Valentina Catto

Dr. Valentina Catto

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
VCValentina Catto
Valentina Catto
Silvia Fare'Silvia Fare'
Silvia Fare'
ICIrene Cattaneo
Irene Cattaneo
MFMarina Figliuzzi
Marina Figliuzzi
AAAntonio Alessandrino
Antonio Alessandrino
MariaCristina TanziMariaCristina Tanzi
MariaCristina Tanzi

29 September 2020 in Circulation
Verified
Journal Article
Closed access
PDF file
Michela CasellaMichela Casella
Michela Casella
ARAntonio Dello Russo
Antonio Dello Russo
MBMarco Bergonti
Marco Bergonti
VCValentina Catto
Valentina Catto
ECEdoardo Conte
Edoardo Conte
CTClaudio Tondo
Claudio Tondo
Background: Electroanatomic voltage mapping (EVM) is a promising modality for guiding endomyocardial biopsies (EMBs). However, few data support its feasibility and safety. We now report the largest cohort of patients undergoing EVM-guided EMBs to show its diagnostic yield and to compare it with a cardiac magnetic resonance (CMR)–guided approach. Methods: We included 162 consecutive patients undergoing EMB at our institution from 2010 to 2019. EMB was performed in pathological areas identified at EVM and CMR. CMR and EVM sensitivity and specificity regarding the identification of pathological substrates of myocardium were evaluated according to EMB results. Results: Preoperative CMR showed late gadolinium enhancement in 70% of the patients, whereas EVM identified areas of low voltage in 61%. Right (73%), left (19%), or both ventricles (8%) underwent sampling. EVM proved to have sensitivity similar to CMR (74% versus 77%), with specificity being 70% and 47%, respectively. In 12 patients with EMB-proven cardiomyopathy, EVM identified pathological areas that had been undetected at CMR evaluation. Sensitivity of pooled EVM and CMR was as high as 95%. EMB analysis allowed us to reach a new diagnosis, different from the suspected clinical diagnosis, in 39% of patients. The complications rate was low, mostly related to vascular access, with no patients requiring urgent management. Conclusions: EVM proved to be a promising tool for targeted EMB because of its sensitivity and specificity for identification of myocardial pathological substrates. EVM was demonstrated to have accuracy similar to CMR. EVM and CMR together conferred a positive predictive value of 89% on EMB.

20 November 2015 in European Heart Journal
Verified
Journal Article
Open access
PDF file
Elena SommarivaElena Sommariva
Elena Sommariva
SBS. Brambilla
S. Brambilla
CCC. Carbucicchio
C. Carbucicchio
EGElisa Gambini
Elisa Gambini
Viviana MeravigliaViviana Meraviglia
Viviana Meraviglia
Giulio PompilioGiulio Pompilio
Giulio Pompilio
Arrhythmogenic cardiomyopathy (ACM) is a genetic disorder mainly due to mutations in desmosomal genes, characterized by progressive fibro-adipose replacement of the myocardium, arrhythmias, and sudden death. It is still unclear which cell type is responsible for fibro-adipose substitution and which molecular mechanisms lead to this structural change. Cardiac mesenchymal stromal cells (C-MSC) are the most abundant cells in the heart, with propensity to differentiate into several cell types, including adipocytes, and their role in ACM is unknown. The aim of the present study was to investigate whether C-MSC contributed to excess adipocytes in patients with ACM. We found that, in ACM patients' explanted heart sections, cells actively differentiating into adipocytes are of mesenchymal origin. Therefore, we isolated C-MSC from endomyocardial biopsies of ACM and from not affected by arrhythmogenic cardiomyopathy (NON-ACM) (control) patients. We found that both ACM and control C-MSC express desmosomal genes, with ACM C-MSC showing lower expression of plakophilin (PKP2) protein vs. controls. Arrhythmogenic cardiomyopathy C-MSC cultured in adipogenic medium accumulated more lipid droplets than controls. Accordingly, the expression of adipogenic genes was higher in ACM vs. NON-ACM C-MSC, while expression of cell cycle and anti-adipogenic genes was lower. Both lipid accumulation and transcription reprogramming were dependent on PKP2 deficiency. Cardiac mesenchymal stromal cells contribute to the adipogenic substitution observed in ACM patients' hearts. Moreover, C-MSC from ACM patients recapitulate the features of ACM adipogenesis, representing a novel, scalable, patient-specific in vitro tool for future mechanistic studies.

