Valerie Kuner

Mrs. Valerie Kuner

Graduate Student and Resident Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2021 in Journal of Hip Preservation Surgery
Verified
Journal Article
Open access
PDF file
CZCorinne Andrea Zurmühle
Corinne Andrea Zurmühle
VKValerie Kuner
Valerie Kuner
JMJames McInnes
James McInnes
DPDominik H Pfluger
Dominik H Pfluger
MBMartin Beck
Martin Beck
Currently, much is debated on the optimal treatment of borderline hips, being in the continuum between stable and unstable hips. The diagnosis of stability is often difficult but is a prerequisite for further treatment. Analysis includes a variety of radiographic parameters. We observed that unstable hips often had a crescent-like gadolinium collection in the postero-inferior joint space. We therefore questioned if the ‘crescent sign’ could be an indicator for hip instability? A retrospective comparative study was conducted including 56 hips in the instability group (treated with PAO) and 70 hips with femoroacetabular impingement (FAI) as control group. Based on standard radiographic parameters and magnetic resonance imaging (MRI), the association between hip instability and the ‘crescent sign’ was analyzed. For univariate group comparisons, the non-parametric Wilcoxon two sample test was used. Association between discrete variables was examined by means of chi-square tests. To examine predictive variables, logistic regression models were carried out. Most hips with a crescent sign belong to the instability group. A crescent sign has a sensitivity of 73.3% and specificity of 93% for instability. Based on our results, the crescent sign is a factor that is more prevalent in unstable hips. However, its absence does not exclude instability of the hip. If present, the specificity speaks strongly in favor for instability of the hip.

21 March 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
VKValerie Kuner
Valerie Kuner
NVNicole van Veelen
Nicole van Veelen
SSStephanie Studer
Stephanie Studer
BWBryan van de Wall
Bryan van de Wall
JFJürgen Fornaro
Jürgen Fornaro
BLBjörn-Christian Link
Björn-Christian Link
Early administration of a pelvic circumferential compression device (PCCD) is recommended for suspected pelvic trauma. This study was conducted to evaluate the prevalence of PCCD in patients with pelvic fractures assigned to the resuscitation room (RR) of a Level I trauma center. Furthermore, correct application of the PCCD as well as associated injuries with potential clinical sequelae were assessed. All patients with pelvic fractures assigned to the RR of a level one trauma center between 2016 and 2017 were evaluated retrospectively. Presence and position of the PCCD on the initial trauma scan were assessed and rated. Associated injuries with potential adverse effects on clinical outcome were analysed. Seventy-seven patients were included, of which 26 (34%) had a PCCD in place. Eighteen (23%) patients had an unstable fracture pattern of whom ten (56%) had received a PCCD. The PCCD was correctly placed in four (15%) cases, acceptable in 12 (46%) and incorrectly in ten (39%). Of all patients with pelvic fractures (n = 77, 100%) treated in the RR, only one third (n = 26, 34%) had a PCCD. In addition, 39% of PCCDs were positioned incorrectly. Of the patients with unstable pelvic fractures (n = 18, 100%), more than half either did not receive any PCCD (n = 8, 44%) or had one which was inadequately positioned (n = 2, 11 %). These results underline that preclinical and clinical education programs on PCCD indication and application should be critically reassessed.