Harvard Medical School – Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA 02114, USA
+1
Dr. Giorgio Bonmassar
Harvard Medical School – Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA 02114, USA
Fluid dynamics during sleep: During non–rapid eye movement sleep, low-frequency oscillations in neural activity support memory consolidation and neuronal computation. Sleep is also associated with increased interstitial fluid volume and clearance of metabolic waste products. It is unknown why these processes co-occur and how they are related. Fultz et al. simultaneously measured electrophysiological, hemodynamic, and flow signals in the human brain (see the Perspective by Grubb and Lauritzen). Large oscillations of fluid inflow to the brain appeared during sleep and were tightly coupled to functional magnetic resonance imaging signals and entrained to electroencephalogram slow waves. Slow oscillatory neuronal activity thus leads to oscillations in blood volume, drawing cerebrospinal fluid into and out of the brain. Science , this issue p. 628 ; see also p. 572
Clinical electrical stimulation systems — such as pacemakers and deep brain stimulators (DBS) — are an increasingly common therapeutic option to treat a large range of medical conditions. Despite their remarkable success, one of the significant limitations of these medical devices is the limited compatibility with magnetic resonance imaging (MRI), a standard diagnostic tool in medicine. During an MRI exam, the leads used with these devices, implanted in the body of the patient, act as an electric antenna potentially causing a large amount of energy to be absorbed in the tissue, which can lead to serious heat-related injury. This study presents a novel lead design that reduces the antenna effect and allows for decreased tissue heating during MRI. The optimal parameters of the wire design were determined by a combination of computational modeling and experimental measurements. The results of these simulations were used to build a prototype, which was tested in a gel phantom during an MRI scan. Measurement results showed a three-fold decrease in heating when compared to a commercially available DBS lead. Accordingly, the proposed design may allow a significantly increased number of patients with medical implants to have safe access to the diagnostic benefits of MRI.