Ann Mari Fjæraa

Ms. Ann Mari Fjæraa

Atmosphere and Climate Department, Norwegian Institute for Air Research (NILU), P.O box 100, 2027 Kjeller, Norway
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2024 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
Arno KeppensArno Keppens
Arno Keppens
SPSerena Di Pede
Serena Di Pede
DHDaan Hubert
Daan Hubert
JLJean-Christopher Lambert
Jean-Christopher Lambert
PVPepijn Veefkind
Pepijn Veefkind
CZClaus Zehner
Claus Zehner
The Sentinel-5 Precursor (S5P) satellite operated by the European Space Agency has carried the TROPOspheric Monitoring Instrument (TROPOMI) on a Sun-synchronous low-Earth orbit since 13 October 2017. The S5P mission has acquired more than 5 years of TROPOMI nadir ozone profile data retrieved from the level 0 to 1B processor version 2.0 and the level 1B to 2 optimal-estimation-based processor version 2.4.0. The latter is described in detail in this work, followed by the geophysical validation of the resulting ozone profiles for the period May 2018 to April 2023. Comparison of TROPOMI ozone profile data to co-located ozonesonde and lidar measurements used as references concludes to a median agreement better than 5 % to 10 % in the troposphere. The bias goes up to −15 % in the upper stratosphere (35–45 km) where it can exhibit vertical oscillations. The comparisons show a dispersion of about 30 % in the troposphere and 10 % to 20 % in the upper troposphere to lower stratosphere and in the middle stratosphere, which is close to mission requirements. Chi-square tests of the observed differences confirm on average the validity of the ex ante (prognostic) satellite and ground-based data uncertainty estimates in the middle stratosphere above about 20 km. Around the tropopause and below, the mean chi-square value increases up to about four, meaning that the ex ante TROPOMI uncertainty is underestimated. The information content of the ozone profile retrieval is characterised by about five to six vertical subcolumns of independent information and a vertical sensitivity (i.e. the fraction of the information that originates from the measurement) nearly equal to unity at altitudes from about 20 to 50 km, decreasing rapidly at altitudes above and below. The barycentre of the retrieved information is usually close to the nominal retrieval altitude in the 20–50 km altitude range, with positive and negative offsets of up to 10 km below and above this range, respectively. The effective vertical resolution of the profile retrieval usually ranges within 10–15 km, with a minimum close to 7 km in the middle stratosphere. Increased sensitivities and higher effective vertical resolutions are observed at higher solar zenith angles (above about 60°), as can be expected, and correlate with higher retrieved ozone concentrations. The vertical sensitivity of the TROPOMI tropospheric ozone retrieval is found to depend on the solar zenith angle, which translates into a seasonal and meridian dependence of the bias with respect to reference measurements. A similar although smaller effect can be seen for the viewing zenith angle. Additionally, the bias is negatively correlated with the surface albedo for the lowest three ozone subcolumns (0–18 km), despite the albedo's apparently slightly positive correlation with the retrieval degrees of freedom in the signal. For the 5 years of TROPOMI ozone profile data that are available now, an overall positive drift is detected for the same three subcolumns, while a negative drift is observed above (24–32 km), resulting in a negligible vertically integrated drift.

