Alfredo De Leo

Dr. Alfredo De Leo

Information Engineering Department, Università Politecnica delle Marche, via Brecce Bianche 12, 60131 Ancona, Italy
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Emanuele CardilloEmanuele Cardillo
Emanuele Cardillo
VMValentina Di Mattia
Valentina Di Mattia
GMGiovanni Manfredi
Giovanni Manfredi
PRPaola Russo
Paola Russo
Alfredo De LeoAlfredo De Leo
Alfredo De Leo
GCGraziano Cerri
Graziano Cerri
The feasibility of an electromagnetic sensor to assist the autonomous walking of visually impaired and blind users is demonstrated in this paper. It is known that the people affected by visual diseases usually walk assisted by some supports, among which the white cane is the most common. Our idea consists in applying a microwave radar on the traditional white cane making aware the user about the presence of an obstacle in a wider and safer range. Compared to the already existing electronic travel aids devices, the proposed system exhibits better performance, noise tolerance, and reduced dimensions. In the following, the latest developments of this research activity are presented, with special concern for the miniaturization of circuit board and antennas. A laboratory prototype has been designed and realized and the first test results of obstacle detection are hereby shown to demonstrate the effectiveness of the system.

12 July 2017 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
Alfredo De LeoAlfredo De Leo
Alfredo De Leo
GCGraziano Cerri
Graziano Cerri
PRPaola Russo
Paola Russo
Valter Mariani PrimianiValter Mariani Primiani
Valter Mariani Primiani
A low-frequency experimental characterization of a multiple monopole-source-stirred reverberation chamber is presented and the results are compared to the prediction of an analytical model. At first quality factor was determined, then the statistic of the received power and Rician K-factor as well as the electric field uniformity and anisotropy. All the experimental results are in good agreement with the prediction of the analytical model, demonstrating its accuracy in designing a source-stirring chamber.

16 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MPMarco Pieralisi
Marco Pieralisi
VMValentina Di Mattia
Valentina Di Mattia
VPValerio Petrini
Valerio Petrini
Alfredo De LeoAlfredo De Leo
Alfredo De Leo
GMGiovanni Manfredi
Giovanni Manfredi
GCGraziano Cerri
Graziano Cerri
Currently, the availability of technology developed to increase the autonomy of visually impaired athletes during sports is limited. The research proposed in this paper (Part I and Part II) focuses on the realization of an electromagnetic system that can guide a blind runner along a race track without the need for a sighted guide. In general, the system is composed of a transmitting unit (widely described in Part I) and a receiving unit, whose components and main features are described in this paper. Special attention is paid to the definition of an electromagnetic model able to faithfully represent the physical mechanisms of interaction between the two units, as well as between the receiving magnetic sensor and the body of the user wearing the device. This theoretical approach allows for an estimation of the signals to be detected, and guides the design of a suitable signal processing board. This technology has been realized, patented, and tested with a blind volunteer with successful results and this paper presents interesting suggestions for further improvements.

8 July 2015 in Sensors
Verified
Journal Article
Open access
PDF file
MPMarco Pieralisi
Marco Pieralisi
VPValerio Petrini
Valerio Petrini
VMValentina Di Mattia
Valentina Di Mattia
GMGiovanni Manfredi
Giovanni Manfredi
Alfredo De LeoAlfredo De Leo
Alfredo De Leo
GCGraziano Cerri
Graziano Cerri
Nowadays the technologies aimed at improving the quality of life of people affected by visual diseases are quite common; e.g., devices to support walking or reading. Surprisingly, there is a lack of innovative technologies aimed at helping visually impaired athletes during physical activities. An example is represented by blind runners who need to be physically linked to a sighted guide by means of non-stretchable tethers during races; with consequent limitations in terms of performance and independence. This paper wants to investigate the possibility of realizing a system able to guide blind runners along a complex path, paving the way for the realization of an innovative device designed to improve their independence during training or competitions. The system consists of: (1) a mobile unit, which is placed before the runner and generates two “electromagnetic walls” delimiting the way; (2) a receiving unit (worn by the athlete) that provides vibro-tactile warnings every time the user is going outside the safe area so as to encourage him to move toward the central position. The feasibility and the utility of the system proposed are demonstrated by means of tests carried out thanks to the collaboration of a blind volunteer.

14 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MPMarco Pieralisi
Marco Pieralisi
VMValentina Di Mattia
Valentina Di Mattia
VPValerio Petrini
Valerio Petrini
Alfredo De LeoAlfredo De Leo
Alfredo De Leo
GMGiovanni Manfredi
Giovanni Manfredi
GCGraziano Cerri
Graziano Cerri
Sport is one of the best ways to promote the social integration of people affected by physical disability, because it helps them to increase their self-esteem by facing difficulties and overcoming their disabilities. Nowadays, a large number of sports can be easily played by visually impaired and blind athletes without any special supports, but, there are some disciplines that require the presence of a sighted guide. In this work, the attention will be focused on marathons, during which athletes with visual disorders have to be linked to the sighted guide by means of a non-stretchable elbow tether, with an evident reduction of their performance and autonomy. In this context, this paper presents a fixed electromagnetic infrastructure to equip a standard running racetrack in order to help a blind athlete to safely run without the presence of a sighted guide. The athlete runs inside an invisible hallway, just wearing a light and a comfortable sensor unit. The patented system has been homemade, designed, realized and finally tested by a blind Paralympic marathon champion with encouraging results and interesting suggestions for technical improvements. In this paper (Part I), the transmitting unit, whose main task is to generate the two magnetic fields that delimit the safe hallway, is presented and discussed.

22 April 2013 in International Journal of Antennas and Propagation
Verified
Journal Article
Open access
PDF file
Lorenzo ScaliseLorenzo Scalise
Lorenzo Scalise
Valter Mariani PrimianiValter Mariani Primiani
Valter Mariani Primiani
Paola RussoPaola Russo
Paola Russo
Alfredo De LeoAlfredo De Leo
Alfredo De Leo
DSDesar Shahu
Desar Shahu
GCGraziano Cerri
Graziano Cerri
An electromagnetic sensing system for the measurement of the respiratory activity is presented. The aims are to demonstrate the feasibility of the proposed approach and in particular to evaluate the effect on the measured signal of the distance between the subject and the sensing apparatus. Moreover, an electromagnetic model of the system, including the monitored subject, is proposed as a tool to solve the problem of selecting working parameters for system design. The sensing system is based on the measurement of the phase variation of the reflection coefficient caused by the respiratory activity. The phase signal compared with the thorax displacement measured by a reference instrument shows a high correlation () for different subject postures (sitting, standing, and lying) and a reduction of the signal amplitude with the distance dB/cm is reported. The numerical simulations performed on a wide-band highlight the frequencies where the method exhibits the highest sensitivity to thorax movements. The sensitivity can be further improved by reducing the antenna beamwidth. Despite the signal amplitude reduction, the proposed system makes it possible to correctly operate at distances up to 2.5 m.