Daniel Kotrych

Dr. Daniel Kotrych


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2016 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
PDF file
MBMichaël P. A. Bus
Michaël P. A. Bus
ASAndrzej Szafranski
Andrzej Szafranski
SSSimen Sellevold
Simen Sellevold
TGTomasz Goryn
Tomasz Goryn
PJPaul C. Jutte
Paul C. Jutte
SDSander P.D. Dijkstra
Sander P.D. Dijkstra
Background Reconstruction of periacetabular defects after pelvic tumor resection ranks among the most challenging procedures in orthopaedic oncology, and reconstructive techniques are generally associated with dissatisfying mechanical and nonmechanical complication rates. In an attempt to reduce the risk of dislocation, aseptic loosening, and infection, we introduced the LUMiC® prosthesis (implantcast, Buxtehude, Germany) in 2008. The LUMiC® prosthesis is a modular device, built of a separate stem (hydroxyapatite-coated uncemented or cemented) and acetabular cup. The stem and cup are available in different sizes (the latter of which is also available with silver coating for infection prevention) and are equipped with sawteeth at the junction to allow for rotational adjustment of cup position after implantation of the stem. Whether this implant indeed is durable at short-term followup has not been evaluated. Questions/purposes (1) What proportion of patients experience mechanical complications and what are the associated risk factors of periacetabular reconstruction with the LUMiC® after pelvic tumor resection? (2) What proportion of patients experience nonmechanical complications and what are the associated risk factors of periacetabular reconstruction with the LUMiC® after pelvic tumor resection? (3) What is the cumulative incidence of implant failure at 2 and 5 years and what are the mechanisms of reconstruction failure? (4) What is the functional outcome as assessed by Musculoskeletal Tumor Society (MSTS) score at final followup? Methods We performed a retrospective chart review of every patient in whom a LUMiC® prosthesis was used to reconstruct a periacetabular defect after internal hemipelvectomy for a pelvic tumor from July 2008 to June 2014 in eight centers of orthopaedic oncology with a minimum followup of 24 months. Forty-seven patients (26 men [55%]) with a mean age of 50 years (range, 12–78 years) were included. At review, 32 patients (68%) were alive. The reverse Kaplan-Meier method was used to calculate median followup, which was equal to 3.9 years (95% confidence interval [CI], 3.4–4.3). During the period under study, our general indications for using this implant were reconstruction of periacetabular defects after pelvic tumor resections in which the medial ilium adjacent to the sacroiliac joint was preserved; alternative treatments included hip transposition and saddle or custom-made prostheses in some of the contributing centers; these were generally used when the medial ilium was involved in the tumorous process or if the LUMiC® was not yet available in the specific country at that time. Conventional chondrosarcoma was the predominant diagnosis (n = 22 [47%]); five patients (11%) had osseous metastases of a distant carcinoma and three (6%) had multiple myeloma. Uncemented fixation (n = 43 [91%]) was preferred. Dual-mobility cups (n = 24 [51%]) were mainly used in case of a higher presumed risk of dislocation in the early period of our study; later, dual-mobility cups became the standard for the majority of the reconstructions. Silver-coated acetabular cups were used in 29 reconstructions (62%); because only the largest cup size was available with silver coating, its use depended on the cup size that was chosen. We used a competing risk model to estimate the cumulative incidence of implant failure. Results Six patients (13%) had a single dislocation; four (9%) had recurrent dislocations. The risk of dislocation was lower in reconstructions with a dual-mobility cup (one of 24 [4%]) than in those without (nine of 23 [39%]) (hazard ratio, 0.11; 95% CI, 0.01–0.89; p = 0.038). Three patients (6%; one with a preceding structural allograft reconstruction, one with poor initial fixation as a result of an intraoperative fracture, and one with a cemented stem) had loosening and underwent revision. Infections occurred in 13 reconstructions (28%). Median duration of surgery was 6.5 hours (range, 4.0–13.6 hours) for patients with an infection and 5.3 hours (range, 2.8–9.9 hours) for those without (p = 0.060); blood loss was 2.3 L (range, 0.8–8.2 L) for patients with an infection and 1.5 L (range, 0.4–3.8 L) for those without (p = 0.039). The cumulative incidences of implant failure at 2 and 5 years were 2.1% (95% CI, 0–6.3) and 17.3% (95% CI, 0.7–33.9) for mechanical reasons and 6.4% (95% CI, 0–13.4) and 9.2% (95% CI, 0.5–17.9) for infection, respectively. Reasons for reconstruction failure were instability (n = 1 [2%]), loosening (n = 3 [6%]), and infection (n = 4 [9%]). Mean MSTS functional outcome score at followup was 70% (range, 33%–93%). Conclusions At short-term followup, the LUMiC® prosthesis demonstrated a low frequency of mechanical complications and failure when used to reconstruct the acetabulum in patients who underwent major pelvic tumor resections, and we believe this is a useful reconstruction for periacetabular resections for tumor or failed prior reconstructions. Still, infection and dislocation are relatively common after these complex reconstructions. Dual-mobility articulation in our experience is associated with a lower risk of dislocation. Future, larger studies will need to further control for factors such as dual-mobility articulation and silver coating. We will continue to follow our patients over the longer term to ascertain the role of this implant in this setting. Level of Evidence Level IV, therapeutic study.

