Christoph Wenisch

Dr. Christoph Wenisch


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
ATAnnemarie Tesch
Annemarie Tesch
CWChristoph Wenisch
Christoph Wenisch
KHKarl-Heinz Herrmann
Karl-Heinz Herrmann
JRJürgen R. Reichenbach
Jürgen R. Reichenbach
PWPaul Warncke
Paul Warncke
FMFrank Müller
Frank Müller

6 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
CWChristoph Wenisch
Christoph Wenisch
SESebastian Engel
Sebastian Engel
SGStephan Gräf
Stephan Gräf
FMFrank Müller
Frank Müller
We present a unique dual laser beam processing approach based on excited state absorption by structuring 200 nm thin zinc oxide films sputtered on fused silica substrates. The combination of two pulsed nanosecond-laser beams with different photon energies—one below and one above the zinc oxide band gap energy—allows for a precise, efficient, and homogeneous ablation of the films without substrate damage. Based on structuring experiments in dependence on laser wavelength, pulse fluence, and pulse delay of both laser beams, a detailed concept of energy transfer and excitation processes during irradiation was developed. It provides a comprehensive understanding of the thermal and electronic processes during ablation. To quantify the efficiency improvements of the dual-beam process compared to single-beam ablation, a simple efficiency model was developed.

14 March 2016 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
SESebastian Engel
Sebastian Engel
CWChristoph Wenisch
Christoph Wenisch
FMFrank Müller
Frank Müller
SGStephan Gräf
Stephan Gräf
The present study reports on a new photoacoustic (PA) measurement method that is suitable for the investigation of light induced absorption effects including e.g. excited state absorption. Contrary to the modulation of the radiation intensity used in conventional PA-methods, the key principle of this novel setup is based on the modulation of the induced absorption coefficient by light. For this purpose, a pump-probe setup with a pulsed pump laser beam and a continuous probe laser beam is utilized. In this regime, the potential influence of heat on the PA-signal is much smaller when compared to arrangements with pulsed probe beam and continuous pump beam. Beyond that, the negative effect of thermal lenses can be neglected. Thus, the measurement technique is well-suited for materials exhibiting a strong absorption at the pump wavelength. The quantitative analysis of the induced absorption coefficient was achieved by the calibration of the additional PA-signal caused by the continuous probe laser to the PA-signal resulting from the pulsed pump laser using thallium bromoiodide (KRS-5) as sample material.