This paper presents the experimental and theoretical results of small and medium-scale concrete-filled fiber-reinforced polymer (FRP) tube (CFFT) columns. A total of 23 CFFT specimens were tested under axial compression load. Five different types of new FRP tubes were used as stay-in-place formwork for the columns. The effects of the following parameters were examined: the FRP-confinement ratio, the unconfined concrete compressive strength, the presence of longitudinal steel reinforcement, and the height-to-diameter ratio. Comparisons between the experimental test results and the theoretical prediction values by the three North American codes and design guidelines (ACI 440.2R-08, CSA-S6-06, and CSA-S806-02) are performed in terms of confined concrete strength and ultimate load carrying capacity. The results of this investigation indicate that the design equations of the ACI 440.2R-08, CAN/CSA-S6-06, and CAN/CSA-S806-02 overestimate the factored axial load capacity of the short CFFT columns as compared to ...
1 April 2017 in Journal of Composites for Construction
North America’s current design codes and guidelines allow the use of fiber–reinforced polymer (FRP) bars as the primary reinforcement in concrete structures and provide design recommendations for using these bars. Because of a lack of experimental data, however, FRP bars have not been recommended for resisting compression stresses as longitudinal reinforcement in columns or compression reinforcement in flexural elements. This paper presents test results of an experimental program to investigate the structural performance of 10 full-scale circular concrete columns reinforced with carbon fiber–reinforced polymer (CFRP) bars and spirals subjected to combined axial compression loads and bending moments. The test variables include different eccentricity-to-diameter ratios and two types of reinforcement (CFRP and steel). The test results show that the CFRP- and steel-reinforced concrete columns behaved similarly up to their peak loads. The failure of the test specimens under different levels of eccentri...
1 April 2017 in Journal of Composites for Construction
Integrating fiber-reinforced polymer (FRP) reinforcement into high-strength concrete (HSC) would effectively contribute to enhancing the stiffness of cracked concrete sections when the FRP bars are undergoing high strain and stress levels. Nonetheless, neither the concentric nor the eccentric behavior of HSC columns reinforced with FRP reinforcement has yet been investigated. This paper presents the results of an experimental investigation on the concentric and eccentric behavior of full-scale circular HSC columns reinforced with glass FRP (GFRP) bars and spirals. A total of 10 columns were tested under monotonic loading with different eccentricities. The test variables were the eccentricity-to-diameter ratio and the longitudinal-reinforcement ratio. Compression failure in the concrete controlled the ultimate capacity of specimens tested under small eccentric loading. A flexural-tension failure initiated in specimens tested under high eccentric loading, however, resulted from excessive axial and l...