Manfeng Gong

Prof. Dr. Manfeng Gong


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
XCxiaojun chen
xiaojun chen
DLDejin Li
Dejin Li
DMDeyun Mo
Deyun Mo
ZCZaifu Cui
Zaifu Cui
XLXin Li
Xin Li
MGManfeng Gong
Manfeng Gong
The extensive water pollution caused by production activities is a key issue that needs to be addressed in the aquaculture industry. The dynamic monitoring of water quality is essential for understanding water quality and the growth of fish fry. Here, a low-cost, low-noise, real-time monitoring and automatic feedback biomimetic robotic fish was proposed for the dynamic monitoring of multiple water quality parameters in aquaculture. The biomimetic robotic fish achieved a faster swimming speed and more stable posture control at a swing angular velocity of 16 rad/s by using simulation analysis. A fast swimming speed (0.4 m/s) was achieved through the control of double-jointed pectoral and caudal fins, exhibiting various types of movements, such as straight swimming, obstacle avoidance, turning, diving, and surfacing. As a demonstration of application, bionic robotic fish were placed in a lake for on-site water sampling and parameter detection. The relative average deviations in water quality parameters, such as water temperature, acidity and alkalinity, and turbidity, were 1.25%, 0.07%, and 0.94%, respectively, meeting the accuracy requirements for water quality parameter detection. In the future, bionic robotic fish are beneficial for monitoring water quality, fish populations, and behaviors, improving the efficiency and productivity of aquaculture, and also providing interesting tools and technologies for science education and ocean exploration.

6 March 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
XCxiaojun chen
xiaojun chen
DMDeyun Mo
Deyun Mo
MGManfeng Gong
Manfeng Gong
Water pollution seriously affects human health. Accurate and rapid detection and timely treatment of toxic substances in water are urgently needed. A stacked multilayer electrostatic printing technique was developed for making nanofiber-based microfluidic chips for water-quality testing. Nanofiber membrane matrix structures for microfluidic devices were fabricated by electrospinning. A hydrophobic barrier was then printed through electrostatic wax printing. This process was repeatedly performed to create three-dimensional nanofiber-based microfluidic analysis devices (3D-µNMADs). Flexible printing enabled one-step fabrication without the need for additional alignment or adhesive bonding. Practical applications of 3D-µNMADs include a colorimetric platform to quantitatively detect iron ion concentrations in water. There is also great potential for personalized point-of-care testing. Overall, the devices offer simple fabrication processes, flexible prototyping, potential for mass production, and multi-material integration.

1 January 2021 in Filomat
Verified
Journal Article
Open access
PDF file
KKKuang Yuan Kung
Kuang Yuan Kung
MGManfeng Gong
Manfeng Gong
Hari Mohan SrivastavaHari Mohan Srivastava
Hari Mohan Srivastava
SLShy-Der Lin
Shy-Der Lin
The principles of superposition and separation of variables are used here in order to investigate the analytical solutions of a certain transient heat conduction equation. The structure of the transient temperature appropriations and the heat-transfer distributions are summed up for a straight mix of the results by means of the Fourier-Bessel arrangement of the exponential type for the investigated partial differential equation.

19 May 2022 in Advances in Applied Ceramics: Structural, Functional and Bioceramics
Verified
Journal Article
Closed access
MLMeng Li
Meng Li
ZCZanlin Cheng
Zanlin Cheng
JDJán Dusza
Ján Dusza
ZSZhuolin Song
Zhuolin Song
FXFangkun Xiao
Fangkun Xiao
CZChengyu Zhang
Chengyu Zhang
The wear behaviour of WC-Co cemented carbide reinforced with graphene platelets (WC-Co-GPLs composite) was investigated. The tribological parameters as friction coefficient and wear rate were measured using a ball-on-plate configuration with different contact loads. The microstructures and worn surfaces of composites were studied. The WC-Co-GPLs composite exhibits significantly better tribological properties in comparison to the WC-Co which is most evident at contact load of 80 N, where the friction coefficient and wear rate of the WC-Co-GPLs composite are 0.339 and 9.27 × 10−6 mm3·(m·N)−1, respectively. The improvement in wear behaviour of WC-Co-GPLs composite is attributed to the formation of the tribofilm during the wear test and enhancement of mechanical properties of the WC-Co-GPLs composite. The pulled-out GPLs attaches on the worn surface contribute to the formation of tribofilms during tribology test, especially at higher loads. The tribofilms protect the WC-Co-GPLs from wear and guarantee the integrity of the worn surface.

1 May 2022 in Strength of Materials
Verified
Journal Article
Closed access
PDF file
GSG. Z. Sui
G. Z. Sui
MGManfeng Gong
Manfeng Gong
XWX. H. Wang
X. H. Wang
XXX. Q. Xia
X. Q. Xia
DMD. Y. Mo
D. Y. Mo
JDJ. Dusza
J. Dusza