Ming-Che Lu

Prof. Dr. Ming-Che Lu

Chaoyang University of Technology, Taiwan

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CLChien-Hua Lin
Chien-Hua Lin
Ming-Che LuMing-Che Lu
Ming-Che Lu
Su-Fen YangSu-Fen Yang
Su-Fen Yang
MLMing-Yung Lee
Ming-Yung Lee
Automation in the service industry is emerging as a new wave of industrial revolution. Standardization and consistency of service quality is an important part of the automation process. The quality control methods widely used in the manufacturing industry can provide service quality measurement and service process monitoring. In particular, the control chart as an online monitoring technique can be used to quickly detect whether a service process is out of control. However, the control of the service process is more difficult than that of the manufacturing process because the variability of the service process comes from widespread and complex factors. First of all, the distribution of the service process is usually non-normal or unknown. Moreover, the skewness of the process distribution can be time-varying, even if the process is in control. In this study, a Bayesian procedure is applied to construct a Phase II exponential weighted moving average (EWMA) control chart for monitoring the variance of a distribution-free process. We explore the sampling properties of the new monitoring statistic, which is suitable for monitoring the time-varying process distribution. The average run lengths (ARLs) of the proposed Bayesian EWMA variance chart are calculated, and they show that the chart performs well. The simulation studies for a normal process, exponential process, and the mixed process of normal and exponential distribution prove that our chart can quickly detect any shift of a process variance. Finally, a numerical example of bank service time is used to illustrate the application of the proposed Bayesian EWMA variance chart and confirm the performance of the process control.

14 December 2021 in Quality and Reliability Engineering International
Verified
Journal Article
Closed access
PDF file
Su-Fen YangSu-Fen Yang
Su-Fen Yang
Barry ArnoldBarry Arnold
Barry Arnold
YLYen‐Ling Liu
Yen‐Ling Liu
Ming-Che LuMing-Che Lu
Ming-Che Lu
Shin-Li LuShin-Li Lu
Shin-Li Lu

17 June 2024 in Quality and Reliability Engineering International
Verified
Journal Article
Closed access
PDF file
Ming-Che LuMing-Che Lu
Ming-Che Lu
SYSu‐Fen Yang
Su‐Fen Yang

27 August 2021 in Journal of Statistical Computation and Simulation
Verified
Journal Article
Closed access
Ming-Che LuMing-Che Lu
Ming-Che Lu
DCDong-Shang Chang
Dong-Shang Chang
SYSu-Fen Yang
Su-Fen Yang
The two-parameter Birnbaum–Saunders distribution was derived to describe the failure time from a process of fatigue crack growth. The scale parameter is also the median of the distribution. The inferences for the median of the distribution are mostly based on the maximum likelihood methods and subject to large-sample requirements. In this paper, we develop the exact small-sample confidence intervals of the median of the distribution when the shape parameter is known and unknown, respectively. Moreover, an alternative consistent estimator with an explicit form for the median of the distribution is provided in this study. Finally, we develop the hypothesis testing for the median of the distribution based on a small sample. The Monte Carlo simulations are further carried out to prove the power of the proposed test well performance.

1 April 2012 in International Review of Economics & Finance
Verified
Journal Article
Closed access
CCChing-Lung Chen
Ching-Lung Chen
Ming-Che LuMing-Che Lu
Ming-Che Lu
GYGili Yen
Gili Yen

21 October 2025 in Processes
Verified
Journal Article
Open access
PDF file
Ming-Che LuMing-Che Lu
Ming-Che Lu
Su-Fen YangSu-Fen Yang
Su-Fen Yang
Statistical process control may lead to false detection results in the presence of measurement error, so it is necessary to deal with the effect of measurement error. The Bayesian exponentially weighted moving average (EWMA) variability control chart, first proposed by Lin et al., is a distribution-free control chart, and it can effectively monitor process variance even if the process skewness varies with time. This paper investigates the influence of measurement error on the Bayesian EWMA variability control chart, and it proposes two designs for the Bayesian EWMA variability control chart in the presence of measurement error. One is to modify the control limits based on the biased error-prone monitoring statistics, called the error-embedded control chart. The other is to design the control limits based on the error-corrected monitoring statistics, called the error-corrected control chart. Simulation results prove that both of the proposed control charts are reliable and have good detection performance in the presence of measurement error. Moreover, the average run lengths of the proposed control charts are exactly the same, indicating that both of them are equivalent control charts. Comparison results show that the existing control chart in Lin et al. is not in-control robust and fails to detect a downward shift in process variance when measurement error is present. Thus, using the error-embedded control chart or the error-corrected control chart to monitor processes with measurement errors is reliable and effective. Moreover, the proposed control charts, where π11 = 1 and π10 = 0, can be applied to monitor processes without measurement errors since their detection performance is equal to that of the existing control chart in Lin et al. Finally, we demonstrate the application of the error-embedded control chart and the error-corrected control chart to analyze the data from the service time system of a bank branch and the data from a semiconductor manufacturing process, showing that the proposed control charts can indeed be applied to data with measurement errors.