Ville Kolehmainen

Prof. Dr. Ville Kolehmainen

Department of Applied Physics, University of Eastern Finland, FI-70211 Kuopio, Finland
orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2000 in Inverse Problems
Verified
Journal Article
Closed access
JKJari P Kaipio
Jari P Kaipio
Ville KolehmainenVille Kolehmainen
Ville Kolehmainen
ESErkki Somersalo
Erkki Somersalo
MVMarko Vauhkonen
Marko Vauhkonen

13 January 2006 in Inverse Problems
Verified
Journal Article
Closed access
SAS R Arridge
S R Arridge
JKJ P Kaipio
J P Kaipio
Ville KolehmainenVille Kolehmainen
Ville Kolehmainen
MSM Schweiger
M Schweiger
ESE Somersalo
E Somersalo
MVM Vauhkonen
M Vauhkonen

1 January 1999 in Inverse Problems
Verified
Journal Article
Closed access
PDF file
JKJ P Kaipio
J P Kaipio
Ville KolehmainenVille Kolehmainen
Ville Kolehmainen
MVM Vauhkonen
M Vauhkonen
ESE Somersalo
E Somersalo

13 September 2010 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
ANAntti Nissinen
Antti Nissinen
Ville KolehmainenVille Kolehmainen
Ville Kolehmainen
JKJari P. Kaipio
Jari P. Kaipio
Electrical impedance tomography is a highly unstable problem with respect to measurement and modeling errors. This instability is especially severe when absolute imaging is considered. With clinical measurements, accurate knowledge about the body shape is usually not available, and therefore an approximate model domain has to be used in the computational model. It has earlier been shown that large reconstruction artefacts result if the geometry of the model domain is incorrect. In this paper, we adapt the so-called approximation error approach to compensate for the modeling errors caused by inaccurately known body shape. This approach has previously been shown to be applicable to a variety of modeling errors, such as coarse discretization in the numerical approximation of the forward model and domain truncation. We evaluate the approach with a simulated example of thorax imaging, and also with experimental data from a laboratory setting, with absolute imaging considered in both cases. We show that the related modeling errors can be efficiently compensated for by the approximation error approach. We also show that recovery from simultaneous discretization related errors is feasible, allowing the use of computationally efficient reduced order models.

7 May 2003 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
SSS Siltanen
S Siltanen
Ville KolehmainenVille Kolehmainen
Ville Kolehmainen
SRS J Rvenp
S J Rvenp
JKJ P Kaipio
J P Kaipio
PKP Koistinen
P Koistinen
ESE Somersalo
E Somersalo
In x-ray tomography, the structure of a three-dimensional body is reconstructed from a collection of projection images of the body. Medical CT imaging does this using an extensive set of projections from all around the body. However, in many practical imaging situations only a small number of truncated projections are available from a limited angle of view. Three-dimensional imaging using such data is complicated for two reasons: (i) typically, sparse projection data do not contain sufficient information to completely describe the 3D body, and (ii) traditional CT reconstruction algorithms, such as filtered backprojection, do not work well when applied to few irregularly spaced projections. Concerning (i), existing results about the information content of sparse projection data are reviewed and discussed. Concerning (ii), it is shown how Bayesian inversion methods can be used to incorporate a priori information into the reconstruction method, leading to improved image quality over traditional methods. Based on the discussion, a low-dose three-dimensional x-ray imaging modality is described.

1 November 1997 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
Ville KolehmainenVille Kolehmainen
Ville Kolehmainen
MVM Vauhkonen
M Vauhkonen
PKPasi A. Karjalainen
Pasi A. Karjalainen
JKJ P Kaipio
J P Kaipio
In electrical impedance tomography (EIT), difference imaging is often preferred over static imaging. This is because of the many unknowns in the forward modelling which make it difficult to obtain reliable absolute resistivity estimates. However, static imaging and absolute resistivity values are needed in some potential applications of EIT. In this paper we demonstrate by simulation the effects of different error components that are included in the reconstruction of static EIT images. All simulations are carried out in two dimensions with the so-called complete electrode model. Errors that are considered are the modelling error in the boundary shape of an object, errors in the electrode sizes and localizations and errors in the contact impedances under the electrodes. Results using both adjacent and trigonometric current patterns are given.