Habtamu Bayera Madessa

Dr. Habtamu Bayera Madessa

OsloMet - Oslo Metropolitan University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
MRMehrdad Rabani
Mehrdad Rabani
HMHabtamu Bayera Madessa
Habtamu Bayera Madessa
Natasa NordNatasa Nord
Natasa Nord
Simultaneous satisfaction of both thermal and visual comfort in buildings may be a challenging task. Therefore, this paper suggests a comprehensive framework for the building energy optimization process integrating computational fluid dynamics (CFD) daylight simulations. A building energy simulation tool, IDA Indoor Climate and Energy (IDA-ICE), was coupled with three open-source tools including GenOpt, OpenFOAM, and Radiance. In the optimization phase, several design variables i.e., building envelope properties, fenestration parameters, and Heating, Ventilation and Air-Conditioning (HVAC) system set points, were selected to minimize the total building energy use and simultaneously improve thermal and visual comfort. Two different scenarios were investigated for retrofitting of a generic office building located in Oslo, Norway. In the first scenario a constant air volume (CAV) ventilation system with a local radiator in each zone was used, while an all-air system equipped with a demand control ventilation (DCV) was applied in the second scenario. Findings showed that, compared to the reference design, significant reduction of total building energy use, around 77% and 79% in the first and second scenarios, was achieved respectively, and thermal and visual comfort conditions were also improved considerably. However, the overall thermal and visual comfort satisfactions were higher when all-air system was applied.

29 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
ANAbdulbasit Nasir
Abdulbasit Nasir
EDEdessa Dribssa
Edessa Dribssa
MGMisrak Girma
Misrak Girma
HMHabtamu Bayera Madessa
Habtamu Bayera Madessa
The high price of purpose-made turbines always represents an active challenge when utilizing pico- and micro-hydropower resources. Pumps as turbines (PATs) are a promising option to solve the problem. However, the selection of a suitable pump for a specific site and estimating its performance in the reverse mode are both major problems in the field. Therefore, this paper aims to develop generic mathematical correlations between the site and the pump hydraulic data, which can be used to select the optimal operation of the pump as a turbine. A statistical model and the Pearson correlation coefficient formula were employed to generate correlations between the flow rate and the head of the pumps with the sites. Then, Ansys CFX, coupled with SST k-ω and standard k-ε turbulence models, was used to analyze the performance of the PAT. The analysis was conducted in terms of flow rate, pressure head, efficiency, and power output. The numerical results were validated using an experimental test rig. The deviations of the proposed correlations from the statistical model were found to be in the range of −0.2% and 1.5% for the flow rate and ±3.3% for the pressure head. The obtained numerical outputs using the standard k-ε turbulence model strongly agreed with the experimental results, with variations of −1.82%, 2.94%, 2.88%, and 1.76% for the flow rate, head, power, and efficiency, respectively. The shear stress transport (SST) k-ω turbulence model showed relatively higher deviations when compared to standard k-ε. From the results, it can be concluded that the developed mathematical correlations significantly contribute to selecting the optimal operation of the pump for power-generating applications. The adopted numerical procedure, selected mesh type, turbulence model, and physics setup provided good agreement with the test result. Among the two turbulence models, the standard k-ε performs better in estimating the pressure head, output power, and efficiency of the PAT with less than 3% errors when compared to experimental results.

30 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
HTHakan Ibrahim Tol
Hakan Ibrahim Tol
HMHabtamu Bayera Madessa
Habtamu Bayera Madessa
This review presents a comprehensive examination of recent advancements and findings related to return-temperature reduction in District Heating (DH) systems, with a focus on enhancing overall system efficiency at end-user sites. The review categorizes and clarifies various return-temperature reduction techniques, emphasizing aspects such as building energy performance, heat emitters, thermostatic radiator valves, and substation units. One shall note that return temperature is not a parameter that can be directly controlled within a DH system; instead, it is influenced indirectly by adjusting various system parameters throughout the design, commissioning, operation, and control phases. Key insights include the direct impact of heat demand on return temperatures; the pivotal role of indoor heating systems in optimizing thermal energy use in relation to heat demand; the significance of thermostatic radiator valves in regulating heat output and maintaining low return temperatures; the advantages of ventilation radiators and add-on fans in enhancing radiator efficiency; the necessity for effective substation operation to improve system cooling capacity; and the critical role of operational control strategies in achieving optimal system performance. These findings underscore the need for integrated approaches in DH system design and operation to achieve lower return temperatures and improve overall system efficiency.

