Niranchan Paskaranandavadivel

Dr. Niranchan Paskaranandavadivel

Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2012 in BMC Gastroenterology
Verified
Journal Article
Open access
PDF file
RYRita Yassi
Rita Yassi
GOGregory O’gRady
Gregory O’gRady
NPNiranchan Paskaranandavadivel
Niranchan Paskaranandavadivel
PDPeng Du
Peng Du
TATim Angeli-Gordon
Tim Angeli-Gordon
JEJonathan C Erickson
Jonathan C Erickson
Background: Gastrointestinal contractions are controlled by an underlying bioelectrical activity. High-resolution spatiotemporal electrical mapping has become an important advance for investigating gastrointestinal electrical behaviors in health and motility disorders. However, research progress has been constrained by the low efficiency of the data analysis tasks. This work introduces a new efficient software package: GEMS (Gastrointestinal Electrical Mapping Suite), for analyzing and visualizing high-resolution multi-electrode gastrointestinal mapping data in spatiotemporal detail. Results: GEMS incorporates a number of new and previously validated automated analytical and visualization methods into a coherent framework coupled to an intuitive and user-friendly graphical user interface. GEMS is implemented using MATLAB®, which combines sophisticated mathematical operations and GUI compatibility. Recorded slow wave data can be filtered via a range of inbuilt techniques, efficiently analyzed via automated event-detection and cycle clustering algorithms, and high quality isochronal activation maps, velocity field maps, amplitude maps, frequency (time interval) maps and data animations can be rapidly generated. Normal and dysrhythmic activities can be analyzed, including initiation and conduction abnormalities. The software is distributed free to academics via a community user website and forum (http://sites.google.com/site/gimappingsuite). Conclusions: This software allows for the rapid analysis and generation of critical results from gastrointestinal high-resolution electrical mapping data, including quantitative analysis and graphical outputs for qualitative analysis. The software is designed to be used by non-experts in data and signal processing, and is intended to be used by clinical researchers as well as physiologists and bioengineers. The use and distribution of this software package will greatly accelerate efforts to improve the understanding of the causes and clinical consequences of gastrointestinal electrical disorders, through high-resolution electrical mapping.

1 November 2016 in American Journal of Physiology-Gastrointestinal and Liver Physiology
Verified
Journal Article
Closed access
PDF file
RBRachel Berry
Rachel Berry
TMTaimei Miyagawa
Taimei Miyagawa
NPNiranchan Paskaranandavadivel
Niranchan Paskaranandavadivel
PDPeng Du
Peng Du
TATim Angeli-Gordon
Tim Angeli-Gordon
LCLeo Cheng
Leo Cheng
High-resolution (HR) mapping has been used to study gastric slow-wave activation; however, the specific characteristics of antral electrophysiology remain poorly defined. This study applied HR mapping and computational modeling to define functional human antral physiology. HR mapping was performed in 10 subjects using flexible electrode arrays (128–192 electrodes; 16–24 cm2) arranged from the pylorus to mid-corpus. Anatomical registration was by photographs and anatomical landmarks. Slow-wave parameters were computed, and resultant data were incorporated into a computational fluid dynamics (CFD) model of gastric flow to calculate impact on gastric mixing. In all subjects, extracellular mapping demonstrated normal aboral slow-wave propagation and a region of increased amplitude and velocity in the prepyloric antrum. On average, the high-velocity region commenced 28 mm proximal to the pylorus, and activation ceased 6 mm from the pylorus. Within this region, velocity increased 0.2 mm/s per mm of tissue, from the mean 3.3 ± 0.1 mm/s to 7.5 ± 0.6 mm/s ( P < 0.001), and extracellular amplitude increased from 1.5 ± 0.1 mV to 2.5 ± 0.1 mV ( P < 0.001). CFD modeling using representative parameters quantified a marked increase in antral recirculation, resulting in an enhanced gastric mixing, due to the accelerating terminal antral contraction. The extent of gastric mixing increased almost linearly with the maximal velocity of the contraction. In conclusion, the human terminal antral contraction is controlled by a short region of rapid high-amplitude slow-wave activity. Distal antral wave acceleration plays a major role in antral flow and mixing, increasing particle strain and trituration.

