This article introduces a basic LED control using the USB6001 hardware, which is a LabVIEW product. It may be thought of as an extension device for real-time testing of simulation results. LabVIEW2014 is the software used. TCP is the communication technique, which has already been incorporated in LabVIEW via one of the communication modules. It might also be done on the same platform. There are two objects in this article, a server and a client, that may transport data or messages between these two applications. The Transmission Control Protocol governs the transmission process.
The main contribution of this article is creating synergy between subjects; this means that students use the same graphical tool in several subjects. So far, the bond graph has not been used in control theory, but it is the “native language” of mechatronics engineers, so we would like to introduce it into the teaching of control theory. The bond graph method is proposed as a novel teaching method to teach mechatronics subjects in the paper. The bond graph is a graphical alternative to ordinary differential equations from a mathematical standpoint. Traditionally, control theory employs ordinary differential equations, as they are familiar to control theorists. However, mathematically, both approaches are equivalent but require a slightly different approach in their application. This article highlights the mathematical similarities between the two approaches while emphasizing the distinctions in graphical representation. Another contribution is that the PID and sliding mode controller are represented using the bond graph method. In the meantime, through the use of practical examples, we effectively illustrate how the same problem can be solved using either approach. In the training materials, the PID controller and an adaptive robust sliding mode controller (ARSMC) with the bond graph are utilized as examples to demonstrate synergy in mechatronics. Finally, we present proof that mechatronic engineers achieve superior outcomes when utilizing the bond graph approach, based on test results from undergraduate students.
Aggregate building indicators can obscure substantial differences in electrical demand and thermal operation among monitored spaces. This case study examined 89 days of one-minute building management system (BMS) and smart-meter records from a multi-zone university building. Routine data-quality screening was combined with physical interpretation and task requirements to determine how the available channels could be used in the exploratory analyses. The resulting map specifies each channel’s permitted use and any associated monitoring priority. Meter TR1 was selected as the primary monitored-load proxy, whereas Meter G was retained for comparative diagnosis. Primary energy analysis used 59 fully observed TR1 days without imputation or scaling. Sensitivity analyses used all 61 days meeting the 90% and 95% completeness thresholds and reported their energy values as available-minute energy aggregates. Across the 59 fully observed days, weekday energy exceeded weekend energy, and complete 24 h TR1 energy was strongly inversely associated with daily mean outdoor temperature (Spearman ). Of the 21 monitored spaces, five were warm-biased, four were cold-biased, and 12 were near setpoint. Within the observed winter-to-shoulder-season period, the data supported exploratory load and zone-temperature modeling. The combined assessment established record eligibility and channel use in this incomplete real-world export, and it identified priorities for later monitoring.