Timmen Ludger

Dr. Timmen Ludger

Leibniz University Hannover
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2018 in Nature Physics
Verified
Journal Article
Closed access
PDF file
JGJacopo Grotti
Jacopo Grotti
SKSilvio Koller
Silvio Koller
SVStefan Vogt
Stefan Vogt
SHSebastian Häfner
Sebastian Häfner
USUwe Sterr
Uwe Sterr
Davide CalonicoDavide Calonico
Davide Calonico

18 June 2010 in Metrologia
Verified
Journal Article
Closed access
SMS Merlet
S Merlet
QBQ Bodart
Q Bodart
NMNicola Malossi
Nicola Malossi
ALA Landragin
A Landragin
FSF Pereira Dos Santos
F Pereira Dos Santos
Timmen LudgerTimmen Ludger
Timmen Ludger
We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universit\"at of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral comparison took place in the LNE watt balance laboratory and showed an agreement of 4.3 +/- 6.4 {\mu}Gal.

12 December 2017 in Journal of Geodesy
Verified
Journal Article
Open access
PDF file
HDHeiner Denker
Heiner Denker
Timmen LudgerTimmen Ludger
Timmen Ludger
CVChristian Voigt
Christian Voigt
SWStefan Weyers
Stefan Weyers
EPEkkehard Peik
Ekkehard Peik
GPGérard Petit
Gérard Petit
The frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching the one part in \(10^{18}\) level. Comparisons between earthbound clocks at rest must account for the relativistic redshift of the clock frequencies, which is proportional to the corresponding gravity (gravitational plus centrifugal) potential difference. For contributions to international timescales, the relativistic redshift correction must be computed with respect to a conventional zero potential value in order to be consistent with the definition of Terrestrial Time. To benefit fully from the uncertainty of the optical clocks, the gravity potential must be determined with an accuracy of about \(0.1\,\hbox {m}^{2}\,\hbox {s}^{-2}\), equivalent to about 0.01 m in height. This contribution focuses on the static part of the gravity field, assuming that temporal variations are accounted for separately by appropriate reductions. Two geodetic approaches are investigated for the derivation of gravity potential values: geometric levelling and the Global Navigation Satellite Systems (GNSS)/geoid approach. Geometric levelling gives potential differences with millimetre uncertainty over shorter distances (several kilometres), but is susceptible to systematic errors at the decimetre level over large distances. The GNSS/geoid approach gives absolute gravity potential values, but with an uncertainty corresponding to about 2 cm in height. For large distances, the GNSS/geoid approach should therefore be better than geometric levelling. This is demonstrated by the results from practical investigations related to three clock sites in Germany and one in France. The estimated uncertainty for the relativistic redshift correction at each site is about \(2 \times 10^{-18}\).

5 October 2012 in Metrologia
Verified
Journal Article
Closed access
ZJZ Jiang
Z Jiang
VPV Pálinkáš
V Pálinkáš
FAF E Arias
F E Arias
JLJ Liard
J Liard
SMSébastien Merlet
Sébastien Merlet
IRI Robinson
I Robinson
The 8th International Comparison of Absolute Gravimeters (ICAG2009) took place at the headquarters of the International Bureau of Weights and Measures (BIPM) from September to October 2009. It was the first ICAG organized as a key comparison in the framework of the CIPM Mutual Recognition Arrangement of the International Committee for Weights and Measures (CIPM MRA) (CIPM 1999). ICAG2009 was composed of a Key Comparison (KC) as defined by the CIPM MRA, organized by the Consultative Committee for Mass and Related Quantities (CCM) and designated as CCM.G-K1. Participating gravimeters and their operators came from national metrology institutes (NMIs) or their designated institutes (DIs) as defined by the CIPM MRA. A Pilot Study (PS) was run in parallel in order to include gravimeters and their operators from other institutes which, while not signatories of the CIPM MRA, nevertheless play important roles in international gravimetry measurements. The aim of the CIPM MRA is to have international acceptance of the measurement capabilities of the participating institutes in various fields of metrology. The results of CCM.G-K1 thus constitute an accurate and consistent gravity reference traceable to the SI (International System of Units), which can be used as the global basis for geodetic, geophysical and metrological observations of gravity. The measurements performed afterwards by the KC participants can be referred to the international metrological reference, i.e. they are SI-traceable. The ICAG2009 was complemented by a number of associated measurements: the Relative Gravity Campaign (RGC2009), high-precision levelling and an accurate gravity survey in support of the BIPM watt balance project. The major measurements took place at the BIPM between July and October 2009. Altogether 24 institutes with 22 absolute gravimeters (one of the 22 AGs was ultimately withdrawn) and nine relative gravimeters participated in the ICAG/RGC campaign. This paper is focused on the absolute gravity campaign. We review the history of the ICAGs and present the organization, data processing and the final results of the ICAG2009. After almost thirty years of hosting eight successive ICAGs, the CIPM decided to transfer the responsibility for piloting the future ICAGs to NMIs, although maintaining a supervisory role through its Consultative Committee for Mass and Related Quantities.

11 November 2016 in Metrologia
Verified
Journal Article
Closed access
PDF file
CVChristian Voigt
Christian Voigt
HDH Denker
H Denker
Timmen LudgerTimmen Ludger
Timmen Ludger
The latest generation of optical atomic clocks is approaching the level of one part in 10 18 in terms of frequency stability and uncertainty. For clock comparisons and the definition of international time scales, a relativistic redshift effect of the clock frequencies has to be taken into account at a corresponding uncertainty level of about 0.1 m 2 s −2 and 0.01 m in terms of gravity potential and height, respectively. Besides the predominant static part of the gravity potential, temporal variations must be considered in order to avoid systematic frequency shifts. Time-variable gravity potential components induced by tides and non-tidal mass redistributions are investigated with regard to the level of one part in 10 18 . The magnitudes and dominant time periods of the individual gravity potential contributions are investigated globally and for specific laboratory sites together with the related uncertainty estimates. The basics of the computation methods are presented along with the applied models, data sets and software. Solid Earth tides contribute by far the most dominant signal with a global maximum amplitude of 4.2 m 2 s −2 for the potential and a range (maximum-to-minimum) of up to 1.3 and 10.0 m 2 s −2 in terms of potential differences between specific laboratories over continental and intercontinental scales, respectively. Amplitudes of the ocean tidal loading potential can amount up to 1.25 m 2 s −2 , while the range of the potential between specific laboratories is 0.3 and 1.1 m 2 s −2 over continental and intercontinental scales, respectively. These are the only two contributors being relevant at a 10 −17 level. However, several other time-variable potential effects can particularly affect clock comparisons at the 10 −18 level. Besides solid Earth pole tides, these are non-tidal mass redistributions in the atmosphere, the oceans and the continental water storage.

3 June 2024 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
JGJ. Grotti
J. Grotti
INI. Nosske
I. Nosske
SKS.B. Koller
S.B. Koller
SHS. Herbers
S. Herbers
HDH. Denker
H. Denker
CLC. Lisdat
C. Lisdat
We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The 87Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of 3918.1(2.6)m2s−2 agrees with an independent geodetic determination of 3915.88(0.30)m2s−2. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of 27cm in height.