Due to the rise in global temperature and climate change, the detection of CO2, SO2 and NO pollutants is important in smart cities. In this paper, an H-shaped photoacoustic cell is utilized for the detection of low-concentration gases. The geometry of the cell is miniaturized and designed with specific parameters in order to increase its efficiency and performance. The designed cell eliminates problems such as bulkiness and cost, which prevent the use of sensors in detecting greenhouse gases. The simplicity of the design expands the application rate of the cell in practice. In order to consider the viscosity and thermal effects, the cell is formulized by fully linearized Navier–Stokes equations, and various parameters, such as acoustic pressure, frequency response, sound speed (sound velocity) and quality factor, are investigated for the mentioned gases. The performance of the system is frequency-based, and the target gases can be detected by using a microelectromechanical resonator as a pressure sensor. Quality factor analysis expresses that CO2, SO2 and NO gases have quality factors of 27.84, 33.62 and 33.32, respectively. The performance of the cell in the resonance state can be expressed by the linear correlation between the results. The background noise generated in the photoacoustic research has been removed by miniaturization due to the obtained resonance, and the proposed cell provides a proper signal-to-noise ratio. The results of the proposed system represent the increase in the quality factor, which reduces the losses and thus increases the sensitivity of the system in the study of greenhouse gases.
In photoacoustic spectroscopy, the signal is inversely proportional to the resonant cell volume. Photoacoustic spectroscopy (PAS) is an absorption spectroscopy technique that is suitable for detecting gases at low concentrations. This desirable feature has created a growing interest in miniaturizing PA cells in recent years. In this paper, a simulation of a miniaturized H-type photoacoustic cell consisting of two buffer holes and a resonator was performed in order to detect CO, NH3, NO, and CH4 pollutants. These gases are the main components of the air pollutants that are produced by the automotive industry. The linear forms of the continuity, Navier–Stokes equations, and the energy equation were solved using the finite element method in a gaseous medium. The generated pressure could be measured by a MEMS sensor. Photoacoustic spectroscopy has proven to be a sensitive method for detecting pollutant gases. The objectives of the measurements were: determining the proper position of the pressure gauge sensor; measuring the frequency response; measuring the frequency response changes at different temperatures; studying the local velocity at the resonant frequency; and calculating the quality factor. The acoustic quality coefficient, acoustic response (pressure), local velocity, frequency response, and the effect of different temperatures on the frequency response were investigated. A frequency response measurement represents the fact that different gases have different resonance frequencies, for which CO and NO gases had values of 23.131 kHz and 23.329 kHz, respectively. The difference between these gases was 200 Hz. NH3 and CH4 gases with values of 21.206 kHz and 21.106 kHz were separable with a difference of 100 Hz. In addition, CO and NO gases had a difference of 2000 Hz compared to NH3 and CH4, which indicates the characteristic fingerprint of the designed cell in the detection of different gases. Better access to high-frequency acoustic signals was the goal of the presented model in this paper.
7 January 2019 in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
Purpose: Digital microfluidic devices have been demonstrated to have great potential for a wide range of applications. These devices need expensive photolithography process and clean room facilities, while printed circuit board (PCB) technology provides high configurability and at low cost. This study aims to investigate the mechanism of electrowetting-on-a-dielectric (EWOD) on PCB by solving the multiphysics interaction between fluid droplet and electric field. The performance of system will be improved by inducing an efficient electric field inside the droplet. Design/methodology/approach: To induce an electric field inside the droplet on a PCB and change the initial contact angle, the mechanism of EWOD is studied based on energy minimization method and a set of simulations are carried out by considering multiphysics interaction between the fluid droplet and external electric field. The performance of EWOD on a PCB system is investigated using different electrode structures. Findings: Surface tension plays an efficient role in smaller sizes and can be used to move and control a fluid droplet on a surface by changing the interfacial surface tension. EWOD on a PCB system is studied. and it revealed that any change in electric field affects the droplet contact angle and as a result droplet deformation and movement. The electrode pattern is an important parameter which could change the electric potential distribution inside the droplet. Array of electrodes with square, zigzag interdigitated and crescent shapes are studied to enhance the EWOD force on a PCB substrate. Based on the results, the radial shape of the crescent electrodes keeps almost the same actuated contact line, applies uniform force on the droplet periphery and prevents the droplet from large deformation. A droplet velocity of 0.6 mm/s is achieved by exciting the crescent electrodes at 315 V. Furthermore, the behavior of system is characterized for process parameters such as actuation voltage, dielectric constant of insulator layer, fluidic material properties and the resultant velocity and contact angle. The study of contact angle distribution and droplet motion revealed that it is helpful to generate EWOD mechanism on a PCB which does not need more complicated fabrication processes. Originality/value: The ability to handle and manipulate the droplets is very important for chemistry on-chip analysis such as immunoassay chips. Furthermore, a PCB-based electrowetting-on-dielectric device is of high interest because it does not need cleanroom facilities and avoids additional high-cost fabrication processes. In the present research, the EWOD mechanism is studied on a PCB by using different electrode patterns.
Cancers are diseases described by the irregular spread of cells that have developed invasive features, enabling them to invade adjacent tissues. The specific diagnosis and effective management of oncological treatments depend on the timely detection of circulating tumor cells (CTCs) in a patient’s bloodstream. One of the most promising approaches to CTC separation from blood fractions involves the dielectrophoresis (DEP) technique. This research presents a new DEP-based bionic system designed for MDA-MB-231 breast cancer cell isolation from white blood cell (WBC) subtypes with a viable approach to cell viability. This work leverages the principle that every cell type possesses a unique dielectric fingerprint. This dielectrophoresis microfluidic device is designed to act as a scanner, reading these fingerprints to achieve a continuous, label-free separation of cancer cells from blood components with a high efficiency. In the proposed system that consists of three different stages, the first stage allows for separating B-lymphocytes and Monocytes from Granulocytes and MDA-MB-231 cells. The separation of B-lymphocytes from Monocytes occurs in the second step, while the last step concerns the separation of Granulocytes and MDA-MB-231 cells. In the analysis, x-y graphs of the electric potentials, velocity fields, pressure distributions, and cellular DEP forces applied to the cells, as well as the resulting particle paths, are provided. The model predicts that the system operates with a separation efficiency of nearly 92%. This work focuses on an investigation of the impact of electrode potentials, the velocity of cells, the number of electrodes, the width of the channel, and the output angles on enhancing the separation efficiency of particles.