Yi-Hui Lin

Prof. Yi-Hui Lin

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Analytical Sciences
Verified
Journal Article
Closed access
PDF file
SWShihchun Wei
Shihchun Wei
YLYijia Li
Yijia Li
HLHsinhua Liang
Hsinhua Liang
YYYaote Yen
Yaote Yen
YLYi-Hui Lin
Yi-Hui Lin
Huan-Tsung ChangHuan-Tsung Chang
Huan-Tsung Chang
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.

13 September 2024 in Journal of Food and Drug Analysis
Verified
Journal Article
Open access
PDF file
CCChun-Hsien Chen
Chun-Hsien Chen
HLHsin-Hua Liang
Hsin-Hua Liang
CWChun-Chi Wang
Chun-Chi Wang
YYYi-Ting Yang
Yi-Ting Yang
YLYi-Hui Lin
Yi-Hui Lin
YCYen-Ling Chen
Yen-Ling Chen
Alzheimer's disease (AD) is a chronic and progressive neurodegenerative disorder that affects millions of individuals worldwide. Researchers have conducted numerous studies to find accurate biomarkers for early AD diagnosis and develop more effective treatments. The main pathological hallmarks of AD are amyloid beta and Tau proteins. Other biomarkers, such as DNA, RNA, and proteins, can also be helpful in early AD diagnosis. To diagnose and treat AD promptly, it is essential to accurately measure the concentration of biomarkers in the cerebrospinal fluid or blood. However, due to the low concentrations of these biomarkers in the body, highly sensitive analytical techniques are required. To date, sensors have become increasingly important due to their high sensitivity, swift detection, and adaptable manipulation features. These qualities make them an excellent substitute for conventional instruments. Nanomaterials are commonly employed in sensors to amplify signals and improve sensitivity. This review paper summarized the integration of nanomaterials in optical sensor systems, including colorimetric, fluorescent, and surface-enhanced Raman scattering sensors for AD biomarkers detection.

10 July 2015 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
YLYi-Hui Lin
Yi-Hui Lin
HHHsin-Chieh Huang
Hsin-Chieh Huang
WHWan-Ling Hsu
Wan-Ling Hsu

25 November 2023 in Microchemical Journal
Verified
Journal Article
Closed access
HLHsin-Hua Liang
Hsin-Hua Liang
YLYu-Chao Lin
Yu-Chao Lin
Chin-Chuan HungChin-Chuan Hung
Chin-Chuan Hung
YHYu-Chi Hou
Yu-Chi Hou
YLYi-Hui Lin
Yi-Hui Lin

1 December 2015 in Journal of Chromatography A
Verified
Journal Article
Closed access
HCHui-Ling Cheng
Hui-Ling Cheng
YTYi-Hsuan Tsai
Yi-Hsuan Tsai
WHWan-Ling Hsu
Wan-Ling Hsu
YLYi-Hui Lin
Yi-Hui Lin

Verified
Journal Article
Open access
PDF file
HLHsin-Hua Liang
Hsin-Hua Liang
YLYu-Chao Lin
Yu-Chao Lin
Chin-Chuan HungChin-Chuan Hung
Chin-Chuan Hung
YHYu-Chi Hou
Yu-Chi Hou
YLYi-Hui Lin
Yi-Hui Lin
In this study, we established a novel capillary electrophoresis method for monitoring the concentration of doripenem in human plasma. As a time-dependent antibiotic, doripenem maximizes its antibacterial effects and minimizes the potential for antibiotic resistance through careful therapeutic drug monitoring. Two online preconcentration techniques, field-enhanced sample stacking (FESS) and sweeping, were coupled to enhance the detection sensitivity. Briefly, an uncoated fused silica capillary (40 cm × 50 μm i.d) was rinsed with a high conductivity buffer (HCB) composed of 150 mM phosphate buffer (NaH2PO4, pH 2.5) and 20% methanol. A large sample plug prepared in a low-conductivity phosphate buffer (50 mM NaH2PO4, pH 2.5) was then hydrodynamically injected (5 psi, 80 s) into the capillary. Under an applied voltage of −30 kV, the analyte was accumulated at the FESS boundary and swept by the negatively charged micelles toward the UV detector. Plasma samples were pretreated by solid-phase extraction (SPE) to eliminate endogenous interferences. The validation results demonstrated a high coefficient of determination (r2 > 0.9995) for the regression curve with impressive precision and accuracy: relative standard deviation (RSD) <5.86% and relative error <4.63%. The limit of detection (LOD, S/N = 3) for doripenem was determined to be 0.4 μg/mL. Compared to the conventional micellar electrokinetic chromatography method, our developed method achieved a sensitivity enhancement of up to 488-fold for doripenem. Furthermore, the newly developed method successfully quantified doripenem concentrations in plasma samples obtained from patients accepting doripenem regimens, proving its application potential in the clinical realm.