Rajendra Kumar Ramasamy Thangavelu

Dr. Rajendra Kumar Ramasamy Thangavelu

Department of Nanoscience and Technology, Advanced Materials and Devices Laboratory (AMDL), Bharathiar University, Coimbatore 641046, Tamil Nadu, India

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2018 in ACS Sensors
Verified
Journal Article
Closed access
DMDebasis Maity
Debasis Maity
RTRajendra Kumar Ramasamy Thangavelu
Rajendra Kumar Ramasamy Thangavelu

12 April 2018 in ACS Omega
Verified
Journal Article
Open access
CMCherukutty Ramakrishnan Minitha
Cherukutty Ramakrishnan Minitha
VAVelunair Sukumaran Anithaa
Velunair Sukumaran Anithaa
VSVijayakumar Subramaniam
Vijayakumar Subramaniam
RTRajendra Kumar Ramasamy Thangavelu
Rajendra Kumar Ramasamy Thangavelu
The chemically reduced graphene oxide (rGO) was prepared by the reduction of graphene oxide by hydrazine hydrate. By varying the reduction time (10 min, 1 h, and 15 h), oxygen functional groups on rGO were tremendously controlled and they were named RG1, RG2, and RG3, respectively. Here, we investigate the impact of oxygen functional groups on the detection of ammonia and toluene at room temperature. Their effect on sensing mechanism was analyzed by first-principles calculation-based density functional theory. The sensing material was fabricated, and the effect of reduction time shown improved the recovery of ammonia and toluene sensing at room temperature. Structural, morphological, and electrical characterizations were performed on both RG1 and RG3. The sensor response toward toluene vapor of 300 ppm was found to vary 4.4, 2.5, and 3.8% for RG1, RG2, and RG3, respectively. Though RG1 shows higher sensing response with poor recovery, RG3 exhibited complete desorption of toluene after the sensing process with response and recovery times of approximately 40 and 75 s, respectively. The complete recovery of toluene molecules on RG3 is due to the generation of new sites after the reduction of oxygen functionalities on its surface. It could be suggested that these sites provided anchor to ammonia and toluene molecules and good recovery under N2 purge. Both theoretical and experimental studies revealed that tuning the oxygen functional groups on rGO could play a vital role in the detection of volatile organic compounds (VOCs) on rGO sheets and was discussed in detail. This study could provoke knowledge about rGO-based sensor dependency with oxygen functional groups and shed light on effective monitoring of VOCs under ambient conditions for air quality monitoring applications.


14 May 2018 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Closed access
KRKugalur Shanmugam Ranjith
Kugalur Shanmugam Ranjith
Chung-Li DongChung-Li Dong
Chung-Li Dong
YLYing-Rui Lu
Ying-Rui Lu
YHYu-Cheng Huang
Yu-Cheng Huang
CCChi-Liang Chen
Chi-Liang Chen
RTRajendra Kumar Ramasamy Thangavelu
Rajendra Kumar Ramasamy Thangavelu

10 July 2019 in ACS Omega
Verified
Journal Article
Open access
DKDharman Ranjith Kumar
Dharman Ranjith Kumar
KRKugalur Shanmugam Ranjith
Kugalur Shanmugam Ranjith
YHYuvaraj Haldorai
Yuvaraj Haldorai
AKAsokan Kandasami
Asokan Kandasami
RTRajendra Kumar Ramasamy Thangavelu
Rajendra Kumar Ramasamy Thangavelu
The present study focuses on the effects of nitrogen (N) ion implantation in vertically aligned ZnO nanorod arrays (NRAs) and the photocatalytic degradation of acetaminophen. The X-ray diffraction of these NRAs exhibit a wurtzite structure with a predominant (002) diffraction peak that shifts slightly after N-ion implantation. The field emission scanning electron microscopic images of as-prepared NRAs show a length of ∼4 μm and diameter of ∼150 nm. UV–visible spectroscopy reveals that the band gap of pristine ZnO NRAs decreases from 3.2 to 2.18 eV after N-ion implantation. Under visible irradiation, the N-ion-implanted ZnO catalyst exhibits significant enhancement of the photocatalytic degradation of acetaminophen from 60.0 to 98.46% for 120 min.

31 December 2013 in Langmuir
Verified
Journal Article
Closed access
KRKrishnamoorthy Rajavel
Krishnamoorthy Rajavel
RGRajkumar Gomathi
Rajkumar Gomathi
SMSellamuthu Manian
Sellamuthu Manian
RTRajendra Kumar Ramasamy Thangavelu
Rajendra Kumar Ramasamy Thangavelu