Zhi Cheng

Prof. Zhi Cheng

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2024 in International Journal of Impact Engineering
Verified
Journal Article
Closed access
YHYu-Jie Huang
Yu-Jie Huang
LHLu Hai
Lu Hai
QLQing-Hua Li
Qing-Hua Li
HZHui Zhang
Hui Zhang
ZCZhi Cheng
Zhi Cheng
SXShi-Lang Xu
Shi-Lang Xu

1 January 2018 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
ZCZhi Cheng
Zhi Cheng
ZCZhijun Cheng
Zhijun Cheng
HHHua Hou
Hua Hou
THTao Han
Tao Han
LLLan Liu
Lan Liu
Circulating fluidized bed combustion (CFBC) desulfurization slag is a waste residue discharged from coal power plants. In this article, expansion characteristics and compressive strength of mortars containing CFBC desulfurization slag were evaluated, subjected to mechanical grinding time, the amount of additive, and chemical activation. Correlations between the linear expansion rate and compressive strength were investigated. The hydration products of cement‐slag cementitious system were analyzed by X‐ray diffraction (XRD) and scanning electron microscopy (SEM). The results show that mechanical grinding can increase both the expansion and compressive strength of mortars containing CFBC desulfurization slag, and the compressive strength and linear expansion can develop in coordination. While increasing the amount of the fine desulfurization slag, the linear expansion rate increases, and the compressive strength reaches to the maximum when the amount is 30%. Moderate sodium sulfate as an activator can both promote the compressive strength and increase the expansion of mortars.

20 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
LLLan Liu
Lan Liu
LHLei He
Lei He
ZCZhi Cheng
Zhi Cheng
XWXiaoyi Wang
Xiaoyi Wang
ZMZhe Ma
Zhe Ma
XCXinrong Cheng
Xinrong Cheng
The interface bonding behavior between the steel tube and the concrete of concrete-filled steel tube (CFST) blended with circulating fluidized bed bottom ash (CFB-BA) was investigated in this study. A total of 8 groups of CFSTs stub columns were prepared with different dosage of CFB-BA, water-binder ratio (W/B), and interface bonding length. A series of push-out tests were carried out to acquire the data representing the interface bonding behavior. The results show that the dosage of CFB-BA has a direct effect on interface bonding behavior of CFST. CFB-BA can improve the interface bonding behavior of CFST. The highest ultimate bonding load and strength are achieved when the dosage of CFB-BA is 30%. When the dosage of CFB-BA increases to 50%, its interface bonding behavior decreases, but is still better than that of CFST without CFB-BA. W/B has a negative correlation with the interface bonding behavior of CFST. While the W/B increases, the interface bonding load and strength of CFST decreases. The increase of the interface bonding length can improve the interface bonding load, but cannot improve the interface bonding strength.

1 November 2019 in Journal of Materials in Civil Engineering
Verified
Journal Article
Closed access
ZCZhi Cheng
Zhi Cheng
XPXiaobo Pei
Xiaobo Pei
HHHua Hou
Hua Hou
THTao Han
Tao Han
LLLan Liu
Lan Liu
YHYunshan Han
Yunshan Han
This work provides a systematic analysis of the expansive and load-deformation behaviors in circular steel tube stub columns (CSTCs) of self-compacting concrete (SCC) blended with ground circulating fluidized bed (CFB) bottom ashes (BAs). A series of SCCs with different expansive properties was fabricated by adding CFB-BAs. As the dosage of CFB-BAs increased, the time-dependent circumferential and axial strains increased. The expansive and load-deformation behaviors of cured SCCs filling the CSTCs were evaluated. Time-dependent expansive strain (TDES) measurements revealed that the expansive behavior in both the circumferential and axial directions had the same variation trend. The circumferential TDES values were much larger than the axial values. The axial load-displacement relations indicated that the specimen with 30% CFB-BAs had a 34% higher ultimate load, and it had a 54% higher ultimate load when 1.5% sodium sulfate was added to the specimen. The prestress had a significant impact on the ultimate capacity of concrete-filled steel tubes (CFTs). However, the ultimate capacity still was determined by the compressive strength of the core concrete, and it was not directly proportional to the initial prestress. The specimen with a 4-mm wall thickness and 30% CFB-BAs gained the most ultimate stress, indicating that the wall thicknesses of steel tubes had a distinct influence on the load-deformation behavior.

1 January 2020 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
ZCZhi Cheng
Zhi Cheng
LHLei He
Lei He
LLLan Liu
Lan Liu
ZCZhijun Cheng
Zhijun Cheng
XPXiaobo Pei
Xiaobo Pei
ZMZhe Ma
Zhe Ma
This study investigates the mechanical properties and durability of three families of high‐performance concrete (HPC), in which the first was blended with fly ash, the second with circulating fluidized bed combustion (CFBC) ash, and the third with CFBC slag. In addition to each of the three mineral additives, silica fume and a superplasticizer were also incorporated into the HPC. Hence, three families of HPC, containing 10%, 20%, and 30% mineral admixtures and 9% silica fume of the binder mass, respectively, were produced. The microstructure and hydration products of the HPC families were examined by scanning electron microscopy (SEM) and X‐ray diffraction (XRD) to explore the influence of fly ash, CFBC ash, and CFBC slag on the compressive strength and frost resistance of HPC. The experimental results show that the compressive strength of HPC could reach 60 MPa at 28 d age. When the fly ash content was 30%, the compressive strength of HPC was 70.2 MPa at 28 d age; after the freeze‐thaw cycle, the mass loss and strength loss of HPC were 0.63% and 8.9%, respectively. When the CFBC ash content was 20%, the compressive strength of HPC was 75 MPa at 28 d age. After the freeze‐thaw cycle, the mass loss and strength loss of HPC were 0.17% and 0.81%, respectively.

30 September 2022 in Silicon
Verified
Journal Article
Closed access
PDF file
ZCZhi Cheng
Zhi Cheng
XCXinrong Cheng
Xinrong Cheng
ZCZhijun Cheng
Zhijun Cheng
CSChongxian Suo
Chongxian Suo
HZHongping Zhang
Hongping Zhang
YLYuhao Liu
Yuhao Liu