David Kahler

David Kahler

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2006 in Water Resources Research
Verified
Journal Article
Closed access
PDF file
DKDavid Kahler
David Kahler
WBWilfried Brutsaert
Wilfried Brutsaert

7 February 2018 in Water
Verified
Journal Article
Open access
PDF file
JEJoshua Edokpayi
Joshua Edokpayi
ERElizabeth T. Rogawski
Elizabeth T. Rogawski
DKDavid Kahler
David Kahler
CHCourtney Hill
Courtney Hill
CRCatherine Reynolds
Catherine Reynolds
RDRebecca Dillingham
Rebecca Dillingham
Consumption of microbial-contaminated water can result in diarrheal illnesses and enteropathy with the heaviest impact upon children below the age of five. We aimed to provide a comprehensive analysis of water quality in a low-resource setting in Limpopo province, South Africa. Surveys were conducted in 405 households in rural communities of Limpopo province to determine their water-use practices, perceptions of water quality, and household water-treatment methods. Drinking water samples were tested from households for microbiological contamination. Water from potential natural sources were tested for physicochemical and microbiological quality in the dry and wet seasons. Most households had their primary water source piped into their yard or used an intermittent public tap. Approximately one third of caregivers perceived that they could get sick from drinking water. All natural water sources tested positive for fecal contamination at some point during each season. The treated municipal supply never tested positive for fecal contamination; however, the treated system does not reach all residents in the valley; furthermore, frequent shutdowns of the treatment systems and intermittent distribution make the treated water unreliable. The increased water quantity in the wet season correlates with increased treated water from municipal taps and a decrease in the average contaminant levels in household water. This research suggests that wet season increases in water quantity result in more treated water in the region and that is reflected in residents’ water-use practices.

27 April 2016 in Water Resources Research
Verified
Journal Article
Open access
PDF file
DKDavid Kahler
David Kahler
Zbigniew J KabalaZbigniew J Kabala
Zbigniew J Kabala
One key limiting factor to groundwater remediation is contaminant sequestered in pores whose contents do not mix well with the bulk flow. Mixing between well‐connected (pores whose volume is flushed as water flows through the aquifer) and poorly connected pores (pores whose volume does not exchange readily when water flows through the aquifer) is of primary concern. Under steady flow, contaminants are effectively trapped in the poorly connected pores and are transferred only by molecular diffusion. This slow mixing process between pore types is a bottleneck to remediation. We present a novel rapidly pulsed pumping method that increases the mixing between these pore types. We do it in the context of pump‐and‐treat remediation because it is the most common remediation practice. In rapidly pulsed pumping, the increase in flow causes a deep sweep, which pushes the flow into poorly connected pores and sweeps out sequestered contaminants. The decrease in flow causes a vortex ejection, which causes the vortex within the poorly connected pore to emerge with contaminant. These actions are modeled with computational fluid mechanics to elucidate the individual mechanisms and determine how they function and interact. Cleanup of single and multiple poorly connected pore systems were simulated and show the acceleration possible. This technique can decrease the time and cost needed to remediate contaminated aquifers, which in the United States has been estimated to exceed $1 trillion. Since our rapidly pulsed pumping method enhances mixing between well‐connected and poorly connected pores, it can be applied to other remediation schemes such as in situ methods.

1 January 2019 in Journal of Environmental Engineering
Verified
Journal Article
Closed access
DKDavid Kahler
David Kahler
Zbigniew J KabalaZbigniew J Kabala
Zbigniew J Kabala
Groundwater contamination is expensive to remediate, primarily because of the treatment time required. Increased treatment time can be caused by several contributing factors, such as sequestration in low-permeability regions of an aquifer, which can cause tailing and rebound phenomena. One such region consists of dead-end pores. Once a contaminant enters the dead-end pores, it remains in an eddy and only moves back into well-connected pores, from which it can be advected away, by molecular diffusion. A previous study with computational fluid dynamics suggested that rapidly pulsed flow demonstrated the potential to accelerate contaminant removal from dead-end pores. Here, we tested the recovery of a dissolved contaminant under steady and rapidly pulsed flow from a porous media column with crushed glass, which should have naturally formed dead-end pores. This test simulated the fluid dynamics in a flow constrained by a column without sorption; therefore, this tested the dynamics in the dead-end pores but did not include the complete dynamics of a remediation scheme. The results showed accelerated removal under rapidly pulsed flow, which is consistent with results from the computational model; however, there may be additional or alternative sources of the sequestered contaminant.

5 January 2023 in Water
Verified
Journal Article
Open access
PDF file
MMMxolisi Blessing Mukhawana
Mxolisi Blessing Mukhawana
TKTOB KANYERERE
TOB KANYERERE
DKDavid Kahler
David Kahler
The devastating socioeconomic impacts of recent droughts have intensified the need for improved drought monitoring in South Africa (SA). This study has shown that not all indices can be universally applicable at all regions worldwide, and there is no single index that can represent all aspects of droughts. The aim of this study was to review the performance and applicability of the Palmer drought severity index (PDSI), surface water supply index (SWSI), vegetation condition index (VCI), standardised precipitation index (SPI), standardised precipitation evapotranspiration index (SPEI), standardised streamflow index (SSI), standardised groundwater index (SGI), and GRACE (Gravity Recovery and Climate Experiment)-based drought indices in SA and provide guidelines for selecting feasible candidates for integrated drought monitoring. The review is based on the ‘2016 World Meteorological Organisation (WMO) Handbook of Drought Indicators and Indices’ guidelines. The PDSI and SWSI are not feasible in SA, mainly because they are relatively complex to compute and interpret and cannot use readily available and accessible data. Combining the SPI, SPEI, VCI, SSI, and SGI using multi-index or hybrid methods is recommended. Hence, with best fitting probability distribution functions (PDFs) used, and with an informed choice between parametric and non-parametric approaches, this combination has the potential for integrated drought monitoring. Due to the scarcity of groundwater data, investigations on the use of GRACE-based groundwater drought indices must be carried out. These findings may contribute to improved drought early warning and monitoring in SA.

1 March 2020 in Journal of Environmental Engineering
Verified
Journal Article
Closed access
KJKathryn Nunnelley Jackson
Kathryn Nunnelley Jackson
DKDavid Kahler
David Kahler
IKIga Kucharska
Iga Kucharska
DRDavid Rekosh
David Rekosh
MHMarie-Louise Hammarskjold
Marie-Louise Hammarskjold
JSJames A. Smith
James A. Smith
This study investigates the inactivation of adenovirus by silver and copper in aqueous solution, compares silver and copper disinfection of adenovirus to the MS2 phage, and quantifies MS2 transport through porous ceramic filters fabricated with silver nitrate and copper nitrate added prior to firing the clay-sawdust-water mixture. The MS2 phage is commonly used as a model virus for testing the efficacy of point-of-use water treatment technologies. However, results show that MS2 phage is not a representative virus, specifically as a surrogate for silver ion inactivation of viruses. At safe drinking water concentrations, after 8 h of exposure, silver and copper resulted in a 0.91- and 1.61-log10 reduction of viable adenovirus, respectively. Under the same conditions, silver and copper resulted in a 0.42- and 1.46-log10 reduction of viable MS-2 phage, respectively. Transmission electron microscopy (TEM) images suggest the mechanism of adenovirus inactivation may be related to damage/removal of the viral fibers. Removal of MS2 phage by ceramic water filters is modest, 71.95% and 75.98% by silver- and copper-embedded filters, respectively. These results indicate that ionic silver is a better viral disinfectant than previously known based on data for the MS2 phage alone and that copper, both alone and in combination with silver, may further improve viral disinfection.