively. Conclusion: MVO areas were accurately delineated on native T1 maps and showed high concordance with the areas measured on LGE. However, post-contrast T1 maps had low detection rates and underestimated MVO areas. Collectively, native T1 mapping is a useful tool for detecting MVO within the infarcted myocardium.

8 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SLSun Yong Lee
Sun Yong Lee
TKTae Hoon Kim
Tae Hoon Kim
KHKyunghwa Han
Kyunghwa Han
JSJae Min Shin
Jae Min Shin
JKJi Young Kim
Ji Young Kim
CPChul Hwan Park
Chul Hwan Park
Rationale and Objectives: This study aimed to evaluate the feasibility of assessment using the coronary artery calcium score (CACS) in dual-energy chest computed tomography (CT). Materials and Methods: We prospectively enrolled 30 patients (19 male, 11 female; mean age, 63.73 ± 9.40 years) who clinically required contrast-enhanced chest CT. The patients underwent electrocardiogram-gated cardiac calcium-scoring CT with a slice thickness of 2.5 mm followed by a sequentially non-gated contrast-enhanced dual-energy chest CT using 140/80 fast kVp switching technology with slice thicknesses of 1.25 mm and 2.5 mm. Virtual unenhanced (VUE) images were then reconstructed from the dual-energy CT using the material suppressed iodine (MSI) technique. Results: The mean heart rates were 63.33 ± 12.01 beats per minute. The mean CACS on the coronary calcium-scoring CT was 361.1 ± 435.5, and CACSs of the VUE images were 76.8 ± 128.6 (2.5 mm slice) and 108.7 ± 165.1 (1.25 mm slice). The correlation coefficients of CACS between the coronary calcium-scoring CT with the VUE 2.5 mm and 1.25 mm images were 0.888 and 0.904, respectively. The inter-observer agreements for the calcium score measurement between the calcium-scoring CT, VUE 2.5 mm, and VUE 1.25 mm were 1.000, 0.999, and 1.000, respectively. Conclusions: In conclusion, assessment of CACS using dual-energy chest CT might be feasible when using MSI virtual unenhanced dual-energy chest CT images with a slice thickness of 1.25 mm.

27 August 2021 in Journal of the Korean Society of Radiology
Verified
Journal Article
Open access
PDF file
SKSo Jung Ki
So Jung Ki
CPChul Hwan Park
Chul Hwan Park
KHKyunghwa Han
Kyunghwa Han
JSJae Min Shin
Jae Min Shin
JKJi Young Kim
Ji Young Kim
TKTae Hoon Kim
Tae Hoon Kim
기소정, et al. J Korean Soc Radiol. 2021 Nov;82(6):1493-1504. https://doi.org/10.3348/jksr.2020.0156

1 January 2023 in Journal of the Korean Society of Radiology
Verified
Journal Article
Open access
PDF file
KJKwang Nam Jin
Kwang Nam Jin
BNBo Da Nam
Bo Da Nam
JSJae Min Shin
Jae Min Shin
SHSung Ho Hwang
Sung Ho Hwang
진광남, et al. J Korean Soc Radiol. 2023 Jul;84:e73. https://doi.org/10.3348/jksr.2022.0110