M. Patricia Fabian

Dr. M. Patricia Fabian

Department of Environmental Health Boston University 715 Albany St., T4W, Boston, MA 02118, USA
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2013 in PLOS Pathogens
Verified
Journal Article
Open access
PDF file
DMDonald K. Milton
Donald K. Milton
MFM. Patricia Fabian
M. Patricia Fabian
BCBenjamin Cowling
Benjamin Cowling
MGMichael L. Grantham
Michael L. Grantham
JMJames J. McDevitt
James J. McDevitt
The CDC recommends that healthcare settings provide influenza patients with facemasks as a means of reducing transmission to staff and other patients, and a recent report suggested that surgical masks can capture influenza virus in large droplet spray. However, there is minimal data on influenza virus aerosol shedding, the infectiousness of exhaled aerosols, and none on the impact of facemasks on viral aerosol shedding from patients with seasonal influenza. We collected samples of exhaled particles (one with and one without a facemask) in two size fractions (“coarse”>5 µm, “fine”≤5 µm) from 37 volunteers within 5 days of seasonal influenza onset, measured viral copy number using quantitative RT-PCR, and tested the fine-particle fraction for culturable virus. Fine particles contained 8.8 (95% CI 4.1 to 19) fold more viral copies than did coarse particles. Surgical masks reduced viral copy numbers in the fine fraction by 2.8 fold (95% CI 1.5 to 5.2) and in the coarse fraction by 25 fold (95% CI 3.5 to 180). Overall, masks produced a 3.4 fold (95% CI 1.8 to 6.3) reduction in viral aerosol shedding. Correlations between nasopharyngeal swab and the aerosol fraction copy numbers were weak (r = 0.17, coarse; r = 0.29, fine fraction). Copy numbers in exhaled breath declined rapidly with day after onset of illness. Two subjects with the highest copy numbers gave culture positive fine particle samples. Surgical masks worn by patients reduce aerosols shedding of virus. The abundance of viral copies in fine particle aerosols and evidence for their infectiousness suggests an important role in seasonal influenza transmission. Monitoring exhaled virus aerosols will be important for validation of experimental transmission studies in humans. The relative importance of direct and indirect contact, large droplet spray, and aerosols as modes of influenza transmission is not known but is important in devising effective interventions. Surgical facemasks worn by patients are recommended by the CDC as a means of reducing the spread of influenza in healthcare facilities. We sought to determine the total number of viral RNA copies present in exhaled breath and cough aerosols, whether the RNA copies in fine particle aerosols represent infectious virus, and whether surgical facemasks reduce the amount of virus shed into aerosols by people infected with seasonal influenza viruses. We found that total viral copies detected by molecular methods were 8.8 times more numerous in fine (≤5 µm) than in coarse (>5 µm) aerosol particles and that the fine particles from cases with the highest total number of viral RNA copies contained infectious virus. Surgical masks reduced the overall number of RNA copies by 3.4 fold. These results suggest an important role for aerosols in transmission of influenza virus and that surgical facemasks worn by infected persons are potentially an effective means of limiting the spread of influenza.

16 July 2008 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MFM. Patricia Fabian
M. Patricia Fabian
JMJames J. McDevitt
James J. McDevitt
WDWesley H. DeHaan
Wesley H. DeHaan
RFRita O. P. Fung
Rita O. P. Fung
BCBenjamin Cowling
Benjamin Cowling
DMDonald K. Milton
Donald K. Milton
Recent studies suggest that humans exhale fine particles during tidal breathing but little is known of their composition, particularly during infection. We conducted a study of influenza infected patients to characterize influenza virus and particle concentrations in their exhaled breath. Patients presenting with influenza-like-illness, confirmed influenza A or B virus by rapid test, and onset within 3 days were recruited at three clinics in Hong Kong, China. We collected exhaled breath from each subject onto Teflon filters and measured exhaled particle concentrations using an optical particle counter. Filters were analyzed for influenza A and B viruses by quantitative polymerase chain reaction (qPCR). Twelve out of thirteen rapid test positive patients provided exhaled breath filter samples (7 subjects infected with influenza B virus and 5 subjects infected with influenza A virus). We detected influenza virus RNA in the exhaled breath of 4 (33%) subjects–three (60%) of the five patients infected with influenza A virus and one (14%) of the seven infected with influenza B virus. Exhaled influenza virus RNA generation rates ranged from <3.2 to 20 influenza virus RNA particles per minute. Over 87% of particles exhaled were under 1 µm in diameter. These findings regarding influenza virus RNA suggest that influenza virus may be contained in fine particles generated during tidal breathing, and add to the body of literature suggesting that fine particle aerosols may play a role in influenza transmission.

