Shu Zhang

Dr. Shu Zhang

Electrical Engineering Department, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2023 in Protection and Control of Modern Power Systems
Verified
Journal Article
Open access
PDF file
DFDejin Fan
Dejin Fan
Shu ZhangShu Zhang
Shu Zhang
HHHe Huang
He Huang
LZLiping Zhou
Liping Zhou
YWYang Wang
Yang Wang
XXXianyong Xiao
Xianyong Xiao
Thermostatically controlled loads (TCLs) are regarded as having potential to participate in power grid regulation. This paper proposes a scheduling strategy with three-stage optimization for regional aggregators jointly participating in day-ahead scheduling to support demand response. The first stage is on the profit of aggregators and peak load of the grid. The line loss and voltage deviation of regulation are considered to ensure stable operation of the power grid at the second stage, which guarantees the fairness of the regulation and the comfort of users. A single temperature adjustment strategy is used to control TCLs to maximize the response potential in the third stage. Finally, digital simulation based on the IEEE 33-bus distribution network system proves that the proposed three-stage scheduling strategy can keep the voltage deviation within ± 5% in different situations. In addition, the Gini coefficient of distribution increases by 20% and the predicted percentage of dissatisfied is 48% lower than those without distribution.

11 April 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
SSSichen Shi
Sichen Shi
PWPeiyi Wang
Peiyi Wang
ZZZixuan Zheng
Zixuan Zheng
Shu ZhangShu Zhang
Shu Zhang
To satisfy the interests of multiple agents and those of comprehensive indicators such as peak-to-valley differences and load fluctuations occurring on the network side, this paper presents a flexible load demand-side response optimization method that considers the benefits of peak-to-valley smoothing. First, load aggregation modelling of air conditioning and electric vehicles was conducted, and the complementarity of the power consumption behavior of different types of flexible loads was used to improve the responsiveness of the load aggregator. Second, considering demand-side responses and taking into account the interests of both supply and demand, the load fluctuation and peak-to-valley difference on the network side are reduced, and a flexible load double-layer optimization model incorporating the peak-to-valley smoothing benefit is established. Finally, the effectiveness of the proposed optimization model is verified by using the KKT condition and the big M method to evaluate this two-layer optimization problem as a single-layer optimization problem. Comparative examples show that the proposed two-layer optimization method can take advantage of the complementarity of air conditioning and electric vehicles to improve the income of load aggregators. Moreover, the proposed method can effectively reduce the load peak-to-valley difference and load fluctuation of the distribution network by introducing the peak-to-valley smoothing benefit model.

1 June 2020 in IEEJ Transactions on Electrical and Electronic Engineering
Verified
Journal Article
Closed access
PDF file
Shu ZhangShu Zhang
Shu Zhang
XXXianyong Xiao
Xianyong Xiao
ZHZhengyou He
Zhengyou He

1 January 2024 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Closed access
YWYang Wang
Yang Wang
XZXiang Zhou
Xiang Zhou
JTJunmiao Tang
Junmiao Tang
XXXianyong Xiao
Xianyong Xiao
Shu ZhangShu Zhang
Shu Zhang
JSJiandong Si
Jiandong Si
The effects of nonlinear loads on voltage quality represent an emerging concern for islanded microgrids. Existing research works have mainly focused on harmonic power sharing among multiple inverters, which ignores the diversity of different inverters to mitigate harmonics from nonlinear loads. As a result, the voltage quality of microgrids cannot be effectively improved. To address this issue, this study proposes an adaptive harmonic virtual impedance (HVI) control for improving voltage quality of microgrids. Based on the premise that no inverter is overloaded, the main objective of the proposed control is to maximize harmonic power absorption by shaping the lowest output impedances of inverters. To achieve this, the proposed control is utilized to adjust the HVI of each inverter based on its operation conditions. In addition, the evaluation based on Monte Carlo harmonic power flow is designed to assess the performance of the proposed control in practice. Finally, comparative studies and control-in-the-loop experiments are conducted.

10 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
WZWenhai Zhang
Wenhai Zhang
RTRui Tang
Rui Tang
JWJunjian Wu
Junjian Wu
YCYiwei Chen
Yiwei Chen
CYChulan YANG
Chulan YANG
Shu ZhangShu Zhang
Shu Zhang
This paper proposes a novel AC side series arc fault (SAF) identification method based on Generalized Lissajous Trajectory (GLT) learning for low-voltage residential circuits. The method addresses challenges in detecting SAFs—characterized by high concealment, random occurrence, and limitations in existing protection devices—by leveraging the Hilbert transform to map current signals into 2D Generalized Lissajous Trajectories. These trajectories amplify key SAF features (e.g., zero-break distortion and random pulses). A ResNet50-based image recognition model achieves high-precision fault detection under specific load types, with a validation accuracy of up to 99.91% for linear loads and 98.93% for nonlinear loads. The algorithm operates within 1.6 ms, enabling real-time circuit breaker tripping. The proposed method achieves higher recognition accuracy with lower computational cost compared to other image-based methods. In this paper, an adjustable load signal modeling approach is proposed to visualize the current signal using GLT and complete the lightweight identification based on ResNet network, which provides new ideas and methods for series arc fault detection.

24 June 2026 in Energies
Verified
Journal Article
Open access
PDF file
JTJie Tang
Jie Tang
Shu ZhangShu Zhang
Shu Zhang
YZYuyin Zhao
Yuyin Zhao
Precise fault localization for high-speed railway continuous transmission lines is indispensable for sustaining power supply reliability and mitigating power outages. This study presents a novel fault localization approach that uses low-voltage information obtained from box-type substations distributed along continuous transmission lines. The proposed scheme relies on the distribution features of the positive-to-negative sequence voltage ratio (rPNV) measured at the low-voltage terminals of box-type substations. Results reveal that the magnitude of rPNV gradually declines from the main substation to the fault location in the fault upstream area, while it stays nearly unchanged in the downstream section. Based on this feature, the faulted section is initially determined by means of the nearest neighbor clustering method. Subsequently, the precise fault location is calculated by solving equations that combine the sequence voltage ratio at the fault point with the measurements obtained from the main substation and box-type substations downstream of the fault. The proposed method requires only asynchronous low-voltage measurements, eliminates the need for fault impedance modeling, and is applicable to various asymmetric faults. Simulation tests under different fault types, fault resistances (up to 2000 Ω), noise conditions, and neutral grounding modes demonstrate that the method achieves high accuracy and robustness.