Sandeep Dhallu

Dr. Sandeep Dhallu

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
SFSimon S.M. Fung
Simon S.M. Fung
RSRosalind M.K. Stewart
Rosalind M.K. Stewart
Sandeep DhalluSandeep Dhallu
Sandeep Dhallu
DSDawn A. Sim
Dawn A. Sim
PKPearse A. Keane
Pearse A. Keane
STStephen J. Tuft
Stephen J. Tuft

1 August 2014 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
EBEmma J. Berrow
Emma J. Berrow
James S. WolffsohnJames S. Wolffsohn
James S. Wolffsohn
PBParamdeep S. Bilkhu
Paramdeep S. Bilkhu
Sandeep DhalluSandeep Dhallu
Sandeep Dhallu
SNShehzad A. Naroo
Shehzad A. Naroo
SSSunil Shah
Sunil Shah
PURPOSE: To assess the visual performance and subjective experience of eyes implanted with a new bi-aspheric, segmented, multifocal intraocular lens: the Mplus X (Topcon Europe Medical, Capelle aan den IJssel, Netherlands). METHODS: Seventeen patients (mean age: 64.0 ± 12.8 years) had binocular implantation (34 eyes) with the Mplus X. Three months after the implantation, assessment was made of: manifest refraction; uncorrected and corrected distance visual acuity; uncorrected and distance corrected near visual acuity; defocus curves in photopic conditions; contrast sensitivity; halometry as an objective measure of glare; and patient satisfaction with unaided near vision using the Near Acuity Visual Questionnaire. RESULTS: Mean residual manifest refraction was −0.13 ± 0.51 diopters (D). Twenty-five eyes (74%) were within a mean spherical equivalent of ±0.50 D. Mean uncorrected distance visual acuity was +0.10 ± 0.12 logMAR monocularly and 0.02 ± 0.09 logMAR binocularly. Thirty-two eyes (94%) could read 0.3 or better without any reading correction and all patients could read 0.3 or better with a reading correction. Mean monocular uncorrected near visual acuity was 0.18 ± 0.16 logMAR, improving to 0.15 ± 0.15 logMAR with distance correction. Mean binocular uncorrected near visual acuity was 0.11 ± 0.11 logMAR, improving to 0.09 ± 0.12 logMAR with distance correction. Mean binocular contrast sensitivity was 1.75 ± 0.14 log units at 3 cycles per degree, 1.88 ± 0.20 log units at 6 cycles per degree, 1.66 ± 0.19 log units at 12 cycles per degree, and 1.11 ± 0.20 log units at 18 cycles per degree. Mean binocular and monocular halometry showed a glare profile of less than 1° of debilitating light scatter. Mean Near Acuity Visual Questionnaire Rasch score (0 = no difficulty, 100 = extreme difficulty) for satisfaction for near vision was 20.43 ± 14.64 log-odd units. CONCLUSIONS: The Mplus X provides a good visual outcome at distance and near with minimal dysphotopsia. Patients were very satisfied with their uncorrected near vision. [ J Refract Surg. 2014;30(9):584–588.]

27 July 2016 in BMJ Open
Verified
Journal Article
Open access
PDF file
ADAlexander C Day
Alexander C Day
Sandeep DhalluSandeep Dhallu
Sandeep Dhallu
VMVincenzo Maurino
Vincenzo Maurino
MWMark R Wilkins
Mark R Wilkins
Objectives To describe the initial outcomes following installation of a cataract surgery laser system. Setting National Health Service cataract surgery day care unit in North London, UK. Participants 158 eyes of 150 patients undergoing laser-assisted cataract surgery. Interventions Laser cataract surgery using the AMO Catalys femtosecond laser platform. Primary and secondary outcome measures Primary outcome measure: intraoperative complications including anterior and posterior capsule tears. Secondary outcome measures: docking to the laser platform, successful treatment delivery, postoperative visual acuities. Results Mean case age was 67.7±10.8 years (range 29–88 years). Docking was successful in 94% (148/158 cases), and in 4% (6/148 cases) of these, the laser delivery was aborted part way during delivery due to patient movement. A total of 32 surgeons, of grades from junior trainee to consultant, performed the surgeries. Median case number per surgeon was 3 (range from 1–20). The anterior capsulotomy was complete in 99.3% of cases, there were no anterior capsule tears (0%). There were 3 cases with posterior capsule rupture requiring anterior vitrectomy, and 1 with zonular dialysis requiring anterior vitrectomy (4/148 eyes, 2.7%). These 4 cases were performed by trainee surgeons, and were either their first laser cataract surgery (2 surgeons) or their first and second laser cataract surgeries (1 surgeon). Conclusions Despite the learning curve, docking and laser delivery were successfully performed in almost all cases, and surgical complication rates and visual outcomes were similar to those expected based on national data. Complications were predominately confined to trainee surgeons, and with the exception of intraoperative pupil constriction appeared unrelated to the laser-performed steps.