15 February 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Shridhar D. JawakShridhar D. Jawak
Shridhar D. Jawak
BABo N. Andersen
Bo N. Andersen
VPVeijo Pohjola
Veijo Pohjola
ØGØystein Godøy
Øystein Godøy
CHChristiane Hübner
Christiane Hübner
HLHeikki Lihavainen
Heikki Lihavainen
Svalbard Integrated Arctic Earth Observing System (SIOS) is an international partnership of research institutions studying the environment and climate in and around Svalbard. SIOS is developing an efficient observing system, where researchers share technology, experience, and data, work together to close knowledge gaps, and decrease the environmental footprint of science. SIOS maintains and facilitates various scientific activities such as the State of the Environmental Science in Svalbard (SESS) report, international access to research infrastructure in Svalbard, Earth observation and remote sensing services, training courses for the Arctic science community, and open access to data. This perspective paper highlights the activities of SIOS Knowledge Centre, the central hub of SIOS, and the SIOS Remote Sensing Working Group (RSWG) in response to the unprecedented situation imposed by the global pandemic coronavirus (SARS-CoV-2) disease 2019 (COVID-19). The pandemic has affected Svalbard research in several ways. When Norway declared a nationwide lockdown to decrease the rate of spread of the COVID-19 in the community, even more strict measures were taken to protect the Svalbard community from the potential spread of the disease. Due to the lockdown, travel restrictions, and quarantine regulations declared by many nations, most physical meetings, training courses, conferences, and workshops worldwide were cancelled by the first week of March 2020. The resumption of physical scientific meetings is still uncertain in the foreseeable future. Additionally, field campaigns to polar regions, including Svalbard, were and remain severely affected. In response to this changing situation, SIOS initiated several operational activities suitable to mitigate the new challenges resulting from the pandemic. This article provides an extensive overview of SIOS’s Earth observation (EO), remote sensing (RS) and other operational activities strengthened and developed in response to COVID-19 to support the Svalbard scientific community in times of cancelled/postponed field campaigns in Svalbard. These include (1) an initiative to patch up field data (in situ) with RS observations, (2) a logistics sharing notice board for effective coordinating field activities in the pandemic times, (3) a monthly webinar series and panel discussion on EO talks, (4) an online conference on EO and RS, (5) the SIOS’s special issue in the Remote Sensing (MDPI) journal, (6) the conversion of a terrestrial remote sensing training course into an online edition, and (7) the announcement of opportunity (AO) in airborne remote sensing for filling the data gaps using aerial imagery and hyperspectral data. As SIOS is a consortium of 24 research institutions from 9 nations, this paper also presents an extensive overview of the activities from a few research institutes in pandemic times and highlights our upcoming activities for the next year 2021. Finally, we provide a critical perspective on our overall response, possible broader impacts, relevance to other observing systems, and future directions. We hope that our practical services, experiences, and activities implemented in these difficult times will motivate other similar monitoring programs and observing systems when responding to future challenging situations. With a broad scientific audience in mind, we present our perspective paper on activities in Svalbard as a case study.

10 September 2021 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
FDFederico Dallo
Federico Dallo
DZDaniele Zannoni
Daniele Zannoni
JGJacopo Gabrieli
Jacopo Gabrieli
PCPaolo Cristofanelli
Paolo Cristofanelli
FCFrancescopiero Calzolari
Francescopiero Calzolari
CBCarlo Barbante
Carlo Barbante
This work presents results from an original open-source low-cost sensor (LCS) system developed to measure tropospheric O3 in a remote high altitude alpine site. Our study was conducted at the Col Margherita Observatory (2543 m above sea level), in the Italian Eastern Alps. The sensor system mounts three commercial low-cost O3/NO2 sensors that have been calibrated before field deployment against a laboratory standard (Thermo Scientific; 49i-PS), calibrated against the standard reference photometer no. 15 calibration scale of the World Meteorological Organization (WMO). Intra- and intercomparison between the sensors and a reference instrument (Thermo Scientific; 49c) have been conducted for 7 months from May to December 2018. The sensors required an individual calibration, both in laboratory and in the field. The sensor's dependence on the environmental meteorological variables has been considered and discussed. We showed that it is possible to reduce the bias of one LCS by using the average coefficient values of another LCS working in tandem, suggesting a way forward for the development of remote field calibration techniques. We showed that it is possible reconstruct the environmental ozone concentration during the loss of reference instrument data in situations caused by power outages. The evaluation of the analytical performances of this sensing system provides a limit of detection (LOD) <5 ppb (parts per billion), limit of quantification (LOQ) <17 ppb, linear dynamic range (LDR) up to 250 ppb, intra-Pearson correlation coefficient (PCC) up to 0.96, inter-PCC >0.8, bias >3.5 ppb and ±8.5 at 95 % confidence. This first implementation of a LCS system in an alpine remote location demonstrated how to obtain valuable data from a low-cost instrument in a remote environment, opening new perspectives for the adoption of low-cost sensor networks in atmospheric sciences.

15 January 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Shridhar D. JawakShridhar D. Jawak
Shridhar D. Jawak
VPVeijo Pohjola
Veijo Pohjola
AKAndreas Kääb
Andreas Kääb
BABo N. Andersen
Bo N. Andersen
MBMałgorzata Błaszczyk
Małgorzata Błaszczyk
AFAnn Mari Fjæraa
Ann Mari Fjæraa
Remarkable developments in the fields of earth observation (EO) satellites and remote sensing (RS) technology over the past four decades have substantially contributed to spatial, spectral, and temporal sampling

