The use of Direct Current (DC) transmission links in power systems is increasing continuously. Thus, it is important to develop new techniques to model the inclusion of these devices in network analysis, in order to allow studies of the operation and expansion planning of large-scale electric power systems. In this context, the main objective of this paper is to present a new methodology for a simultaneous AC-DC power flow for a multi-terminal High Voltage Direct Current (HVDC) system with a generic representation of the DC network. The proposed methodology is based on a full Newton formulation for solving the AC-DC power flow problem. Equations representing the converters and steady-state control strategies are included in a power flow problem formulation, resulting in an expanded Jacobian matrix of the Newton method. Some results are presented based on HVDC test systems to confirm the effectiveness of the proposed approach.
This study presents a new methodology to determine the optimal Offshore Wind Farms connection point in a power system, with the purpose of maximising the wind power penetration, considering a Benders decomposition approach to represent the security constraints related to the ‘ ’ contingency criterion. The proposed algorithm uses a mixed‐integer non‐linear programming approach associated with a non‐linear programming, and it is evaluated in a tutorial system (IEEE 14‐Bus) and two networks from the literature: a small case (IEEE RTS‐79), and a medium and real case (Brazilian Birds System). In each case, three points geographically close to each other are selected as candidates in the onshore grid for the wind power injection. The experiments conducted clearly show that the connection decision from the proposed approach led to the maximum safe wind power penetration among the candidate options, which proves its applicability and effectiveness, even for more complex networks, and considering all single transmission line contingencies for safe operation.
11 March 2019 in Journal of Electrical and Computer Engineering
The technical, economic, and environmental constraints related to the construction of new transmission lines are complex issues related to the definition of points for connecting new offshore wind farms (OWFs) to the grid. In this context, it has become an important research topic to choose the best OWF connection point to a power system, among some geographically close to each other within a given region, aiming at ensuring maximum generation capacity of the wind farm and safe use of existing transmission network. The objective of this work is to present a methodology to determine the optimal OWF connection point in a power system, with maximum penetration of firm wind power and minimum loss, considering security constraints related to the “” contingency criterion, exchange limits between areas, and a strategy to reduce the number of constraints in the optimization problem. The algorithm is modeled using a Mixed Integer Nonlinear Programming (MINLP), and it is evaluated in a tutorial system and three well-known other networks from literature: IEEE 14-Bus, IEEE RTS-79, and Southern Brazilian System.
The economic and environmental constraints related to the construction of new transmission lines are complex issues related to the definition of the connection points of new wind farms. In this context, the safe use of the existing transmission capacity has become an important topic. This can be achieved by optimally allocating the generation capacity of each candidate wind power plant to different buses of the transmission system. The wind and load intermittent behavior and the partially-dispatchable nature of wind power plants require an analysis of all potential wind farms over an extended time-frame in a simultaneous way. This work has as main objective a detailed study of a methodology that evaluates the maximum penetration of “firm” wind energy in Electric Power Systems in order to reach the highest level of wind penetration, considering safety restrictions, limits of interchange between areas and the system operating cost.
This study aims to enhance the forecasting accuracy of photovoltaic ($\mathbf{P V}$) power generation by developing a hybrid model that integrates statistical performance analyses tailored to specific meteorological conditions. The primary objective is to construct a Combined Statistical Model by Performance (CSMP) that optimizes the predictive capabilities of individual PV generation models based on their performance across distinct irradiance and temperature ranges. Specific objectives include analyzing daily peak irradiance as the primary model selection criterion, evaluating model performance within defined irradiance intervals, incorporating air temperature to improve predictions under high irradiance conditions, and integrating these analyses using statistical metrics. The study utilizes two years of solar photovoltaic generation data from 45 kW PV systems installed at the Polytechnic Institute of Bragança (IPB), Portugal. Four statistical metrics-root mean square error (RMSE), mean bias error (MBE), mean absolute error (MAE), and percentage variation-were employed to assess model performance across various time horizons, from one day to one year. The CSMP demonstrated superior performance compared to individual models, achieving an average improvement of 7.3 % in energy prediction accuracy, highlighting the effectiveness of irradiance- and temperaturebased model optimization for reliable PV forecasting.
The reliable operation of photovoltaic (PV) systems depends on the early detection of failures such as hotspots, which are localized overheating regions typically caused by partial shading, cell mismatch, soiling, or internal defects. In these regions, affected cells operate in reverse bias and dissipate energy as heat instead of generating electricity, leading to efficiency losses, accelerated material degradation, and, in severe cases, irreversible damage or fire hazards. Conventional inspection methods, including visual evaluation and electrical testing, are time-consuming, labor-intensive, and unsuitable for large-scale solar plants. The use of Unmanned Aerial Vehicles (UAVs) equipped with thermal cameras has emerged as a promising alternative for autonomous inspection, enhancing operational efficiency and reducing human risks. In this work, we propose a hotspot detection approach based on a U-Net segmentation network applied to thermal infrared imagery of PV modules. The model was trained on a dataset that combined publicly available and laboratory-acquired images, utilizing preprocessing and augmentation strategies to enhance robustness. Experimental results demonstrate that the proposed method effectively identifies hotspot regions with precise delineation of their morphology and spatial distribution, outperforming bounding-box-based approaches such as YOLO in terms of fine-grained localization. This level of detail is crucial for predictive maintenance, as it enables the accurate measurement of hotspot size and shape. The findings highlight the potential of integrating UAV-based thermal inspection with deep learning segmentation models as a scalable and reliable solution for autonomous PV system monitoring and maintenance.