Purpose: Stargardt disease (STGD1) is an autosomal recessive retinopathy, caused by mutations in the retina-specific ATP-binding cassette transporter (ABCA4) gene. To establish the mutational spectrum and to assess effects of selected deep intronic and common genetic variants on disease, we performed a comprehensive sequence analysis in a large cohort of German STGD1 patients. Methods: DNA samples of 335 STGD1 patients were analyzed for ABCA4 mutations in its 50 coding exons and adjacent intronic sequences by resequencing array technology or next generation sequencing (NGS). Parts of intron 30 and 36 were screened by Sanger chain-terminating dideoxynucleotide sequencing. An in vitro splicing assay was used to test selected variants for their splicing behavior. By logistic regression analysis we assessed the association of common ABCA4 alleles while a multivariate logistic regression model calculated a genetic risk score (GRS). Results: Our analysis identified 148 pathogenic or likely pathogenic mutations, of which 48 constitute so far unpublished ABCA4-associated disease alleles. Four rare deep intronic variants were found once in 472 alleles analyzed. In addition, we identified six risk-modulating common variants. Genetic risk score estimates suggest that defined common ABCA4 variants influence disease risk in carriers of a single pathogenic ABCA4 allele. Conclusions: Our study adds to the mutational spectrum of the ABCA4 gene. Moreover, in our cohort, deep intronic variants in intron 30 and 36 likely play no or only a minor role in disease pathology. Of note, our findings demonstrate a possible modifying effect of common sequence variants on ABCA4-associated disease.
Currently, electroretinograms (ERGs) are mainly recorded while using flashes as stimuli. In this review, we will argue that strong flashes are not ideal for studying visual information processing. ERG responses to periodic stimuli may be more strongly associated with the activity of post-receptoral neurons (belonging to different retino-geniculate pathways) and, therefore, be more relevant for visual perception. We will also argue that the use of periodic stimuli may be an attractive addition to clinically available retinal electrophysiological methods.
6 January 2017 in Journal of the Optical Society of America A
We evaluated a technique for measuring temporal contrast sensitivities to sine-wave modulation driven by S-cones and rods in the perifovea using triple silent substitution. Isolating stimuli for S-cones and rods were created using an eight-channel, four-primary LED stimulator that has been validated before. Sensitivities were measured at 10 different temporal frequencies between 1 and 28 Hz in three normal observers at 14 different retinal illuminances between 0.07 and 587 photopic troland (phot Td) and at three different retinal illuminances over the same range in one S-cone monochromat. The technique was further validated by measuring bleaching adaptation in two normal subjects, demonstrating sufficient isolation in rods. Good isolation was apparent from the differences in the temporal contrast sensitivity functions and the sensitivity-versus-retinal illuminance functions between S-cones and rods, and also from the results in the S-cone monochromats and the delayed recovery of rod sensitivities after bleaching. The results will help to determine optimal stimulus conditions in future studies. The results in the S-cone monochromat demonstrate the potential clinical value of our protocol.
15 September 2016 in Journal of the Optical Society of America A
We established a protocol using a well-established LED stimulator to measure temporal contrast sensitivities driven by sine-wave modulation of L- and M-cones in the perifovea using triple silent substitution. The stimulus was presented in an annular field (2° inner diameter, 13° outer diameter). We validated this technique by studying the contrast sensitivity of three color normal observers at 10 different temporal frequencies (between 1 and 28 Hz) over a large range of retinal illuminances (between 0.07 and 587 phot Td), spanning the complete mesopic range. In one subject, sensitivities to counterphase modulation of L- and M-cones and in-phase modulation of L, M, and S-cones were additionally measured, which putatively reflected the parvo- and magnocellular retinogeniculate pathways, respectively. Furthermore, we performed measurements of temporal contrast sensitivities as a function of frequency at 294 phot Td in two protanopes, in two deuteranopes, and in one subject with S-cone monochromacy. Quality of isolation was satisfactory and we were able to reproduce known physiological patterns of temporal vision, such as the typical temporal contrast sensitivity functions of the L- and M-cone, the parvo- and magnocellular retinogeniculate pathways, as well as the light adaptation curves. These results will help determine optimal stimulus conditions in future studies. Results from the dichromats and the S-cone monochromat also support the quality of isolation of our protocol and underpin its potential clinical value.
To psychophysically determine macular pigment optical density (MPOD) employing the heterochromatic modulation photometry (HMP) paradigm by estimating 460 nm absorption at central and peripheral retinal locations. For the HMP measurements, two lights (B: 460 nm and R: 660 nm) were presented in a test field and were modulated in counterphase at medium or high frequencies. The contrasts of the two lights were varied in tandem to determine flicker detection thresholds. Detection thresholds were measured for different R:B modulation ratios. The modulation ratio with minimal sensitivity (maximal threshold) is the point of equiluminance. Measurements were performed in 25 normal subjects (11 male, 14 female; age: 30±11 years, mean ± sd) using an eight channel LED stimulator with Maxwellian view optics. The results were compared with those from two published techniques – one based on heterochromatic flicker photometry (Macular Densitometer) and the other on fundus reflectometry (MPR). We were able to estimate MPOD with HMP using a modified theoretical model that was fitted to the HMP data. The resultant MPODHMP values correlated significantly with the MPODMPR values and with the MPODHFP values obtained at 0.25° and 0.5° retinal eccentricity. HMP is a flicker-based method with measurements taken at a constant mean chromaticity and luminance. The data can be well fit by a model that allows all data points to contribute to the photometric equality estimate. Therefore, we think that HMP may be a useful method for MPOD measurements, in basic and clinical vision experiments.
11 May 2020 in Translational Vision Science & Technology
Purpose: Inherited retinal diseases affect the L-, M-, S-cones and rods in distinct ways, which calls for new methods that enable quantification of photoreceptor-specific functions. We tested the feasibility of using the silent substitution paradigm to estimate photoreceptor-driven temporal contrast sensitivity (tCS) functions in patients with retinitis pigmentosa. Methods: The silent substitution paradigm is based on substitution of lights of different spectral composition; this offers considerable advantage over other stimulation techniques. We used a four-primary LED stimulator to create perifoveal annular stimuli (2° inner, 12° outer diameters) and used a triple silent substitution to probe photoreceptor-selective tCS. Measurements were performed in a heterogeneous cohort of 15 patients with retinitis pigmentosa and related to those in a control group of nine color-normal healthy observers. Age differences between groups were addressed with a model of age-related normal contrast sensitivity derived from measurements in 20 healthy observers aged between 23 and 83 years. Results: The age-related loss of tCS amounted to 0.1 dB/year in healthy subjects across all photoreceptor subtypes. In patients, tCS was decreased for every photoreceptor subtype; however, S-cone- and rod-driven sensitivities were most strongly affected. Postreceptoral mechanisms were not affected. Conclusions: This feasibility study provides evidence that the silent substitution technique enables the estimation of photoreceptor-selective tCS functions and can serve as an accurate biomarker of photoreceptor-specific contrast sensitivity loss in patients with retinitis pigmentosa. Translational Relevance: We aim to develop tests of visual function for clinical trials of novel therapies for inherited retinal diseases from methods that can currently be used only in vision research labs.