28 June 2013 in The Journal of Physiology
Verified
Journal Article
Open access
PDF file
TATim Angeli-Gordon
Tim Angeli-Gordon
PDPeng Du
Peng Du
NPNiranchan Paskaranandavadivel
Niranchan Paskaranandavadivel
PJPatrick W.M. Janssen
Patrick W.M. Janssen
ABArthur Beyder
Arthur Beyder
GOGregory O’gRady
Gregory O’gRady
Key points: Extracellular recording techniques are commonly used to measure bioelectrical activity. However, the validity of gastrointestinal extracellular recordings has recently been challenged. In this joint experimental and modelling study, slow waves were recorded during contractile inhibition, biphasic and monophasic slow wave potentials were recorded simultaneously, and the biophysical basis of extracellular potentials was modelled with comparison to experimental data. The results showed that in vivo extracellular techniques reliably recorded slow waves in the absence of contractions, and potentials recorded using conventional serosal electrodes (biphasic) were concordant in phase and morphology with those recorded using suction electrodes (monophasic). Modelling further demonstrated that the morphology of experimental recordings is consistent with the biophysics underlying slow wave depolarisation. In total, these results demonstrate that gastrointestinal extracellular recordings are valid when performed and analysed correctly, reliably representing bioelectrical slow wave events. Motion suppression is not routinely required for in vivo extracellular studies. Abstract  Gastrointestinal extracellular recordings have been a core technique in motility research for a century. However, the bioelectrical basis of extracellular data has recently been challenged by claims that these techniques preferentially assay movement artifacts, cannot reproduce the underlying slow wave kinetics, and misrepresent the true slow wave frequency. These claims motivated this joint experimental–theoretical study, which aimed to define the sources and validity of extracellular potentials. In vivo extracellular recordings and video capture were performed in the porcine jejunum, before and after intra‐arterial nifedipine administration. Gastric extracellular recordings were recorded simultaneously using conventional serosal contact and suction electrodes, and biphasic and monophasic extracellular potentials were simulated in a biophysical model. Contractions were abolished by nifedipine, but extracellular slow waves persisted, with unchanged amplitude, downstroke rate, velocity, and downstroke width (P > 0.10 for all), at reduced frequency (24% lower; P= 0.03). Simultaneous suction and conventional serosal extracellular recordings were identical in phase (frequency and activation–recovery interval), but varied in morphology (monophasic vs. biphasic; downstroke rate and amplitude: P < 0.0001). Simulations demonstrated the field contribution of current flow to extracellular potential and quantified the effects of localised depolarisation due to suction pressure on extracellular potential morphology. In sum, these results demonstrate that gastrointestinal extracellular slow wave recordings cannot be explained by motion artifacts, and are of a bioelectrical origin that is highly consistent with the underlying biophysics of slow wave propagation. Motion suppression is shown to be unnecessary as a routine control in in vivo extracellular studies, supporting the validity of the extant gastrointestinal extracellular literature.

19 June 2012 in Neurogastroenterology & Motility
Verified
Journal Article
Closed access
PDF file
GOG. O’grady
G. O’grady
PDP. Du
P. Du
NPNiranchan Paskaranandavadivel
Niranchan Paskaranandavadivel
TATim Angeli-Gordon
Tim Angeli-Gordon
WLW. J. E. P. Lammers
W. J. E. P. Lammers
LCL. K. Cheng
L. K. Cheng

13 September 2012 in Neurogastroenterology & Motility
Verified
Journal Article
Closed access
PDF file
NPNiranchan Paskaranandavadivel
Niranchan Paskaranandavadivel
GOG. O’gRady
G. O’gRady
PDP. Du
P. Du
LCLeo Cheng
Leo Cheng

26 December 2011 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
NPNiranchan Paskaranandavadivel
Niranchan Paskaranandavadivel
GOGregory OrGrady
Gregory OrGrady
PDPeng Du
Peng Du
APAndrew J. Pullan
Andrew J. Pullan
LCLeo K. Cheng
Leo K. Cheng
High-resolution (HR) electrical mapping is an important clinical research tool for understanding normal and abnormal gastric electrophysiology. Analyzing velocities of gastric electrical activity in a reliable and accurate manner can provide additional valuable information for quantitatively and qualitatively comparing features across and within subjects, particularly during gastric dysrhythmias. In this study, we compared three methods of estimating velocities from HR recordings to determine which method was the most reliable for use with gastric HR electrical mapping. The three methods were 1) simple finite difference (FD) 2) smoothed finite difference (FDSM), and 3) a polynomial-based method. With synthetic data, the accuracy of the simple FD method resulted in velocity errors almost twice that of the FDSM and the polynomial-based method, in the presence of activation time error up to 0.5 s. With three synthetic cases under various noise types and levels, the FDSM resulted in average speed error of 3.2% and an average angle error of 2.0 ° and the polynomial-based method had an average speed error of 3.3% and an average angle error of 1.7 ° . With experimental gastric slow wave recordings performed in pigs, the three methods estimated similar velocities (6.3-7.3 mm/s), but the FDSM method had a lower standard deviation in its velocity estimate than the simple FD and the polynomial-based method, leading it to be the method of choice for velocity estimation in gastric slow wave propagation. An improved method for visualizing velocity fields is also presented.