Yi-Jung Tsai

Dr. Yi-Jung Tsai


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
YCYung-Chuan Chen
Yung-Chuan Chen
YTYi-Jung Tsai
Yi-Jung Tsai
HHHao-Yuan Hsiao
Hao-Yuan Hsiao
YCYen-Wei Chiu
Yen-Wei Chiu
YTYuan-Kun Tu
Yuan-Kun Tu
Chih-Kun HsiaoChih-Kun Hsiao
Chih-Kun Hsiao
Bone drilling is a common procedure used to create pilot holes for inserting screws to secure implants for fracture fixation. However, this process can increase bone temperature and the excessive heat can lead to cell death and thermal osteonecrosis, potentially causing early fixation failure or complications. We applied a three-dimensional dynamic elastoplastic finite element model to evaluate the propagation and distribution of heat during bone drilling and assess the thermally affected zone (TAZ) that may lead to thermal necrosis. This model investigates the parameters influencing bone temperature during bone drilling, including drill diameter, rotational speed, feed force, and predrilled hole. The results indicate that our FE model is sufficiently accurate in predicting the temperature rise effect during bone drilling. The maximum temperature decreases exponentially with radial distance. When the feed forces are 40 and 60 N, the maximum temperature does not exceed 45 °C. However, with feed forces of 10 and 20 N, both the maximum temperatures exceed 45 °C within a radial distance of 0.2 mm, indicating a high-risk zone for potential thermal osteonecrosis. With the two-stage drilling procedure, where a 2.5 mm pilot hole is predrilled, the maximum temperature can be reduced by 14 °C. This suggests that higher feed force and rotational speed and/or using a two-stage drilling process could mitigate bone temperature elevation and reduce the risk of thermal osteonecrosis during bone drilling.

ICI-Fang Cheng
I-Fang Cheng
LKLi-Chieh Kuo
Li-Chieh Kuo
YTYi-Jung Tsai
Yi-Jung Tsai
FSFong-Chin Su
Fong-Chin Su
We compared the physical function performances of community-dwelling and day care center older adults with and without regular physical activity (PA). A total of 163 Taiwanese older adults living in rural communities participated. PA habits and physical functional performances were assessed. The participants were divided into community-dwelling (CD) and senior day care (DC) center groups that were further classified into regular physical activity (RPA) and non-physical activity (NPA) subgroups. Comparison took place between subgroups. In the CD group, only the grip strength, pinch strength, and box and blocks test scored significantly better for the participants with regular PA. Muscle strength, flexibility, and three items of functional ability of participants with regular PA were significantly better in the DC group. An active lifestyle contributes to a good old-age life. The effective amount of PA and the reduction of sedentary time should be advocated to prevent frailty and disability in older adults.

YTYi-Jung Tsai
Yi-Jung Tsai
YTYuan-Kun Tu
Yuan-Kun Tu
FSFong-Chin Su
Fong-Chin Su
YTYuan-Kun Tu
Yuan-Kun Tu
Surgical reconstruction and postoperative rehabilitation are both important for restoring function in patients with traumatic brachial plexus injuries (BPIs). The current study aimed to understand variations in recovery progression among patients with different injury levels after receiving the nerve transfer methods. A total of 26 patients with BPIs participated in a rehabilitation training program over 6 months after nerve reconstruction. The differences between the first and second evaluations and between C5–C6 and C5–C7 BPIs were compared. Results showed significant improvements in elbow flexion range (p = 0.001), British Medical Research Council’s score of shoulder flexion (p = 0.046), shoulder abduction (p = 0.013), shoulder external rotation (p = 0.020), quantitative muscle strength, and grip strength at the second evaluation for both groups. C5–C6 BPIs patients showed a larger shoulder flexion range (p = 0.022) and greater strength of the shoulder rotator (p = 0.004), elbow flexor (p = 0.028), elbow extensor (p = 0.041), wrist extensor (p = 0.001), and grip force (p = 0.045) than C5–C7 BPIs patients at the second evaluation. Our results indicated different improvements among patients according to injury levels, with quantitative values assisting in establishing goals for interventions.

5 September 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Chih-Kun HsiaoChih-Kun Hsiao
Chih-Kun Hsiao
HHHao-Yuan Hsiao
Hao-Yuan Hsiao
YTYi-Jung Tsai
Yi-Jung Tsai
CHChao-Ming Hsu
Chao-Ming Hsu
YTYuan-Kun Tu
Yuan-Kun Tu
Spinal fusion surgery leads to the restriction of mobility in the vertebral segments postoperatively, thereby causing stress to rise at the adjacent levels, resulting in early degeneration and a high risk of adjacent vertebral fractures. Thus, to address this issue, non-fusion surgery applies some pedicle screw-based dynamic stabilisation systems to provide stability and micromotion, thereby reducing stress in the fusion segments. Among these systems, the hybrid performance stabilisation system (HPSS) combines a rigid rod, transfer screw, and coupler design to offer a semi-rigid fixation method that preserves some mobility near the fusion site and reduces the adjacent segment compensatory effects. However, further research and confirmation are needed regarding the biomechanical effects of the dynamic coupler stiffness of the HPSS on the intrinsic degenerated adjacent segment. Therefore, this study utilised the finite element method to investigate the impact of the coupler stiffness of the HPSS on the mobility of the lumbar vertebral segments and the stress distribution in the intervertebral discs under flexion, extension, and lateral bending, as well as the clinical applicability of the HPSS on the discs with intrinsic moderate and severe degeneration at the adjacent level. The analytical results indicated that, regardless of the degree of disc degeneration, the use of a dynamic coupler stiffness of 57 N/mm in the HPSS may reduce the stress concentrations at the adjacent levels. However, for severely degenerated discs, the postoperative stress on the adjacent segments with the HPSS was still higher compared with that of the discs with moderate degeneration. We conclude that, when the discs had moderate degeneration, increasing the coupler stiffness led to a decrease in disc mobility. In the case of severe disc degeneration, the effect on disc mobility by coupler stiffness was less pronounced. Increasing the coupler stiffness ked to higher stress on intervertebral discs with moderate degeneration, while its effect on stress was less pronounced for discs with severe degeneration. It is recommended that patients with severe degeneration who undergo spinal dynamic stabilisation should remain mindful of the risk of accelerated adjacent segment degeneration.

