Robert Dickinson

Dr. Robert Dickinson

Dept of Bioengineering, Imperial College, London
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2012 in BMC Bioinformatics
Verified
Journal Article
Open access
PDF file
Xian YangXian Yang
Xian Yang
RHRui Han
Rui Han
YGYike Guo
Yike Guo
JBJeremy Bradley
Jeremy Bradley
BCBenita Cox
Benita Cox
RKRichard Kitney
Richard Kitney
Background: Hospitals nowadays have to serve numerous patients with limited medical staff and equipment while maintaining healthcare quality. Clinical pathway informatics is regarded as an efficient way to solve a series of hospital challenges. To date, conventional research lacks a mathematical model to describe clinical pathways. Existing vague descriptions cannot fully capture the complexities accurately in clinical pathways and hinders the effective management and further optimization of clinical pathways. Method: Given this motivation, this paper presents a clinical pathway management platform, the Imperial Clinical Pathway Analyzer (ICPA). By extending the stochastic model performance evaluation process algebra (PEPA), ICPA introduces a clinical-pathway-specific model: clinical pathway PEPA (CPP). ICPA can simulate stochastic behaviours of a clinical pathway by extracting information from public clinical databases and other related documents using CPP. Thus, the performance of this clinical pathway, including its throughput, resource utilisation and passage time can be quantitatively analysed. Results: A typical clinical pathway on stroke extracted from a UK hospital is used to illustrate the effectiveness of ICPA. Three application scenarios are tested using ICPA: 1) redundant resources are identified and removed, thus the number of patients being served is maintained with less cost; 2) the patient passage time is estimated, providing the likelihood that patients can leave hospital within a specific period; 3) the maximum number of input patients are found, helping hospitals to decide whether they can serve more patients with the existing resource allocation. Conclusions: ICPA is an effective platform for clinical pathway management: 1) ICPA can describe a variety of components (state, activity, resource and constraints) in a clinical pathway, thus facilitating the proper understanding of complexities involved in it; 2) ICPA supports the performance analysis of clinical pathway, thereby assisting hospitals to effectively manage time and resources in clinical pathway.

16 February 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
ZJZheng Jiang
Zheng Jiang
Robert DickinsonRobert Dickinson
Robert Dickinson
THTimothy L. Hall
Timothy L. Hall
JCJames J. Choi
James J. Choi
Therapeutic ultrasound technologies using microbubbles require a feedback control system to perform the treatment in a safe and effective manner. Current feedback control technologies utilize the microbubble's acoustic emissions to adjust the treatment acoustic parameters. Typical systems use two separated transducers: one for transmission and the other for reception. However, separating the transmitter and receiver leads to foci misalignment. This limitation could be resolved by arranging the transmitter and receiver in a stacked configuration. Taking advantage of an increasing number of short-pulse-based therapeutic methods, we have constructed a lead zirconate titanate-polyvinylidene fluoride (PZT-PVDF) stacked transducer design that allows the transmission and reception of short-pulse ultrasound from the same location. Our design had a piston transmitter composed of a PZT disk (1 MHz, 12.7 mm in diameter), a backing layer, and two matching layers. A layer of PVDF ( 28 μm in thickness, 12.7 mm in diameter) was placed at the front surface of the transmitter for reception. Transmission and reception from the same location were demonstrated in pulse-echo experiments where PZT transmitted a pulse and both PZT and PVDF received the echo. The echo signal received by the PVDF was 0.43 μs shorter than the signal received by the PZT. Reception of broadband acoustic emissions using the PVDF was also demonstrated in experiments where microbubbles were exposed to ultrasound pulses. Thus, we have shown that our PZT-PVDF stack design has unique transmission and reception features that could be incorporated into a multielement array design that improves focal superimposing, transmission efficiency, and reception sensitivity.

