Kathryn Beardsall

Dr. Kathryn Beardsall


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2010 in The Journal of Pediatrics
Verified
Journal Article
Closed access
KBKathryn Beardsall
Kathryn Beardsall
SVSophie Vanhaesebrouck
Sophie Vanhaesebrouck
AOAmanda L. Ogilvy-Stuart
Amanda L. Ogilvy-Stuart
CVChristine Vanhole
Christine Vanhole
CPChris R. Palmer
Chris R. Palmer
DDDavid Dunger
David Dunger

1 May 2010 in Early Human Development
Verified
Journal Article
Closed access
KBKathryn Beardsall
Kathryn Beardsall

21 June 2005 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Open access
PDF file
KBKathryn Beardsall
Kathryn Beardsall
AOA L Ogilvy-Stuart
A L Ogilvy-Stuart
JAJ Ahluwalia
J Ahluwalia
MTM Thompson
M Thompson
DDDavid Dunger
David Dunger
Objective: To determine the feasibility of continuous glucose monitoring in the very low birthweight baby requiring intensive care, as these infants are known to be at high risk of abnormalities of glucose control. Method: Sixteen babies were studied from within 24 hours of delivery and for up to seven days. Results: The subcutaneous glucose sensors were well tolerated and readings were comparable to those on near patient whole blood monitoring devices. Conclusion: Continuous glucose monitoring is practical in neonates, giving detailed information about glucose control.

1 April 2021 in The Lancet Child & Adolescent Health
Verified
Journal Article
Open access
KBKathryn Beardsall
Kathryn Beardsall
LTLynn Thomson
Lynn Thomson
CGCatherine Guy
Catherine Guy
IIIsabel Iglesias-Platas
Isabel Iglesias-Platas
MWMirjam M van Weissenbruch
Mirjam M van Weissenbruch
ALAnnemieke de Lange
Annemieke de Lange
Hyperglycaemia and hypoglycaemia are common in preterm infants and have been associated with increased risk of mortality and morbidity. Interventions to reduce risk associated with these exposures are particularly challenging due to the infrequent measurement of blood glucose concentrations, with the potential of causing more harm instead of improving outcomes for these infants. Continuous glucose monitoring (CGM) is widely used in adults and children with diabetes to improve glucose control, but has not been approved for use in neonates. The REACT trial aimed to evaluate the efficacy and safety of CGM in preterm infants requiring intensive care. This international, open-label, randomised controlled trial was done in 13 neonatal intensive care units in the UK, Spain, and the Netherlands. Infants were included if they were within 24 h of birth, had a birthweight of 1200 g or less, had a gestational age up to 33 weeks plus 6 days, and had parental written informed consent. Infants were randomly assigned (1:1) to real-time CGM or standard care (with masked CGM for comparison) using a central web randomisation system, stratified by recruiting centre and gestational age (<26 or ≥26 weeks). The primary efficacy outcome was the proportion of time sensor glucose concentration was 2·6-10 mmol/L for the first week of life. Safety outcomes related to hypoglycaemia (glucose concentrations <2·6 mmol/L) in the first 7 days of life. All outcomes were assessed on the basis of intention to treat in the full analysis set with available data. The study is registered with the International Standard Randomised Control Trials Registry, ISRCTN12793535. Between July 4, 2016, and Jan 27, 2019, 182 infants were enrolled, 180 of whom were randomly assigned (85 to real-time CGM, 95 to standard care). 70 infants in the real-time CGM intervention group and 85 in the standard care group had CGM data and were included in the primary analysis. Compared with infants in the standard care group, infants managed using CGM had more time in the 2·6-10 mmol/L glucose concentration target range (mean proportion of time 84% [SD 22] vs 94% [11]; adjusted mean difference 8·9% [95% CI 3·4-14·4]), equivalent to 13 h (95% CI 5-21). More infants in the standard care group were exposed to at least one episode of sensor glucose concentration of less than 2·6 mmol/L for more than 1 h than those in the intervention group (13 [15%] of 85 vs four [6%] of 70). There were no serious adverse events related to the use of the device or episodes of infection. Real-time CGM can reduce exposure to prolonged or severe hyperglycaemia and hypoglycaemia. Further studies using CGM are required to determine optimal glucose targets, strategies to obtain them, and the potential effect on long-term health outcomes. National Institute for Health Research Efficacy and Mechanisms Evaluation Programme.

12 July 2012 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Closed access
PDF file
KBKathryn Beardsall
Kathryn Beardsall
SVS Vanhaesebrouck
S Vanhaesebrouck
AOA L Ogilvy-Stuart
A L Ogilvy-Stuart
CVC Vanhole
C Vanhole
MVM Vanweissenbruch
M Vanweissenbruch
DDDavid Dunger
David Dunger
Objective Recent studies have highlighted the need for improved methods of monitoring glucose control in intensive care to reduce hyperglycaemia, without increasing the risk of hypoglycaemia. Continuous glucose monitoring is increasingly used in children with diabetes, but there are little data regarding its use in the preterm infant, particularly at extremes of glucose levels and over prolonged periods. This study aimed to assess the accuracy of the continuous glucose monitoring sensor (CGMS) across the glucose profile, and to determine whether there was any deterioration over a 7 day period. Design Prospectively collected CGMS data from the NIRTURE Trial was compared with the data obtained simultaneously using point of care glucose monitors. Setting An international multicentre randomised controlled trial. Patients One hundred and eighty-eight very low birth weight control infants. Outcome measures Optimal accuracy, performance goals (American Diabetes Association consensus), Bland Altman, Error Grid analyses and accuracy. Results The mean (SD) duration of CGMS recordings was 156.18 (29) h (6.5 days), with a total of 5207 paired glucose levels. CGMS data correlated well with point of care devices (r=0.94), with minimal bias. It met the Clarke Error Grid and Consensus Grid criteria for clinical significance. Accuracy of single readings to detect set thresholds of hypoglycaemia, or hyperglycaemia was poor. There was no deterioration over time from insertion. Conclusions CGMS can provide information on trends in glucose control, and guidance on the need for blood glucose assessment. This highlights the potential use of CGMS in optimising glucose control in preterm infants.

21 July 2021 in Frontiers in Pediatrics
Verified
Journal Article
Open access
KBKathryn Beardsall
Kathryn Beardsall
Hyperglycemia is common in newborns requiring intensive care, particularly in preterm infants, in sepsis and following perinatal hypoxia. The clinical significance, and optimal intervention strategy varies with context, but hyperglycaemia is associated with increased mortality and morbidity. The limited evidence for optimal clinical targets mean controversy remains regarding thresholds for intervention, and management strategies. The first consideration in the management of hyperglycaemia must be to ascertain potentially treatable causes. Calculation of the glucose infusion rate (GIR) to insure this is not excessive, is critical but the use of insulin is often helpful in the extremely preterm infant, but is associated with an increased risk of hypoglycaemia. The use of continuous glucose monitoring (CGM) has recently been demonstrated to be helpful in targeting glucose control, and reducing the risk from hypoglycaemia in the preterm infant. Its use in other at risk infants remains to be explored, and further studies are needed to provide a better understanding of the optimal glucose targets for different clinical conditions. In the future the combination of CGM and advances in computer algorithms, to provide intelligent closed loop systems, could allow a safer and more personalized approached to management.