Vitor Vale Cardoso

Dr. Vitor Vale Cardoso

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSSofia Silva
Sofia Silva
VCVitor Vale Cardoso
Vitor Vale Cardoso
LDLúcia Duarte
Lúcia Duarte
RCRui Neves Carneiro
Rui Neves Carneiro
Cristina Maria Martins AlmeidaCristina Maria Martins Almeida
Cristina Maria Martins Almeida
Due to the high consumption and incorrect disposal of pharmaceutical active compounds (PhACs), they are recognized as contaminants of emerging concern. Wastewater treatment plants (WWTPs) may be inefficient in removing PhACs, therefore discharging them into surface waters. The removal efficiencies of five WWTPs located in the south of Portugal (Alentejo) were evaluated in 2020. Twenty-six PhACs were analyzed in wastewater influents, effluents, and surface waters, upstream and downstream of the WWTPs by solid-phase extraction (SPE) and ultra-performance liquid chromatography coupled with tandem mass detection (UPLC-MS/MS). The most representative PhACs in influents were acetaminophen, caffeine, naproxen, ibuprofen, and diclofenac with minimum-maximum concentrations of 49–225 µg/L, 26–46 µg/L, 5.9–13 µg/L, 5.2–22 µg/L, and 1.3–2.5 µg/L, respectively. For effluents, it was acetaminophen, caffeine, and diclofenac with minimum-maximum concentrations of 0.054–7.8 µg/L, 0.084–4.8 µg/L, and 0.28–3.3 µg/L, respectively. The highest removal efficiencies were observed for acetaminophen, sulfadiazine, cortisone, testosterone, metoprolol, and propranolol (100%). The lowest removal efficiencies were observed for carbamazepine (2.7%) and diclofenac (−13.2%). The risk quotient of sulfamethoxazole and diclofenac were higher than 1 for receiving waters, indicating they probably pose high risks to aquatic organisms.

14 February 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Rita DiasRita Dias
Rita Dias
DSDiogo Borges Sousa
Diogo Borges Sousa
Maria BernardoMaria Bernardo
Maria Bernardo
Inês MatosInês Matos
Inês Matos
IFIsabel Fonseca
Isabel Fonseca
Rita MaurícioRita Maurício
Rita Maurício
Presently, water quantity and quality problems persist both in developed and developing countries, and concerns have been raised about the presence of emerging pollutants (EPs) in water. The circular economy provides ways of achieving sustainable resource management that can be implemented in the water sector, such as the reuse of drinking water treatment sludges (WTSs). This study evaluated the potential of WTS containing a high concentration of activated carbon for the removal of two EPs: the steroid hormones 17β-estradiol (E2) and 17α-ethinylestradiol (EE2). To this end, WTSs from two Portuguese water treatment plants (WTPs) were characterised and tested for their hormone adsorbance potential. Both WTSs showed a promising adsorption potential for the two hormones studied due to their textural and chemical properties. For WTS1, the final concentration for both hormones was lower than the limit of quantification (LOQ). As for WTS2, the results for E2 removal were similar to WTS1, although for EE2, the removal efficiency was lower (around 50%). The overall results indicate that this method may lead to new ways of using this erstwhile residue as a possible adsorbent material for the removal of several EPs present in wastewaters or other matrixes, and as such contributing to the achievement of Sustainable Development Goals (SDG) targets.