6 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
YCYung-Chuan Chen
Yung-Chuan Chen
YTYi-Jung Tsai
Yi-Jung Tsai
HHHao-Yuan Hsiao
Hao-Yuan Hsiao
YCYen-Wei Chiu
Yen-Wei Chiu
YTYuan-Kun Tu
Yuan-Kun Tu
Chih-Kun HsiaoChih-Kun Hsiao
Chih-Kun Hsiao
Bone drilling is a common procedure used to create pilot holes for inserting screws to secure implants for fracture fixation. However, dis process can increase bone temperature, teh excessive heat can lead to cell death and thermal osteonecrosis, potentially causing early fixation failure or complications. We conducted a three-dimensional dynamic elastoplastic finite element model to evaluate teh propagation and distribution of heat during bone drilling and assess teh thermally TEMPeffected zone (TAZ) dat may lead to thermal necrosis. dis model investigates teh parameters influencing bone temperature during bone drilling, including drill diameter, rotational speed, feed force, and predrilled hole. Teh results indicate dat our FE model is sufficiently accurate in predicting teh temperature rise TEMPeffect during bone drilling. Teh maximum temperature decreases exponentially wif radial distance. When teh feed forces are 40 and 60 N, teh maximum temperature does not exceed 45 °C. However, wif feed forces of 10 and 20 N, both teh maximum temperature exceeds 45 °C wifin a radial distance of 0.2 mm, indicating a high-risk zone for potential thermal osteonecrosis. Wif teh two-stage drilling procedure, where a 2.5 mm pilot hole is pre-drilled, teh maximum temperature can be reduced by 14 °C. dis suggests dat higher feed force and rotational speed and/or using a two-stage drilling process could mitigate bone temperature elevation and reduce teh risk of thermal osteonecrosis during bone drilling.

24 October 2023 in Life
Verified
Journal Article
Open access
PDF file
Chih-Kun HsiaoChih-Kun Hsiao
Chih-Kun Hsiao
YCYen-Wei Chiu
Yen-Wei Chiu
HHHao-Yuan Hsiao
Hao-Yuan Hsiao
YTYi-Jung Tsai
Yi-Jung Tsai
CLCheng-Hung Lee
Cheng-Hung Lee
YTYuan-Kun Tu
Yuan-Kun Tu
The locking plate may provide improved fixation in osteoporotic bone; however, it has been reported to fail due to varus collapse or screw perforation of the articular surface, especially in osteoporotic bone with medial cortex comminution. Using bone graft as an intramedullary strut together with plate fixation may result in a stronger construct. However, the drawbacks of bone grafts include limited supply, high cost, and infection risk. PMMA (so-called bone cement) has been widely used for implant fixation due to its good mechanical properties, fabricability, and biocompatibility. The risk of donor-site infection and the drawbacks of allografting may be overcome by considering PMMA struts as alternatives to fibular grafts for humeral intramedullary grafting surgeries. However, the potential effects of intramedullary PMMA strut on the dynamic behaviour of osteoporotic humerus fractures remain unclear. This study aimed to investigate the influence of an intramedullary PMMA strut on the stability of unstable proximal humeral fractures in an osteoporotic synthetic model. Two fixation techniques, a locking plate alone (non-strut group) and the same fixation augmented with an intramedullary PMMA strut (with-strut group), were cyclically tested in 20 artificial humeral models. Axially cyclic testing was performed to 450 N for 10,000 cycles, intercyclic motion, cumulated fragment migration, and residual deformation of the constructs were determined at periodic cyclic intervals, and the groups were compared. Results showed that adding an intramedullary PMMA strut could decrease 1.6 times intercyclic motion, 2 times cumulated fracture gap migration, and 1.8 times residual deformation from non-strut fixation. During cycling, neither screw pull-out, cut-through, nor implant failure was observed in the strut-augmented group. We concluded that the plate-strut mechanism could enhance the cyclic stability of the fixation and minimize the residual displacement of the fragment in treating osteoporotic proximal humeral unstable fractures. The PMMA strut has the potential to substitute donor bone and serve as an intramedullary support when used in combination with locking plate fixation. The intramedullary support with bone cement can be considered a solution in the treatment of osteoporotic proximal humeral fractures, especially when there is medial comminution.