28 June 2019 in Vision
Verified
Journal Article
Open access
PDF file
Sandeep DhalluSandeep Dhallu
Sandeep Dhallu
ASAmy L Sheppard
Amy L Sheppard
TDTom Drew
Tom Drew
TMToshifumi Mihashi
Toshifumi Mihashi
JZJuan F. Zapata-Díaz
Juan F. Zapata-Díaz
James S. WolffsohnJames S. Wolffsohn
James S. Wolffsohn
The key determinants of the range of clear focus in pre-presbyopes and their relative contributions to the difference between subjective range of focus and objective accommodation assessments have not been previously quantified. Fifty participants (aged 33.0 ± 6.4 years) underwent simultaneous monocular subjective (visual acuity measured with an electronic test-chart) and objective (dynamic accommodation measured with an Aston open-field aberrometer) defocus curve testing for lenses between +2.00 to −10.00 DS in +0.50 DS steps in a randomized order. Pupil diameter and ocular aberrations (converted to visual metrics normalized for pupil size) at each level of blur were measured. The difference between objective range over which the power of the crystalline lens changes and the subjective range of clear focus was quantified and the results modelled using pupil size, refractive error, tolerance to blur, and ocular aberrations. The subjective range of clear focus was principally accounted for by age (46.4%) and pupil size (19.3%). The objectively assessed accommodative range was also principally accounted for by age (27.6%) and pupil size (15.4%). Over one-quarter (26.0%) of the difference between objective accommodation and subjective range of clear focus was accounted for by age (14.0%) and spherical aberration at maximum accommodation (12.0%). There was no significant change in the objective accommodative response (F = 1.426, p = 0.229) or pupil size (F = 0.799, p = 0.554) of participants for levels of defocus above their amplitude of accommodation. Pre-presbyopes benefit from an increased subjective range of clear vision beyond their objective accommodation due in part to neural factors, resulting in a measured depth-of-focus of, on average, 1.0 D.

29 September 2024 in Medicina
Verified
Journal Article
Open access
PDF file
JPJustin E. Pettayil
Justin E. Pettayil
SHSamya Haque
Samya Haque
MFMohammed Fardin
Mohammed Fardin
Sandeep DhalluSandeep Dhallu
Sandeep Dhallu
Sònia Travé-HuarteSònia Travé-Huarte
Sònia Travé-Huarte
DDDebarun Dutta
Debarun Dutta
Background and Objectives: Infrared light is used to image the Meibomian glands through their thermal profile. This study aimed to investigate the effects of a combination of heating and an eyelid massage on Meibomian gland visibility and tear film parameters. Materials and Methods: Twenty-four participants (26 ± 6.9 years) were enrolled in this prospective study, which involved imaging the Meibomian glands of both the lower and upper eyelid and assessing the non-invasive breakup time (NIBUT), tear meniscus height (TMH), and blink rate (using the CA-800, Topcon) at baseline after five minutes of eyelid warming followed by a five-minute eyelid massage. The second session, which was randomised in sequence, repeated the same measurements but without the inclusion of any eyelid warming or massage as the control condition. Results: While there was no change in lower lid Meibomian gland appearance as a result of eyelid heating, eyelid massage, or multiple lid eversion (median 2.0, range 0.0 to 4.0; p = 0.782), there was a change in upper lid appearance 5 min after heating and lid massage (p = 0.025), but again, multiple lid eversion had no effect (p > 0.05). The NIBUT decreased on second lid eversion (p = 0.049), although this was not evident on the third lid eversion (p = 0.090). The effect on NIBUT was also apparent with heating (p = 0.034 immediately after) but was sustained with 5 min of eyelid massage (p = 0.031). The TMH increased with heating (p < 0.001), and this effect was sustained with 5 min of eyelid massage (p = 0.011), but there was no lid eversion effect (p > 0.05). The blink rate was unaffected by heating, eyelid massage, or multiple eversions of the eyelids (median 24 blinks/min, range 8 to 59 blinks/min; p = 0.61). Conclusions: Eyelid warming can increase the visibility of the Meibomian glands, although this effect was only observed with upper lid imaging and the effect dissipated after 5 min of eyelid massage. Warming and massage also disrupt the tear film, as does multiple lid eversion, emphasising the need to use the least invasive tear film assessment techniques first.

11 October 2025 in Medicina
Verified
Journal Article
Open access
PDF file
Sandeep DhalluSandeep Dhallu
Sandeep Dhallu
MPMolly J Pritchard
Molly J Pritchard
DCDavid YS Chau
David YS Chau
SKStewart Brian Kirton
Stewart Brian Kirton
Ocular surface disorders such as dry eye disease are an increasingly encountered ophthalmic disorder, in which signs and symptoms can vary significantly from one patient to the next. Severe dry eye can be a challenge for the ophthalmic practitioner to manage. Contemporary management options are wide-ranging and include topical treatments, contact lenses, and surgical options. More recently, newer stem cell-based therapies have emerged, and early reports have shown promising outcomes. Meanwhile, other novel approaches, such as the eggshell membrane, are currently in development, and while no studies have yet reported on its use in ophthalmic applications, further developments in this area are expected. However, longer-term studies are needed in order to fully assess the safety and efficacy of these newer treatments. There are an increasing number of treatment options available for ocular surface disorders. This article provides an overview of some of the current treatment options that are available for severe ocular surface disorders, including dry eye disease, as well as insight into applications that are currently in development, which may show potential in the future.