Xiaocong Li

Xiaocong Li


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2020 in IEEE Access
Verified
Journal Article
Open access
俊徐俊华 徐
俊华 徐
XLXiaocong Li
Xiaocong Li
HLHui Liu
Hui Liu
XMXuanren Meng
Xuanren Meng
In this paper, the fractional-order modeling and analysis of a three-phase voltage source PWM rectifier (VSR) are researched considering the fractional-order characteristics of actual inductors and capacitors. While the Caputo fractional calculus operator is used to describe the fractional-order characteristics of an inductor and a capacitor, the fractional-order model of a three-phase VSR is established in the three-phase static coordinate system. With the coordinate transformation, the fractional-order model is expressed in the two-phase static coordinate system and in the synchronous rotation coordinate system, respectively. Simulation results verify the effectiveness of the established models, and indicate that the fractional-order models can describe the operating characteristics of a three-phase VSR more accurately. Besides, compared with the traditional integer-order three-phase VSRs, the three-phase VSRs which contain the fractional-order inductors and the fractional-order capacitor can present better static and dynamic performance indexes (such as smaller overshoot and shorter regulation time) by appropriately selecting the orders of the inductors and the capacitor.

9 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
XLXiaocong Li
Xiaocong Li
XCXin Chen
Xin Chen
Due to the nonlinear and nonminimum phase characteristics of the buck-boost converter, the design of its controller has always been a challenging problem. In this paper, a multi-index feedback linearization control strategy is proposed to design the controller of the buck-boost converter. Firstly, by constructing an appropriate output function, the original nonlinear system is mapped into a combination of a linear subsystem and a nonlinear subsystem. Then, according to the structural characteristics of these two subsystems, the linear optimal control theory is adopted for the control design of the linear subsystem to make it have a good output performance, while for the nonlinear subsystem, the coefficient of the output function is adjusted to ensure its stability. Finally, based on the Hartman–Grobman theorem, the internal mechanism and coefficient adjustment basis of the proposed method are revealed; that is, by adjusting the coefficient of the output function and the feedback coefficient of the linear control law, the poles of the system are configured to achieve the purpose of adjusting the static and dynamic performance of the system. The simulation results show the feasibility and superiority of using the multi-index feedback linearization control strategy to design the nonlinear control law of the buck-boost converter.

12 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
Muhammad Ahmad KhanMuhammad Ahmad Khan
Muhammad Ahmad Khan
XLXiaocong Li
Xiaocong Li
MYMuhammad Zain Yousaf
Muhammad Zain Yousaf
AMAli Mustafa
Ali Mustafa
MWMingshuo Wei
Mingshuo Wei
The purpose of this study is to improve the P-I controllers of the voltage-source converters (VSC)-based multiterminal high voltage direct-current (MT-HVDC) networks. Since the VSCs are the non-linear elements of the MT-HVDC stations, the classical optimization methods, which approximately implement the linear model to optimize the P-I controllers of the VSCs, do not generate optimal results. Therefore, this paper presents a novel technique to optimize the VSC-based MT-HVDC grids’ P-I controllers by embedding the artificial bee colony (ABC) algorithm. The voltage-droop control method is employed at on-shore grids to ensure the active and reactive power balance within MT-HVDC networks. During an evaluation, achieved via a detailed four-terminal MT-HVDC model designed in PSCAD/EMTDC, the improved results obtained under different dynamic situations such as unbalance wind power generation, change in load demand at the on-shore side grids, and eventual VSC disconnection, respectively.

25 February 2016 in The Canadian Journal of Chemical Engineering
Verified
Journal Article
Closed access
PDF file
FZFang Zhang
Fang Zhang
XLXiaocong Li
Xiaocong Li
YTYaocun Tang
Yaocun Tang
XGXiaoqiang Gao
Xiaoqiang Gao
LXli Xu
li Xu
GLguoji Liu
guoji Liu

18 November 2018 in IEEJ Transactions on Electrical and Electronic Engineering
Verified
Journal Article
Closed access
PDF file
SLSong Liu
Song Liu
XLXiaocong Li
Xiaocong Li
DCDengyi Chen
Dengyi Chen

20 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
XYXIA YUANYANG
XIA YUANYANG
XLXiaocong Li
Xiaocong Li
ZLZhili Liu
Zhili Liu
YLYuan Liu
Yuan Liu
The timely discovery of low-frequency oscillations in power systems and accurate identification of their modal parameters is critical in numerous applications. Therefore, we investigated the feasibility of using multi-channel signals and established a relative theory. An algorithm based on the underdetermined blind source separation (UBSS) algorithm was proposed using this theory. First, the energy ratio function was used to determine the fault occurrence time. Then, the Bayesian information criterion was used to estimate the number of fault sources, and the boundary conditions were set to determine the number of fault sources. Next, the UBSS algorithm was used to analyze raw data, extract individual components that characterize faults, and subsequently measure low-frequency oscillation modal parameters through the Hilbert transform. Finally, the fast independent component analysis (FastICA) algorithm was used to separate noise signal from raw data. This separation considerably reduced noise disturbance and ensured the stability of the proposed method. Model simulation was conducted in MATLAB and experimental measurement revealed that the proposed method effectively reduced noise disturbance and could be applied to conditions with considerable disturbance.