Teruhiko Imamura

Dr. Teruhiko Imamura

University of Toyama
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2023 in Circulation
Verified
Journal Article
Closed access
PDF file
YHYasutomi Higashikuni
Yasutomi Higashikuni
WLWenhao Liu
Wenhao Liu
GNGenri Numata
Genri Numata
KTKimie Tanaka
Kimie Tanaka
DFDaiju Fukuda
Daiju Fukuda
MSMasataka Sata
Masataka Sata
Background: Mechanical stress on the heart, such as high blood pressure, initiates inflammation and causes hypertrophic heart disease. However, the regulatory mechanism of inflammation and its role in the stressed heart remain unclear. IL-1β (interleukin-1β) is a proinflammatory cytokine that causes cardiac hypertrophy and heart failure. Here, we show that neural signals activate the NLRP3 (nucleotide-binding domain, leucine-rich-containing family, pyrin domain-containing 3) inflammasome for IL-1β production to induce adaptive hypertrophy in the stressed heart. Methods: C57BL/6 mice, knockout mouse strains for NLRP3 and P2RX7 (P2X purinoceptor 7), and adrenergic neuron-specific knockout mice for SLC17A9, a secretory vesicle protein responsible for the storage and release of ATP, were used for analysis. Pressure overload was induced by transverse aortic constriction. Various animal models were used, including pharmacological treatment with apyrase, lipopolysaccharide, 2′(3′)- O -(4-benzoylbenzoyl)-ATP, MCC950, anti–IL-1β antibodies, clonidine, pseudoephedrine, isoproterenol, and bisoprolol, left stellate ganglionectomy, and ablation of cardiac afferent nerves with capsaicin. Cardiac function and morphology, gene expression, myocardial IL-1β and caspase-1 activity, and extracellular ATP level were assessed. In vitro experiments were performed using primary cardiomyocytes and fibroblasts from rat neonates and human microvascular endothelial cell line. Cell surface area and proliferation were assessed. Results: Genetic disruption of NLRP3 resulted in significant loss of IL-1β production, cardiac hypertrophy, and contractile function during pressure overload. A bone marrow transplantation experiment revealed an essential role of NLRP3 in cardiac nonimmune cells in myocardial IL-1β production and cardiac phenotype. Pharmacological depletion of extracellular ATP or genetic disruption of the P2X7 receptor suppressed myocardial NLRP3 inflammasome activity during pressure overload, indicating an important role of ATP/P2X7 axis in cardiac inflammation and hypertrophy. Extracellular ATP induced hypertrophic changes of cardiac cells in an NLRP3- and IL-1β–dependent manner in vitro. Manipulation of the sympathetic nervous system suggested sympathetic efferent nerves as the main source of extracellular ATP. Depletion of ATP release from sympathetic efferent nerves, ablation of cardiac afferent nerves, or a lipophilic β-blocker reduced cardiac extracellular ATP level, and inhibited NLRP3 inflammasome activation, IL-1β production, and adaptive cardiac hypertrophy during pressure overload. Conclusions: Cardiac inflammation and hypertrophy are regulated by heart-brain interaction. Controlling neural signals might be important for the treatment of hypertensive heart disease.

27 June 2020 in ESC Heart Failure
Verified
Journal Article
Open access
PDF file
TIToshihide Izumida
Toshihide Izumida
Teruhiko ImamuraTeruhiko Imamura
Teruhiko Imamura
MNMakiko Nakamura
Makiko Nakamura
NFNobuyuki Fukuda
Nobuyuki Fukuda
KKKoichiro Kinugawa
Koichiro Kinugawa
Aims Heart rate reduction therapy using ivabradine, a selective inhibitor of the funny current of the sinoatrial node, is widely used in the systolic heart failure cohort. However, the optimal target of heart rate remains controversial. The association between heart rate and ‘overlap’ between E‐wave and A‐wave in the pulse wave transmitral flow Doppler echocardiography might be a key to find the ideal heart rate in each individual. Methods and results We performed transthoracic echocardiography in patients with systolic heart failure, and the association between heart rate, deceleration time, and overlap length between E‐wave and A‐wave was assessed. In total, 368 patients with systolic heart failure (median 76 years old, 190 men, median ejection fraction 40%) were included. The measured overlap length was 35 (−72, 115) ms. Given the results of multiple linear regression analyses, we constructed a formula: estimated overlap length (ms) = −589 + 6.2 × heart rate (bpm) + 0.81 × deceleration time (ms), which had a good agreement with actually measured one (r = 0.62). The ideal heart rate, at which the overlap length is ‘zero’ and probably cardiac output is maximized, is calculated as follows: ideal heart rate (bpm) = 93 – 0.13 × deceleration time (ms). Conclusions We proposed a novel formula using deceleration time to estimate ideal heart rate that achieves a zero overlap between E‐wave and A‐wave in patients with systolic heart failure. Prognostic impact of the formula‐guided heart rate optimization should be studied.