11 March 2021 in Urban Water Journal
Verified
Journal Article
Open access
Catarina Silva ReisCatarina Silva Reis
Catarina Silva Reis
Cristina Maria Martins AlmeidaCristina Maria Martins Almeida
Cristina Maria Martins Almeida
JRJoão A. Rodrigues
João A. Rodrigues
SSSofia Silva
Sofia Silva
MCMaria Do Rosário Coelho
Maria Do Rosário Coelho
Maria João RosaMaria João Rosa
Maria João Rosa
The occurrence of a representative range of pharmaceutical compounds (PhCs) in urban wastewaters was studied in two Portuguese water-scarce regions (Lisbon great area, and Faro – Algarve), involving 55 sampling campaigns during 2.5 years. The results show 16 PhCs (out of the 24 analysed) were quantified in all samples, with similar concentrations in both wastewaters. To understand to what extent seasonality affects PhC occurrence, a statistical analysis was conducted, and daily maximum air temperature was identified as a key factor, with a turning point of 20°C in Lisbon and 22°C in Faro. Some PhCs showed lower concentrations in colder (wet) months due to rainwater dilution (combined sewer systems), whereas others showed higher concentrations, reflecting an increased seasonal consumption and/or slower transformation under lower temperatures and/or shorter hydraulic retention times. Seasonal studies should therefore focus on temperature rather than on calendar seasons, increasingly uncertain due to climate change.

3 April 2025 in Molecules
Verified
Journal Article
Open access
PDF file
SSSofia Silva
Sofia Silva
JRJoão A. Rodrigues
João A. Rodrigues
VCVitor Vale Cardoso
Vitor Vale Cardoso
RCRui N. Carneiro
Rui N. Carneiro
Cristina Maria Martins AlmeidaCristina Maria Martins Almeida
Cristina Maria Martins Almeida
Sample pretreatment is one of the most important steps in guaranteeing the success of a chromatographic analysis. The selected methodology must ensure simultaneously that a sample is “clean” enough for analysis and that the target analytes are not removed in the process. This can be especially difficult when working with complex matrices such as natural waters and wastewater. For pharmaceutical active compounds (PhACs) analysis by solid-phase extraction (SPE) followed by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS), and due to the high level of organic matter in wastewater, the water samples are filtered consecutively through three filters, a paper filter, a glass microfiber filter of 1 µm, and a Nylon filter of 0.45 µm. This filtration allows the sample’s passage through the SPE cartridge to be faster, and there is no cartridge clogging, allowing for greater efficiency in the adsorption process. The big question is whether the PhACs are eliminated during filtration, since they may be adsorbed to organic matter. This work aimed to determine if the best approach for quantifying PhACs in wastewater and surface waters would be to filter them prior or to perform SPE directly. Both approaches analyzed a total of 26 PhACs. Turbidity (TUR) and permanganate index (PI) were determined, and their values were high for samples with a high organic matter content. A statistical analysis was performed to determine the best approach to treat these water samples and whether any correlation existed between PhAC concentrations, PI, and TUR. The PhAC quantification shows a positive correlation with TUR and a negative correlation with PI for most of the target PhACs. However, there are not significantly different results for filtered and not-filtered wastewater samples.

18 September 2024 in Molecules
Verified
Journal Article
Open access
PDF file
RCRodrigo D.M. Cordeiro
Rodrigo D.M. Cordeiro
VCVitor Vale Cardoso
Vitor Vale Cardoso
RCRui N. Carneiro
Rui N. Carneiro
Cristina Maria Martins AlmeidaCristina Maria Martins Almeida
Cristina Maria Martins Almeida
Microplastics (MPs) contribute to the overall pollution of water sources, affecting not only aquatic ecosystems but also water for human consumption (WHC). Currently, there needs to be a global consensus on safe levels of microplastics in WHC, which will allow regulatory efforts and risk assessments to be carried out. Therefore, this study aims to characterize MP particles in WHC of the Lisbon water supply system (LWSS) and compare two approaches to quantify these particles (length and width of the particles, and the area equivalent diameter (AED) of the particles). The quantification of MP particles was made via micro-FTIR (Fourier Transform Infrared Spectroscopy) on transmission mode after water filtration on 5 µm silicon filters. Thirty-eight WHC samples from the LWSS showed MPs up to 836 MPs/L, with an average value of 196 MPs/L. The most representative polymer was polyethylene (PE, 77.2%). The other eight polymers were also quantified. The length and width of MPs ranged between 84 µm and 41 µm, respectively. The AED of MPs ranged between 24 µm and 405 µm. The MP dimensions of both approaches can differ significantly.