10 March 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HTHakan Ibrahim Tol
Hakan Ibrahim Tol
HMHabtamu Bayera Madessa
Habtamu Bayera Madessa
This review paper provides a comprehensive examination of current strategies and technical considerations for reducing return temperatures in district heating (DH) systems, aiming to enhance the utilization of available thermal energy. Return temperature, a parameter indirectly influenced by various system-level factors, cannot be adjusted directly but requires careful management throughout the design, commissioning, operation, and control phases. This paper explores several key factors affecting return temperature, including DH network, heat storage, and control strategies as well as the return temperature effect on the heat source. This paper also considers the influence of non-technical aspects, such as pricing strategies and maintenance practices, on system performance. The discussion extends to the complex interplay between low return temperatures and temperature differences, and between operational temperature schemes and economic considerations. Concluding remarks emphasize the importance of adopting a holistic approach that integrates technical, operational, and economic factors to improve DH system efficiency. This review highlights the need for comprehensive system-level optimization, effective management of system components, and consideration of unique heat production characteristics. By addressing these aspects, this study provides a framework for advancing DH system performance through optimized return temperature management.

6 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Andreas AamodtAndreas Aamodt
Andreas Aamodt
Arnab ChaudhuriArnab Chaudhuri
Arnab Chaudhuri
HMHabtamu Bayera Madessa
Habtamu Bayera Madessa
TVTor Arvid Vik
Tor Arvid Vik
Phase change material (PCM) is an attractive solution for improvement of thermal performance in buildings, and have excited a vast amount of research in recent years. There are however practical challenges with ensuring adequate phase transitions of the PCM to exploit the passive heat storage benefits. Night ventilation (NV) with free cooling have surfaced as one of the most promising methods to properly utilize PCMs and maximize energy savings. This work deals with a novel spackling compound enhanced with microencapsulated PCM. The product is intended for use at inner walls and ceiling surfaces of buildings and is suited for new and retrofitting building applications. Ensuing former experimental studies, a validated simulation model is developed and used to study the PCM with natural and hybrid NV strategies in an office building during summer conditions in Oslo, Norway. Cooling load reduction and energy savings are analyzed with varying air flow rates of 0.5–5 air changes per hour (ACH) and 2–4 mm PCM layer thickness. It is shown how increasing air flow rates and PCM thickness greatly enhances energy performance, but at a diminishing rate. Although the NV alone can reduce the cooling load by 11.5% at 1 ACH, 40.2% at 3 ACH and 59.8% at 5 ACH, one can achieve further reduction up to 19.5%, 78.2% and 95.5% for the respective ACHs with 4 mm PCM. The natural NV provides more energy savings compared to the hybrid strategy. As energy requirement by fans increases with the increase of air flow rates in the hybrid strategy, the energy savings eventually start to reduce. The hybrid strategy can save 38% energy at most with 3 ACH, and the savings is increased to 50% with the inclusion of 4 mm PCM. On the other hand, the natural strategy saves 56% of energy at the same air flow rate, and 69% with 4 mm of PCM.

9 January 2025
Verified
Book Chapter
Open access
PDF file
ELEmma Zheng Liang
Emma Zheng Liang
HMHabtamu Bayera Madessa
Habtamu Bayera Madessa
It is known that the built environment is one of the largest contributors to greenhouse gas emissions. In the building sectors, significant efforts have been made to reduce emission associated with energy use in buildings and construction materials. However, the process related to integrated technical building installations (ITB) is not well addressed. The study includes a case study for zero-emission educational building. By examining case studies, best practices, and emerging problems, this research sheds light on the transformative power of integrated technical building installations in optimizing energy efficiency and consequently reducing carbon footprints. The findings underscore the need for a multidisciplinary approach, collaboration among stakeholders, and the integration of best practices in the realization of zero-emission buildings should be applied at the very beginning of building process.