16 April 2019 in BioMed Research International
Verified
Journal Article
Open access
PDF file
Paweł ŁęgoszPaweł Łęgosz
Paweł Łęgosz
MOMaciej Otworowski
Maciej Otworowski
ASAleksandra Sibilska
Aleksandra Sibilska
KSKrzysztof Kazimierz Starszak
Krzysztof Kazimierz Starszak
DKDaniel Kotrych
Daniel Kotrych
MSMarek Synder
Marek Synder
Background. This review is intended to summarize the risk factors, classification, diagnosis, and treatment of heterotopic ossification (HO) of previously published studies. Results. Heterotopic ossification is a common complication of total hip arthroplasty. Its prevalence is not the same in all of the patient groups. Frequency of HO varies from 15 to 90%. Hip ankylosis, male gender, and previous history of HO are said to be risk factors with a significant level. Diagnosis is based on a single AP radiograph: the Brooker classification that divides HO into four grades is the most commonly used. The confirmation test that can be used is a bone scan. A great amount of bone metabolic turnover markers have been tested, but none of them seems to be relevant in case of prevention or diagnosis of HO. The most effective prophylactic treatment is radiotherapy or administration of nonsteroidal anti-inflammatory drugs. Over the years a lot of different RT protocols have been tested. Nowadays the most often used regimen is 7 Gy given postoperatively in a single dose. The most commonly prescribed drug in prophylaxis of HO is indomethacin. Also, the efficacy of ibuprofen and diclofenac was proven. Recently researchers focused on selective COX-2 inhibitors. They appear to be as effective as nonselective NSAIDs having less side effects. The one and only treatment of HO is a revision arthroplasty.

13 March 2020 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
Andrea AngeliniAndrea Angelini
Andrea Angelini
DKDaniel Kotrych
Daniel Kotrych
GTGiulia Trovarelli
Giulia Trovarelli
ASAndrzej Szafrański
Andrzej Szafrański
ABAndrzej Jan Bohatyrewicz
Andrzej Jan Bohatyrewicz
Pietro RuggieriPietro Ruggieri
Pietro Ruggieri

1 March 2010 in European Journal of Obstetrics & Gynecology and Reproductive Biology
Verified
Journal Article
Closed access
BCBogusław Czerny
Bogusław Czerny
AKAdam Kamiński
Adam Kamiński
MKMateusz Kurzawski
Mateusz Kurzawski
DKDaniel Kotrych
Daniel Kotrych
KSKrzysztof Safranow
Krzysztof Safranow
APAndrzej Pawlik
Andrzej Pawlik

11 May 2016 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
APAndrzej Pawlik
Andrzej Pawlik
DKDaniel Kotrych
Daniel Kotrych
DMDamian Malinowski
Damian Malinowski
VDVioletta Dziedziejko
Violetta Dziedziejko
MCMichał Czerewaty
Michał Czerewaty
KSKrzysztof Safranow
Krzysztof Safranow
Interleukin-17 plays important role in the pathogenesis of rheumatoid arthritis (RA). The aim of this study was to examine the associations between polymorphisms in the IL17A and IL17F genes and RA. We examined 422 RA patients and 337 subjects as a control group. Single nucleotide polymorphism (SNP) in the IL17A (rs2275913) and IL17F (rs763780, rs11465553, rs2397084) genes were genotyped using TaqMan genotyping assays from Life Technologies Genomic. There were no significant differences in distribution of IL17A and IL17F genotypes and alleles between RA patients and control group. There were no significant associations between IL17A and IL17F genotypes and age of disease diagnosis rheumatoid factor, erosive disease as well as extra-articular manifestations. The results of this study suggest, that IL17A and IL17F gene polymorphism are not the important factors associated with susceptibility and some clinical parameters of RA in a Polish population.

1 May 2023 in EFORT Open Reviews
Verified
Journal Article
Open access
PDF file
DKDaniel Kotrych
Daniel Kotrych
Andrea AngeliniAndrea Angelini
Andrea Angelini
ABAndrzej Bohatyrewicz
Andrzej Bohatyrewicz
Pietro RuggieriPietro Ruggieri
Pietro Ruggieri
Satisfactory results in terms of functional and oncological outcomes can be obtained in sacral and pelvic malignant bone tumors. Preoperative planning, adequate imaging, and a multidisciplinary approach are needed. 3D-printed prostheses have to fulfill several requirements: (i) mechanical stability, (ii) biocompatibility, (iii) implantability, and (iv) diagnostic compatibility. In this review, we highlight current standards in the use of 3D-printed technology for sacropelvic reconstruction.