1 January 2018 in Pharmacological Research
Verified
Journal Article
Closed access
PNPatrizia Nigro
Patrizia Nigro
BBBeatrice Bassetti
Beatrice Bassetti
LCLaura Cavallotti
Laura Cavallotti
VCValentina Catto
Valentina Catto
CCCorrado Carbucicchio
Corrado Carbucicchio
Giulio PompilioGiulio Pompilio
Giulio Pompilio

7 April 2015 in Journal of Applied Biomaterials & Functional Materials
Verified
Journal Article
Open access
ENElham Naghashzargar
Elham Naghashzargar
Silvia Fare'Silvia Fare'
Silvia Fare'
VCValentina Catto
Valentina Catto
SBSerena Bertoldi
Serena Bertoldi
DSDariush Semnani
Dariush Semnani
MariaCristina TanziMariaCristina Tanzi
MariaCristina Tanzi
A novel biodegradable nano/micro hybrid structure was obtained by electrospinning P3HB or PCL nanofibers onto a twisted silk fibroin (SF) structure, with the aim of fabricating a suitable scaffold for tendon and ligament tissue engineering. The electrospinning (ES) processing parameters for P3HB and PCL were optimized on 2D samples, and applied to produce two different nano/micro hybrid constructs (SF/ES-PCL and SF/ES-P3HB). Morphological, chemico-physical and mechanical properties of the novel hybrid scaffolds were evaluated by SEM, ATR FT-IR, DSC, tensile and thermodynamic mechanical tests. The results demonstrated that the nanofibers were tightly wrapped around the silk filaments, and the crystallinity of the SF twisted yarns was not influenced by the presence of the electrospun polymers. The slightly higher mechanical properties of the hybrid constructs confirmed an increase of internal forces due to the interaction between nano and micro components. Cell culture tests with L929 fibroblasts, in the presence of the sample eluates or in direct contact with the hybrid structures, showed no cytotoxic effects and a good level of cytocompatibility of the nano/micro hybrid structures in term of cell viability, particularly at day 1. Cell viability onto the nano/micro hybrid structures decreased from the first to the third day of culture when compared with the control culture plastic, but appeared to be higher when compared with the uncoated SF yarns. Although additional in vitro and in vivo tests are needed, the original fabrication method here described appears promising for scaffolds suitable for tendon and ligament tissue engineering.

5 June 2018 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
Michela CasellaMichela Casella
Michela Casella
ARAntonio Dello Russo
Antonio Dello Russo
EREleonora Russo
Eleonora Russo
VCValentina Catto
Valentina Catto
FPFrancesca Pizzamiglio
Francesca Pizzamiglio
CTClaudio Tondo
Claudio Tondo
Background: Only a few studies have systematically evaluated fluoroscopy data of electrophysiological and device implantation procedures. Aims of this study were to quantify ionizing radiation exposure for electrophysiological/device implantation procedures in a large series of patients and to analyze the x‐ray exposure trend over years and radiation exposure in patients undergoing atrial fibrillation ablation considering different technical aspects. Methods and Results: We performed a retrospective analysis of all electrophysiological/device implantation procedures performed during the past 7 years in a modern, large‐volume laboratory. We reported complete fluoroscopy data on 8150 electrophysiological/device implantation procedures (6095 electrophysiological and 2055 device implantation procedures); for each type of procedure, effective dose and lifetime attributable risk of cancer incidence and mortality were calculated. Over the 7‐year period, we observed a significant trend reduction in fluoroscopy time, dose area product, and effective dose for all electrophysiological procedures ( P <0.001) and a not statistically significant trend reduction for device implantation procedures. Analyzing 2416 atrial fibrillation ablations, we observed a significant variability of fluoroscopy time, dose area product and effective dose among 7 different experienced operators ( P <0.0001) and a significant reduction of fluoroscopy use over time ( P <0.0001) for all of them. Considering atrial fibrillation ablation techniques, fluoroscopy time was not different ( P = 0.74) for radiofrequency catheter ablation in comparison with cryoablation, though cryoablation was still associated with higher dose area product and effective dose values ( P <0.001). Conclusions: Electrophysiological procedures involve a nonnegligible x‐ray use, leading to an increased risk of malignancy. Awareness of radiation‐related risk, together with technological advances, can successfully optimize fluoroscopy use.