Vladimir Polužanski

Dr. Vladimir Polužanski

University of Belgrade School of Electrical Engineering
+1
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VPVladimir Polužanski
Vladimir Polužanski
UKUros Kovacevic
Uros Kovacevic
NEBOJSA BACANINNEBOJSA BACANIN
NEBOJSA BACANIN
Tarik RashidTarik Rashid
Tarik Rashid
SSSasa Stojanovic
Sasa Stojanovic
Bosko NikolicBosko Nikolic
Bosko Nikolic
The continuing increase in data processing power in modern devices and the availability of a vast amount of data via the internet and the internet of things (sensors, monitoring systems, financial records, health records, social media, etc.) enabled the accelerated development of machine learning techniques. However, the collected data can be inconsistent, incomplete, and noisy, leading to a decreased confidence in data analysis. The paper proposes a novel “judgmental” approach to evaluating the measurement uncertainty of the machine learning model that implements the dropout additive regression trees algorithm. The considered method uses the procedure for expressing the type B measurement uncertainty and the maximal value of the empirical absolute loss function of the model. It is related to the testing and monitoring of power equipment and determining partial discharge location by the non-iterative, all-acoustic method. The example uses the dataset representing the correlation of the mean distance of partial discharge and acoustic sensors and the temperature coefficient of the sensitivity of the non-iterative algorithm. The dropout additive regression trees algorithm achieved the best performance based on the highest coefficient of determination value. Most of the model’s predictions (>97%) fell into the proposed standard measurement uncertainty interval for both “seen” and “unseen” data.

12 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
VPVladimir Polužanski
Vladimir Polužanski
NKNenad Kartalović
Nenad Kartalović
Bosko NikolicBosko Nikolic
Bosko Nikolic
In this paper, the influence of the variation in transformer oil temperature on the accuracy of the all-acoustic non-iterative method for partial discharge location in a power transformer is researched. The research can improve power transformers’ testing and monitoring, particularly given the large transformer oil temperature variations during real-time monitoring. The research is based on quantifying the contribution of oil temperature to the standard combined measurement uncertainty of the non-iterative algorithm by using analytical, statistical, and Monte Carlo methods. The contribution can be quantified and controlled. The contribution varied significantly with different mutual placements of partial discharge and acoustic sensors. The correlation between the contribution and the mean distance between partial discharge and acoustic sensors was observed. Based on these findings, the procedure to quantify and control the contribution in practice was proposed. The procedure considers the specificity of the method’s mathematical model (the assumption that the oil temperature is constant), the non-iterative algorithm’s nonlinearity, and the large variations in transformer oil temperature. Existing studies did not consider the significant effect of the oil temperature on the combined measurement uncertainty of partial discharge location influenced by those phenomena. The research is limited to partial discharge located in the transformer oil.

26 December 2016 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
BDBranislav V. Djokic
Branislav V. Djokic
HPHarold Parks
Harold Parks
NWNicholas Wise
Nicholas Wise
DNDragana Naumovic-Vukovic
Dragana Naumovic-Vukovic
SSSlobodan P. Skundric
Slobodan P. Skundric
VPVladimir Polužanski
Vladimir Polužanski
A comparison of two systems based on different methods for calibration of current transformers at several different transformation ratios, burdens, and power frequencies of 60 Hz and 50 Hz is performed at the National Research Council of Canada. The obtained discrepancies in ratio and phase errors are within 5 μA/A and μrad, respectively, for small test currents and less for larger test currents.

1 January 2018 in FME Transactions
Verified
Journal Article
Open access
PDF file
VPVladimir Polužanski
Vladimir Polužanski
UKUroš D. Kovačević
Uroš D. Kovačević
Bosko NikolicBosko Nikolic
Bosko Nikolic
This article investigates the all-acoustic method for partial discharge localization in a power transformer. This method is based on mathematical model that uses multilateration with Time Difference of Arrival (TDOA) principle and non-itterative mathematical algorithm. In this model, it is assumed that acoustic signal propagates only through transformer oil and that the velocity of acoustic signal is constant. Acoustic signal velocity is largely dependent on transformer oil temperature meaning that oil temperature is also considered to be constant. In reality if we look from the perspective of physics, thermo dynamics of fluids, transformer construction etc. this approximation is enormous. Therefore, influence of power transformer oil temperature change (velocity of acoustic signal change) on the accuracy of this method is investigated. For that purpose special algorithm is designed and implemented in Visual C# programming language. Based on conducted simulations, further knowledge is gained about interaction between transformer oil temperature and placement of acoustic sensors. This interaction produced significant disparity in noniterative algorithm's accuracy for different sensor positions with oil temperature change. In order to fully take advantage of noticed interaction, certain steps for further research and development are proposed.

1 January 2019 in Nuclear Technology and Radiation Protection
Verified
Journal Article
Open access
PDF file
VPVladimir Polužanski
Vladimir Polužanski
AŽAleksandar D. Žigić
Aleksandar D. Žigić
DKDragan S. Kovačević
Dragan S. Kovačević
Bosko NikolicBosko Nikolic
Bosko Nikolic
This paper presents a novel non-iterative algorithm for charge particle localization in a spark chamber. Its performance is evaluated by computer simulations using the Monte Carlo simulation method and compared with the performance of an appropriate iterative algorithm. It is found that the proposed non-iterative algorithm performs significantly better, is easier to implement and requires less computational resources than the iterative algorithm.

29 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
NMNikola Miladinovic
Nikola Miladinovic
FKFilip Kilibarda
Filip Kilibarda
URUros Radoman
Uros Radoman
VPVladimir Polužanski
Vladimir Polužanski
VRVladimir Radovanović
Vladimir Radovanović
Reliable operation of hydro turbine-generator units (HTGUs) is central to safe, flexible, and efficient hydropower generation. State-of-the-art approaches to condition monitoring, fault diagnosis, and early fault detection increasingly rely on artificial intelligence (AI)-driven methods. However, labeled fault data remain scarce and industrial validation of these AI methods remains limited. This paper presents a systematic, algorithm-focused review of predictive maintenance (PdM) for HTGUs. Using a Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)-guided literature search, we map data-driven and AI-enabled methods from classical machine learning through deep Autoencoders and hybrids to Transformers and state-space models (SSMs), and we compare them with respect to their interpretability, data requirements, and industrial deployability. Relative to plant-wide sensing surveys and generator-centric AI reviews, the contribution is an HTGU-wide assessment of which method families are validated on operational plants versus rotating-machinery benchmarks. Across the reviewed studies, several general patterns emerge: hydropower-specific work is dominated by unsupervised anomaly detection, classical machine learning approaches remain a strong, plant-validated baseline, and high accuracies of recent Transformer/SSM architectures should be interpreted as architectural potential on related assets, not as demonstrated HTGU deployability. We translate the identified gaps into a short-/medium-/long-term roadmap toward transferable, explainable, and industrially validated PdM.