Byong Jeong Choi

Dr. Byong Jeong Choi

Kyonggi University
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SLSu-Hyeon Lee
Su-Hyeon Lee
BCByong Jeong Choi
Byong Jeong Choi
Studies involving the mechanical properties of high-strength steel (HSS) at elevated temperatures have received considerable attention in recent years. However, current research on HSS at high temperatures is lacking. As a result, the design of fire-protective steel structures with high standards is not sufficiently conservative or safe. This study investigates the effect that elevated temperatures have on the mechanical properties of ASTM A572 Gr. 50 and 60 steels. Reduction factors for the yield strength, tensile strength, and elastic modulus were derived and compared with the standard (AISC, EN1993-1-2) and previous studies (NIST). This study also provides extensive data on the reduction factors for the yield strength, tensile strength, and elastic modulus of mild steel (MS), HSS, and very-high-strength steel (VHSS). The reduction factor for the yield strength was analyzed by expanding the strain level up to 20%. Equations for the yield strength, tensile strength, and elastic modulus were proposed. In future studies, various strains should be analyzed according to the grade of the steel, with the derivation of a reduction factor that considers the plastic strain of the steel. Hence, the findings reported in this study generated a database that can be applied to fire safety design or performance-based fire-resistant design.

1 December 2016 in Journal of the Earthquake Engineering Society of Korea
Verified
Journal Article
Closed access
GEGraduate School of Architectural Engineering
Graduate School of Architectural Engineering
SLSu Hyeon Lee
Su Hyeon Lee
TCTae Gu Cho
Tae Gu Cho
HLHwan Taek Lim
Hwan Taek Lim
BCByong Jeong Choi
Byong Jeong Choi

28 February 2019 in Journal of the Korean Society of Hazard Mitigation
Verified
Journal Article
Open access
PDF file
KJKyung-Hwan Ji
Kyung-Hwan Ji
BCByong Jeong Choi
Byong Jeong Choi
Underground wall construction that is an under-the-frame construction constituting the skeleton of a building, involves a construction with a high outer wall, poor working environment, and high safety risk. A conventional formwork method exists for such construction. The existing method requires several technicians working in different areas such as scaffolding, rebar construction, formwork construction, and concrete casting construction. In addition, it requires longer construction periods with higher risk of accidents and deterioration in the quality. To overcome such drawbacks, in this work, mega double wall construction method that involves a factory-made precast form, has been used for the initial design stage after discussions between the client, designer, and builder. This method reduces the number of required technicians and construction period, lowers the risk of accidents, and improves the quality, and is a result of introducing the concept of design for safety at the early design stage. In the future, it is necessary to introduce the concept of design for safety not only for underground wall construction, but also for finishing work, thus, allowing for safer overall construction.

5 April 2021 in Materials
Verified
Journal Article
Open access
PDF file
SLSu-Hyeon Lee
Su-Hyeon Lee
BCByong Jeong Choi
Byong Jeong Choi
It is very important to understand the residual performance of a structure for repair, retrofit, and reuse of a building after a fire. In this study, an experiment is conducted on the residual performance of real-scale siliceous aggregates-based reinforced concrete (RC) wall-slab connection (WSC) after the fire, using the simple calculation method (SCM) of standards (Eurocode, ACI, and NIST) for comparison and analysis. A description of the WSC specimen and detailed methods for the experiment are introduced. The fire test is conducted according to the fire scenario by dividing it into one-sided and two-sided heating based on the wall. In the post-fire residual performance test, the load–displacement and moment-deflection angle relationship according to the fire time are derived and discussed. In addition, the residual mechanical properties after the fire are derived for the 35 MPa siliceous concrete used in the wall-slab specimen. The load and moment, derived using SCM, are compared with the experimental results. Our results show that the one-sided heating test result is close to that of Eurocode’s SCM, and the two-sided heating test result is close to that of ACI (NIST)’s SCM. This study provides a database on the residual strength through a real-scale fire test and standard comparison.

5 December 2014 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
HPHo Young Park
Ho Young Park
BCByong Jeong Choi
Byong Jeong Choi
The domestic research of the steel plate concrete structures have been focused on the nuclear power plant structures that usually require high strength. This research tried to establish some basic design information of SC structures using cementless concrete. This paper studied on the compressive characteristics and effective length factors subjected to the concentrated compression loadings. The experimental results in average was 98% of the value calculated from the equation in KEPIC-SNG, and the experimental results was 92% of the value calculated from the equation in JEAG-4618.

20 February 2014 in Journal of the Korea Institute of Building Construction
Verified
Journal Article
Closed access
KHKwon-Gyu Han
Kwon-Gyu Han
HPHo-Young Park
Ho-Young Park
KHKyung-Bo Han
Kyung-Bo Han
BCByong Jeong Choi
Byong Jeong Choi