9 January 2024 in EGUsphere
Verified
Preprint
Open access
PDF file
Arno KeppensArno Keppens
Arno Keppens
SPSerena Di Pede
Serena Di Pede
DHDaan Hubert
Daan Hubert
JLJean-Christopher Lambert
Jean-Christopher Lambert
PVPepijn Veefkind
Pepijn Veefkind
CZClaus Zehner
Claus Zehner
The Sentinel-5 Precursor (S5P) satellite operated by the European Space Agency (ESA) carries the TROPOspheric Monitoring Instrument (TROPOMI) on a Sun-synchronous low-Earth orbit since October 13, 2017. The S5P mission has acquired more than five years of TROPOMI nadir ozone profile data retrieved from the Level-0-to-1B processor version 2.0 and the Level-1B-to-2 Optimal Estimation based processor version 2.4.0. The latter is described in detail in this work, followed by the geophysical validation of the resulting ozone profiles for the period May 2018 to April 2023. Comparison of TROPOMI ozone profile data to co-located ozonesonde and lidar measurements used as references, concludes to a median agreement better than 5 to 10 % in the troposphere. The bias goes up to -15 % in the upper stratosphere (35–45 km) where it can exhibit vertical oscillations. The comparisons show a dispersion of about 30 % in the troposphere and 10 to 20 % in the upper troposphere to lower stratosphere (UTLS) and in the middle stratosphere, which is close to mission requirements. Chi-square tests of the observed differences confirm on average the validity of the ex-ante (prognostic) satellite and ground-based data uncertainty estimates in the middle stratosphere, above about 20 km. Around the tropopause and below, the mean chi-square value increases up to about four, meaning that the ex-ante TROPOMI uncertainty is underestimated. The information content of the ozone profile retrieval is characterised by about five to six vertical sub-columns of independent information and a vertical sensitivity nearly equal to unity at altitudes from about 20 to 50 km, decreasing rapidly at altitudes above and below. The barycentre of the retrieved information is usually close to the nominal retrieval altitude in the 20–50 km altitude range, with positive and negative offsets of up to 10 km below and above this range, respectively. The effective vertical resolution of the profile retrieval usually ranges within 10–15 km, with a minimum close to 7 km in the middle stratosphere. Increased sensitivity and higher effective vertical resolution are observed at higher solar zenith angle (SZA, above about 60°), as can be expected, and correlate with higher retrieved ozone concentrations. The vertical sensitivity of the TROPOMI tropospheric ozone amount is found to depend on solar zenith angle, which translates into a seasonal and meridian dependence of its bias with respect to reference measurements. A similar although smaller effect can be seen for the viewing zenith angle (VZA). Additionally, the bias is negatively correlated with the surface albedo for the 6–12 km ozone subcolumn, despite the latter’s apparently slightly positive correlation with the retrieval degrees of freedom in the signal. For the five years of TROPOMI ozone profile data that are available now, an overall positive drift is detected for the lowest three subcolumns (0–18 km), while a negative drift is observed for the two subcolumns above (18–32 km), resulting in a negligible vertically integrated drift.

5 March 2021 in EGUsphere
Verified
Preprint
Open access
PDF file
FDFederico Dallo
Federico Dallo
DZDaniele Zannoni
Daniele Zannoni
JGJacopo Gabrieli
Jacopo Gabrieli
PCPaolo Cristofanelli
Paolo Cristofanelli
FCFrancescopiero Calzolari
Francescopiero Calzolari
CBCarlo Barbante
Carlo Barbante
The present work presents the results obtained using an original open-source low-cost sensor (LCS) system developed to measure tropospheric O3 in a remote high altitude alpine site. We conducted our study at the Col Margherita Observatory (2543 m a.s.l.), a World Meteorological Organization Global Atmosphere Watch Regional Station, located in the Italian Eastern Alps. The sensing system mounts three equivalent commercial low-cost sensors that have been calibrated using a laboratory standard (Thermo 49iPS), referenced to the Standard Reference Photometer #15 calibration scale by the WMO, before field deployment. Intra and inter-comparison between sensors and reference (Thermo 49c) have been conducted for seven months from May to December 2018. The sensors required an individual calibration, both in laboratory and in the field. The sensor's dependence on the environmental meteorological variables has been considered and discussed. The evaluation of the analytical performances of this sensing system provides an LOD < 5 ppb, LOQ < 17 ppb, LDR up to 250 ppb, intra-Pearson correlation coefficient (PCC) up to 0.96, inter-PCC > 0.8, bias > 3.5 ppb and ±8.5 at 95 % of confidence. Thanks to the first implementation of an LCS System in an alpine site, it has been demonstrated how it is possible to obtain valuable data from a low-cost instrument in a remote environment. This opens new perspectives for the adoption of a low-cost sensor network in atmospheric sciences.