View All Publications
9 July 2020 in Fire
Verified
Journal Article
Open access
PDF file
Dan ThompsonDan Thompson
Dan Thompson
DSDave Schroeder
Dave Schroeder
SWSophie Wilkinson
Sophie Wilkinson
QBQuinn Barber
Quinn Barber
GBGreg Baxter
Greg Baxter
JZJessica Zerb
Jessica Zerb
A 3.6 ha experimental fire was conducted in a black spruce peatland forest that had undergone thinning the year prior. After 50 m of spread in a natural stand at 35–60 m min−1, the crown fire (43,000 kW m−1 intensity using Byram’s method) encountered the 50% stem removal treatment; spread rates in the treatment were 50–60 m min−1. Fuel consumption in the control (2.75 kg m−2) was comparable to the treatment (2.35 kg m−2). Proxy measurements of fire intensity using in-stand heat flux sensors as well as photogrammetric flame heights had detected intensity reductions to 30–40% of the control. Crown fuel load reductions (compensated by higher surface fuel load) appear to be the most significant contributor to the decline in intensity, despite drier surface fuels in the treatment. The burn depth of 5 cm in moss and organic soil did not differ between control and treatment. These observations point to the limited effectiveness (likely reductions in crown fire intensity but not spread rate) of stem removal in boreal black spruce fuel types with high stem density, low crown base height and high surface fuel load. The observed fire behaviour impacts differ from drier conifer forests across North America.

2 February 2022 in Fire Technology
Verified
Journal Article
Open access
PDF file
Dan ThompsonDan Thompson
Dan Thompson
DYDaniel A. Yip
Daniel A. Yip
EKEunmo Koo
Eunmo Koo
RLRodman Linn
Rodman Linn
GMGinny Marshall
Ginny Marshall
DSDave Schroeder
Dave Schroeder
Firebrand travel and ignition of spot fires is a major concern in the Wildland-Urban Interface and in wildfire operations overall. Firebrands allow for the efficient breaching across fuel-free barriers such as roads, rivers and constructed fuel breaks. Existing observation-based knowledge on medium-distance firebrand travel is often based on single tree experiments that do not replicate the intensity and convective updraft of a continuous crown fire. Recent advances in acoustic analysis, specifically pattern detection, has enabled the quantification of the rate at which firebrands are observed in the audio recordings of in-fire cameras housed within fire-proof steel boxes that have been deployed on experimental fires. The audio pattern being detected is the sound created by a flying firebrand hitting the steel box of the camera. This technique allows for the number of firebrands per second to be quantified and can be related to the fire's location at that same time interval (using a detailed rate of spread reconstruction) in order to determine the firebrand travel distance. A proof of concept is given for an experimental crown fire that shows the viability of this technique. When related to the fire's location, key areas of medium-distance spotting are observed that correspond to regions of peak fire intensity. Trends on the number of firebrands landing per square metre as the fire approaches are readily quantified using low-cost instrumentation.