5 January 2007 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
MIMario G. Iobbi
Mario G. Iobbi
ASAnita K. Simonds
Anita K. Simonds
Robert DickinsonRobert Dickinson
Robert Dickinson

29 January 2021 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
MZMuhammad Zubair
Muhammad Zubair
Robert DickinsonRobert Dickinson
Robert Dickinson
Experimental validation of a synthetic aperture imaging technique using a therapeutic random phased array is described, demonstrating the dual nature of imaging and therapy of such an array. The transducer is capable of generating both continuous wave high intensity beams for ablating the tumor and low intensity ultrasound pulses to image the target area. Pulse-echo data is collected from the elements of the phased array to obtain B-mode images of the targets. Since therapeutic arrays are optimized for therapy only with concave apertures having low f-number and large directive elements often coarsely sampled, imaging can not be performed using conventional beamforming. We show that synthetic aperture imaging is capable of processing the acquired RF data to obtain images of the field of interest. Simulations were performed to compare different synthetic aperture imaging techniques to identify the best algorithm in terms of spatial resolution. Experimental validation was performed using a 1 MHz, 256-elements, spherical random phased array with 130 mm radius of curvature. The array was integrated with a research ultrasound scanner via custom connectors to acquire raw RF data for variety of targets. Imaging was implemented using synthetic aperture beamforming to produce images of a rib phantom and ex vivo ribs. The array was shown to resolve spherical targets within ±15 mm of either side of the axis in the focal plane and obtain 3D images of the rib phantom up to ±40 mm of either side of the central axis and at a depth of 3–9 cm from the array surface. The lateral and axial full width half maximum was 1.15 mm and 2.75 mm, respectively. This study was undertaken to emphasize that both therapy and image guidance with a therapeutic random phased array is possible and such a system has the potential to address some major limitations in the existing high intensity focused ultrasound (HIFU) systems. The 3D images obtained with a therapeutic array can be used to identify and locate strong scattering objects aiding to image guidance and treatment planning of the HIFU procedure.

14 October 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
ZJZheng Jiang
Zheng Jiang
KSKrit Sujarittam
Krit Sujarittam
BYBetul Ilbilgi Yildiz
Betul Ilbilgi Yildiz
Robert DickinsonRobert Dickinson
Robert Dickinson
JCJames J. Choi
James J. Choi
Therapeutic ultrasound and microbubble technologies seek to drive systemically administered microbubbles into oscillations that safely manipulate tissue or release drugs. Such procedures often detect the unique acoustic emissions from microbubbles with the intention of using this feedback to control the microbubble activity. However, most sensor systems reported introduce distortions to the acoustic signal. Acoustic shockwaves, a key emission from microbubbles, are largely absent in reported recording, possibly due to the sensors being too large or too narrowband, or having strong phase distortions. Here, we built a sensor array that countered such limitations with small, broadband sensors and a low phase distorting material. We built 8 needle hydrophones with polyvinylidene fluoride (PVDF, diameter: 2 mm) then fit them into a 3D-printed scaffold in a two-layered, staggered arrangement. Using this array, we monitored microbubbles exposed to therapeutically-relevant ultrasound pulses (center frequency: 0.5 MHz, peak-rarefactional pressure: 130-597 kPa, pulse length: 4 cycles). Our tests revealed that the hydrophones were broadband with the best having a sensitivity of -224.8± 3.2 dB re 1 V/μPa from 1 to 15 MHz. The array was able to capture shockwaves generated by microbubbles. The signal-to-noise (SNR) ratio of the array was approximately 2 times higher than individual hydrophones. Also, the array could localize microbubbles (-3dB lateral resolution: 2.37 mm) and determine the cavitation threshold (between 161 kPa and 254 kPa). Thus, the array accurately monitored and localized microbubble activities, and may be an important technological step towards better feedback control methods and safer and more effective treatments.

12 July 2013 in The Visual Computer
Verified
Journal Article
Closed access
PDF file
VLVincent Luboz
Vincent Luboz
JKJim Kyaw-Tun
Jim Kyaw-Tun
SSSayan Sen
Sayan Sen
RKRoger Kneebone
Roger Kneebone
Robert DickinsonRobert Dickinson
Robert Dickinson
FBFernando Bello
Fernando Bello