In recent years, non-linear loads on the distribution side are increasing rapidly. Notably, the electric arc furnace (EAF) is the most used non-linear load due to its diverse applications for industrial needs. However, EAF has some disadvantages like uneven distribution of heat inside the furnace, release of unwanted gases, increased level of harmonics, and Flickers in voltages. Specifically, power quality concerns are more and need comprehensive solutions. In this work, a matrix converter (MC) along with static VAR compensator (SVC) is proposed, and the hybrid exponential-hyperbolic furnace model is adapted in MATLAB platform. Simulations are carried out for different cases and the observed results are compared with existing methodologies. It was perceived that the power quality parameters such as peak current and voltages, total harmonic distortions (THDs), voltage flickers, and power factors are enhanced compared with existing methodologies. Precisely, the THD of current and voltage attains a prime rate of about 2.85% and 29.54%, respectively. Moreover, the proposed model’s voltage flicker and power factor offer a grander scale of about 1.26% and 0.9975, respectively. The enhanced scheme provides more significant advantages to the large-scale steel manufacturing plant with EAF.
The water quality parameters analysis was carried out in the Gummidipoondi Lake located in Thiruvallur district of Tamil Nadu, India. As the Lake was only source for the farmers for irrigation in their place, contamination of the Lake is the major threat. The contamination factors for that Lake are mainly due to the manufacturing industries which are present around the water body. Farming is the only occupation of the surroundings. In order to protect the water body which is serving as a backbone for that community, a complete analysis is carried out to monitor the water quality parameters. Currently, offline investigation is carried out by the water supply and drainage board. The junior water analyst will directly inspect the water bodies, collect samples and do testing either in laboratories or in field using the kits available. The sets of data will be available after completing a number of tests and displayed in the website by manual entry. In order to carry a real-time analysis and the direct providing of data in the website, an online investigation method is implemented and tested in the Gummidipoondi Lake. The main parameters of this lake water are the temperature, pH and the turbidity. This concept uses real-time processors with sensors, connecting protocols and the display of results in the web interface. The results produced by the method are used to provide the contamination happened in the lake and alert the public works department to take necessary action to avoid the contamination. The outputs are displayed in the website to give current updates about the condition of the Gummidipoondi Lake.
1 January 2021 in IOP Conference Series: Materials Science and Engineering
The usage of drones or unmanned aerial vehicle in military applications is increasing. The input or the control of drones is becoming a challenging task for the developers. One of the input recognition methods is the gesture recognition. Pilot’s head movement using a gyroscope is used to control the angle of an on- board FPV (First Person Video) Camera. MPU 6050 Sensor collects the displaced values from three axis and sent it as an input for the processor which reads the possible values. The values are then compared and processed and given to the output. The output is controlled by servomotor which actuates mechanical moves based on MPU sensor. This whole setup can be connected through wireless RC (Radio Controller) transmitter and receiver. This motion controlled mechanical arms can be used for various applications like FPV (First Person View) in drone enabled surveillances, Military, Search and Rescue etc.
Thiruvallur District in Tamil Nadu is one such district, with groundwater levels reaching depths of 50m to 60m below the surface. Growing populations, variations in land use patterns, reduction in rainfall depth, and other factors all contributed to an increase in water demand and a decrease in water potential. This affects the quality of groundwater as well. In this study, the variation of both Groundwater potential and Groundwater Quality is analyzed. The collected data has undergone thorough processing to ensure its accuracy and relevance for the area to be studied. (Thiruvallur District). The base map for the place to be analyzed and the well-map are created in the QGIS software with the data. The processed data is imported into the QGIS to create a database. With the database, the spatial variation between the stations is mapped. The temporal variation of the stations is carried out. The spatial map is done for the groundwater level and Groundwater quality parameters like pH, TDS, Cl, etc. The temporal variation is shown in the graph for the GW level and GW quality parameters with respect to the well-points.
Groundwater quality is a critical indicator of water usability for drinking and irrigation. Tiruvallur district, spanning approximately 3,394 square kilometres, is one of the largest districts in Tamil Nadu, India. Due to rapid population growth, urbanization, and industrial activities, overexploitation of groundwater has significantly deteriorated its quality, posing challenges for sustainable living. This study evaluates the groundwater quality in Tiruvallur, where groundwater serves as the primary source of drinking water due to inadequate surface water availability. The study addresses declining groundwater quality in Tiruvallur District using a novel integration of Water Quality Index and GIS-based spatial mapping. Groundwater samples were collected from 10 dug wells across the district. Key physicochemical parameters, including pH, total hardness (TH), total dissolved solids (TDS), and electrical conductivity, were analyzed to calculate the Water Quality Index (WQI). The suitability of groundwater for drinking and irrigation was assessed against the standards set by the Bureau of Indian Standards (BIS) and the World Health Organization (WHO). Geographic Information System (GIS) techniques, particularly QGIS, were employed to create spatial distribution maps of water quality parameters. Box plot analysis highlighted a strong correlation between total dissolved solids and electrical conductivity, further emphasizing the need for sustainable groundwater management. This study provides a comprehensive spatial representation of groundwater quality, aiding stakeholders in implementing effective water resource management strategies.