Adriano Di Giovanni

Dr. Adriano Di Giovanni

New York University Abu Dhabi
+1
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2018 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
EAE. Aprile
E. Aprile
JAJ. Aalbers
J. Aalbers
FAF. Agostini
F. Agostini
MAM. Alfonsi
M. Alfonsi
LAL. Althueser
L. Althueser
X7XENON Collaboration 7
XENON Collaboration 7
We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01)  ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6]  keVee ([4.9,40.9] keVnr), exhibits an ultralow electron recoil background rate of [82−3+5(syst)±3(stat)]  events/(ton yr keVee). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6  GeV/c2, with a minimum of 4.1×10−47  cm2 at 30  GeV/c2 and a 90% confidence level.

30 October 2017 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
EAE. Aprile
E. Aprile
JAJ. Aalbers
J. Aalbers
FAF. Agostini
F. Agostini
MAM. Alfonsi
M. Alfonsi
FAF. D. Amaro
F. D. Amaro
XCXENON Collaboration
XENON Collaboration
We report the first dark matter search results from XENON1T, a ∼2000−kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042±12)−kg fiducial mass and in the [5,40]  keVnr energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (1.93±0.25)×10−4  events/(kg×day×keVee), the lowest ever achieved in such a dark matter detector. A profile likelihood analysis shows that the data are consistent with the background-only hypothesis. We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10  GeV/c2, with a minimum of 7.7×10−47  cm2 for 35−GeV/c2 WIMPs at 90% C.L.

1 November 2016 in Journal of Cosmology and Astroparticle Physics
Verified
Journal Article
Open access
PDF file
JAJ. Aalbers
J. Aalbers
FAF. Agostini
F. Agostini
MAM. Alfonsi
M. Alfonsi
FAF.D. Amaro
F.D. Amaro
CAC. Amsler
C. Amsler
KZK. Zuber
K. Zuber

17 December 2019 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
EAE. Aprile
E. Aprile
JAJ. Aalbers
J. Aalbers
FAF. Agostini
F. Agostini
MAM. Alfonsi
M. Alfonsi
LAL. Althueser
L. Althueser
XCXENON Collaboration
XENON Collaboration
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of (22±3) tonne day. Above ∼0.4  keVee, we observe <1  event/(tonne day keVee), which is more than 1000 times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses mχ within 3–6  GeV/c2, DM-electron scattering for mχ>30  MeV/c2, and absorption of dark photons and axionlike particles for mχ within 0.186–1  keV/c2.

1 April 2016 in Journal of Cosmology and Astroparticle Physics
Verified
Journal Article
Closed access
PDF file
EAE. Aprile
E. Aprile
JAJ. Aalbers
J. Aalbers
FAF. Agostini
F. Agostini
MAM. Alfonsi
M. Alfonsi
FAF. D. Amaro
F. D. Amaro
YZY. Zhang
Y. Zhang
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds.The total electronic recoil background in 1 tonne fiducial volume and (1, 12) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is (1.80 ± 0.15) · 10−4(kg·day·keV)−1, mainly due to the decay of222Rn daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region (4, 50) keV, is composed of (0.6 ± 0.1) (t·y)−1from radiogenic neutrons, (1.8 ± 0.3) · 10−2(t·y)−1from coherent scattering of neutrinos, and less than 0.01 (t·y)−1from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency ℒeff, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a 2 y measurement in 1 t fiducial volume, the sensitivity reaches a minimum cross section of 1.6 · 10−47cm2at mχ = 50 GeV/c2.

13 December 2019 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
EAE. Aprile
E. Aprile
JAJ. Aalbers
J. Aalbers
FAF. Agostini
F. Agostini
MAM. Alfonsi
M. Alfonsi
LAL. Althueser
L. Althueser
XCXENON Collaboration
XENON Collaboration
Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above ∼5  GeV/c2, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a bremsstrahlung photon. In this Letter, we report on a probe of low-mass dark matter with masses down to about 85  MeV/c2 by looking for electronic recoils induced by the Migdal effect and bremsstrahlung using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.