Background: Association of premature ventricular complexes (PVC) with left ventricular systolic dysfunction (LVSD) and efficacy of catheter ablation treatment have been demonstrated in studies. The role of left atrial (LA) mechanics in the etiopathogenesis of PVC-induced cardiomyopathy (PVC-CMP) as well as changes in LA mechanics with catheter ablation have not been studied before. Methods: A total number of 61 patients (Mean Age 43 ± 3) with idiopathic outflow tract (OT) PVCs undergoing radiofrequency catheter ablation (RFCA) were enrolled. ECG, 24 h Holter, and echocardiographic evaluation with left ventricular (LV) diastolic functions and LA volumetric assessments were performed before and three months after RFCA. Results: Along with a marginal increase in left ventricle ejection fraction (LVEF), improvement in diastolic functions and left atrial mechanics were observed in the study (LVEF 53 ± 7 versus 57 ± 6, p < 0.01) in short-term follow-up. The frequency of LV diastolic dysfunction (LVDD) decreased with catheter ablation (n = 5 to 0, p = 0.02). The overall LA function improved. Left atrium passive and overall emptying fraction (LAEF) increased significantly (0.32 ± 0.04 to 0.41 ± 0.04, p < 0.05 and 0.62 ± 0.04 to 0.65 ± 0.004, p < 0.05, respectively). Active LAEF decreased significantly (0.29 ± 0.005 to 0.24 ± 0.006, p < 0.05). Conclusions: The results of this study are indicative of “PVC-induced atriomyopathy” which responds to RFCA in short-term follow-up. Atrial dysfunction might play a role in symptoms and etiopathogenesis of LVSD.
Introduction The pathophysiology of isolated coronary artery ectasia (iCAE) has not been clearly identified, although multiple abnormalities, including arteritis, endothelial dysfunction, and vascular destruction, have been reported. In this study, we aimed to analyze serum cystatin C concentrations in patients with iCAE and controls. Methods Forty-seven patients with iCAE (mean age: 55.9 ± 11.5) and 32 individuals with normal coronary angiography (mean age: 57.8.1 ± 9.6) were included in the study. Plasma cystatin C levels were measured by using the principle of particle-enhanced turbidimetric immunoassay (PETIA). Results Serum cystatin C concentrations were significantly lower in patients with iCAE compared with the control group (0.98 ± 0.17 mg/L versus 1.17 ± 2.6 mg/L, p-value = 0.001). A significantly positive relationship was found between serum cystatin C levels and creatinine and high-sensitivity C-reactive protein (hs-CRP) levels in both groups (r-value = 0.288, p-value = 0.005, r-value = 0.143, p-value = 0.007, respectively). In multivariate logistic regression analysis, serum cystatin C level found to be a significant predictor for the presence of iCAE (OR: 0.837, CI: 95% (0.341 - 1.637), p-value = 0.013). Receiver operating characteristic (ROC) analysis determined that a cystatin C value < 1.02 mg/L had a sensitivity of 56% and a specificity of 78% for the prediction of ectasia. Conclusion We conclude that cystatin C independently can be a useful predictor for the presence of iCAE.
Primary tumors of the heart are very uncommon and approximately 25% of them are malign. Primary cardiac lymphomas account for approximately 4% of the primary cardiac tumors. Both B- and T-cell lymphomas have been reported. We report the case of a 75-year-old male who was referred to our hospital complaining of fatigue, dyspnea and swelling in the abdomen. Transthoracic echocardiography revealed a mobile 5.0×4.3 cm mass in the right atrial cavity impinging tricuspid valve. Surgery was performed and the mass was resected. The pathological and histological examination of the removed mass showed diffuse large B-cell lymphoma.