Yasuki Motozawa

Yasuki Motozawa


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
TNTomoyuki Nakanishi
Tomoyuki Nakanishi
Masahito HitosugiMasahito Hitosugi
Masahito Hitosugi
HMHaruo Murayama
Haruo Murayama
ATARISA TALEDA
ARISA TALEDA
YMYasuki Motozawa
Yasuki Motozawa
KKKatsuhiro Koyama
Katsuhiro Koyama
To establish a basis for initial diagnosis and for proposing preventive measures for the serious neck injuries occasionally experienced by judo practitioners, the biomechanical mechanisms of these injuries were analyzed. Two male judo experts repeatedly threw an anthropomorphic test device (POLAR dummy) using three throwing techniques (Seoi-nage, Osoto-gari, and Ouchi-gari). The dummy’s kinematic data were captured using a high-speed digital camera, and the load and moment of the neck were measured with load cells. The neck injury criterion (Nij) and beam criterion were also calculated. In Seoi-nage, the anterior and parietal regions of the dummy’s head contacted the tatami (judo mat). Subsequently, most of the body weight was applied, with the neck experiencing the highest compression. However, in Osoto-gari and Ouchi-gari, the occipital region of the dummy’s head contacted the tatami. Significantly higher values of both Nij (median 0.68) and beam criterion (median 0.90) corresponding to a 34.7% to 37.1% risk of neck injury with an abbreviated injury scale score ≥2 were shown in Seoi-nage than in either Ouchi-gari or Osoto-gari. In judo, when thrown by the Seoi-nage technique, serious neck injuries can occur as a result of neck compression that occurs when the head contacts the ground.

KTKatsunori Tanaka
Katsunori Tanaka
YMYasuki Motozawa
Yasuki Motozawa
KTKentaro Takahashi
Kentaro Takahashi
TMTetsuo Maki
Tetsuo Maki
MNMami Nakamura
Mami Nakamura
Masahito HitosugiMasahito Hitosugi
Masahito Hitosugi
Despite wearing a seat belt, pregnant drivers often suffer from negative fetal outcomes in the event of motor accidents. In order to maintain the safety of pregnant drivers and their fetuses, we assessed the severity of placental abruption caused by motor vehicle collisions using computer simulations. We employed a validated pregnant finite element model to determine the area of placental abruption. We investigated frontal vehicle collisions with a speed of 40 km/h or less involving restrained pregnant drivers with a gestational age of 30 weeks. For a crash speed of 40 km/h, the placental abruption area was 7.0% with a correctly positioned lap belt across the lower abdomen; it was 36.3% with the belt positioned at the umbilicus. The area of placental abruption depended on collision speed, but we found that with a correctly positioned belt it likely would not lead to negative fetal outcomes. We examined the effects on placental abruptions of reconfiguring seat belt width and force limiter setting. A wider lap belt and lower force limiter setting reduced the area of placental abruption to 3.5% and 1.1%, respectively; however, they allowed more forward movement upon collision. A 2.5 kN force limiter setting may be appropriate with respect to both forward movement and reduced placental abruption area. This study confirmed the importance of correctly using seat belts for pregnant drivers. It provides valuable evidence about improving safety equipment settings.

24 December 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
KTKatsunori Tanaka
Katsunori Tanaka
YMYasuki Motozawa
Yasuki Motozawa
KTKentaro Takahashi
Kentaro Takahashi
TMTetsuo Maki
Tetsuo Maki
Masahito HitosugiMasahito Hitosugi
Masahito Hitosugi
We clarified factors affecting the severity of placental abruption in motor vehicle collisions by quantitively analyzing the area of placental abruption in a numerical simulation of an unrestrained pregnant vehicle driver at collision velocities of 3 and 6 m/s. For the simulation, we constructed a novel finite element model of a small 30-week pregnant woman, which was validated anthropometrically using computed tomography data and biomechanically using previous examinations of post-mortem human subjects. In the simulation, stress in the elements of the utero–placental interface was computed, and those elements exceeding a failure criterion were considered to be abrupted. It was found that a doubling of the collision velocity increased the area of placental abruption 10-fold, and the abruption area was approximately 20% for a collision velocity of 6 m/s, which is lower than the speed limit for general roads. This result implies that even low-speed vehicle collisions have negative maternal and fetal outcomes owing to placental abruption without a seatbelt restraint. Additionally, contact to the abdomen, 30 mm below the umbilicus, led to a larger placental abruption area than contact at the umbilicus level when the placenta was located at the uterus fundus. The results support that a reduction in the collision speed and seatbelt restraint at a suitable position are important to decrease the placental abruption area and therefore protect a pregnant woman and her fetus in a motor vehicle collision.