1 March 2020 in Journal of Cardiology
Verified
Journal Article
Closed access
MNMakiko Nakamura
Makiko Nakamura
Teruhiko ImamuraTeruhiko Imamura
Teruhiko Imamura
HUHiroshi Ueno
Hiroshi Ueno
KKKoichiro Kinugawa
Koichiro Kinugawa

23 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Teruhiko ImamuraTeruhiko Imamura
Teruhiko Imamura
MHMasakazu Hori
Masakazu Hori
YUYohei Ueno
Yohei Ueno
NNNikhil Narang
Nikhil Narang
HOHiroshi Onoda
Hiroshi Onoda
KKKoichiro Kinugawa
Koichiro Kinugawa
Background: Remote dielectric sensing (ReDS™) is an electromagnetic-based technology used to noninvasively measure lung fluid levels. The association between ReDS values and invasively measured hemodynamics, particularly among those with small physics, remains unknown. Methods: Consecutive patients with chronic heart failure who were admitted to our institute and underwent invasive right heart catheterization as well as simultaneous ReDS measurement at clinically stable conditions between September and November 2021 were prospectively included. The colinearity between ReDS values and pulmonary capillary wedge pressure was studied. Results: In total, 30 patients (median 79 (73, 84) years old, 13 men) were included. Median ReDS value was 26% (22%, 28%). ReDS values had a moderate collinearity with pulmonary capillary wedge pressure (r = 0.698, p < 0.001), even among those with a body height < 155 cm. ReDS values with a cutoff of 28% predicted a pulmonary capillary wedge pressure > 15 mmHg with sensitivity 0.70 and specificity 0.75. Conclusions: An electromagnetic-based engineering ReDS might be a potential tool to estimate cardiac pressure in patients with heart failure, including those with small physics.

29 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Teruhiko ImamuraTeruhiko Imamura
Teruhiko Imamura
WGWataru Gonoi
Wataru Gonoi
MHMasakazu Hori
Masakazu Hori
YUYohei Ueno
Yohei Ueno
NNNikhil Narang
Nikhil Narang
KKKoichiro Kinugawa
Koichiro Kinugawa
Background: The accuracy of the remote dielectric sensing (ReDSTM) system, which is a noninvasive electromagnetic-based technology to quantify lung fluid levels, particularly among those with small body size, remains uncertain. Methods: Hospitalized patients with and without heart failure underwent assessment of lung fluid levels with ReDS and successive chest computed tomography imaging. We performed a correlation analysis of the ReDS measurement, representing lung fluid levels, and computed tomography-derived high attenuation area percentage, which also provides a spatial quantification of lung fluid level. Results: A total of 46 patients (median 76 years old, 28 men), including 28 patients with heart failure, were included. The median ReDS value was 28% (interquartile: 23%, 33%), and the median percentage of high attenuation area was 21.6% (14.4%, 28.5%). ReDS values and percentage of high attenuation area were moderately correlated (r = 0.65, p < 0.001), irrespective of the existence of heart failure. ReDS value independently predicted the percentage of high attenuation area seen on computed tomography (p < 0.001). Conclusions: The ReDS system may be a promising, noninvasive tool to quantify fluid lung levels, as validated by comparison with chest computed tomography imaging. Further studies are warranted to validate the utility and applicability of this technology to a variety of clinical scenarios.

1 October 2020 in Journal of Cardiac Failure
Verified
Journal Article
Closed access
Teruhiko ImamuraTeruhiko Imamura
Teruhiko Imamura
NNNikhil Narang
Nikhil Narang
GKGene Kim
Gene Kim
DNDaisuke Nitta
Daisuke Nitta
TFTakeo Fujino
Takeo Fujino
NUNir Uriel
Nir Uriel