1 December 2011 in American Journal of Public Health
Verified
Journal Article
Closed access
GAGary Adamkiewicz
Gary Adamkiewicz
AZAmi R. Zota
Ami R. Zota
MFM. Patricia Fabian
M. Patricia Fabian
TCTeresa Chahine
Teresa Chahine
RJRhona Julien
Rhona Julien
JLJonathan Levy
Jonathan Levy
Objectives. The indoor environment has not been fully incorporated into the environmental justice dialogue. To inform strategies to reduce disparities, we developed a framework to identify the individual and place-based drivers of indoor environment quality. Methods. We reviewed empirical evidence of socioeconomic disparities in indoor exposures and key determinants of these exposures for air pollutants, lead, allergens, and semivolatile organic compounds. We also used an indoor air quality model applied to multifamily housing to illustrate how nitrogen dioxide (NO2) and fine particulate matter (PM2.5) vary as a function of factors known to be influenced by socioeconomic status. Results. Indoor concentrations of multiple pollutants are elevated in low-socioeconomic status households. Differences in these exposures are driven by the combined influences of indoor sources, outdoor sources, physical structures, and residential activity patterns. Simulation models confirmed indoor sources’ importance in determining indoor NO2 and PM2.5 exposures and showed the influence of household-specific determinants. Conclusions. Both theoretical models and empirical evidence emphasized that disparities in indoor environmental exposure can be significant. Understanding key determinants of multiple indoor exposures can aid in developing policies to reduce these disparities.

1 March 2011 in Journal of Aerosol Medicine and Pulmonary Drug Delivery
Verified
Journal Article
Closed access
MFM. Patricia Fabian
M. Patricia Fabian
JBJoseph Brain
Joseph Brain
EHE. Andres Houseman
E. Andres Houseman
JGJames Gern
James Gern
DMDonald K. Milton
Donald K. Milton
Background: Exhaled breath studies suggest that humans exhale fine particles during tidal breathing, but little is known of their physical origin in the respiratory system during health or disease. Methods: Particles generated by 3 healthy and 16 human rhinovirus (HRV)-infected subjects were counted using an optical particle counter with nominal diameter-size bins ranging between 0.3 and 10 μm. Data were collected from HRV-infected subjects during tidal breathing. In addition, data from healthy subjects were collected during coughs, swallows, tidal breathing, and breathing to total lung capacity (TLC) and residual volume (RV). Using general additive models, we graphed exhaled particle concentration versus airflow during exhalation. Exhaled particles were collected from expired air on gelatin filters and analyzed for HRV via quantitative PCR. Results: HRV-infected subjects exhaled from 0.1 to 7200 particles per liter of exhaled air during tidal breathing (geometric mean = 32 part/L). A small fraction (24%) of subjects exhaled most (81%) of the particles measured and 82% of particles detected were 0.300–0.499 μm. Minute ventilation, maximum airflow during exhalation, and forced expiratory volume 1 second (FEV 1 % predicted) were positively correlated with particle production. No human rhinovirus was detected in exhaled breath samples. Three healthy subjects exhaled less than 100 particles per liter of exhaled air during tidal breathing and increased particle concentrations more with exhalation to RV than with coughing, swallowing, or rapid exhalation. Conclusions: Submicron particles were detected in the exhaled breath of healthy and HRV-infected subjects. Particle concentrations were correlated with airflow during the first half of exhalation, and peaked at the end of exhalation, indicating both lower and upper airways as particle sources. The effect of breathing maneuver suggested a major contribution from lower airways, probably the result of opening collapsed small airways and alveoli.

14 September 2009 in Indoor Air
Verified
Journal Article
Closed access
PDF file
MFM. Patricia Fabian
M. Patricia Fabian
JMJ. J. McDevitt
J. J. McDevitt
EHE. A. Houseman
E. A. Houseman
DMD. K. Milton
D. K. Milton
Click on the article title to read more.

1 January 2003 in Atmospheric Environment
Verified
Journal Article
Closed access
PXPeng Xu
Peng Xu
JPJordan Peccia
Jordan Peccia
MFM. Patricia Fabian
M. Patricia Fabian
JMJohn W. Martyny
John W. Martyny
KFKevin P. Fennelly
Kevin P. Fennelly
SMShelly Miller
Shelly Miller