This paper presents the experimental and theoretical results of small and medium-scale concrete-filled fiber-reinforced polymer (FRP) tube (CFFT) columns. A total of 23 CFFT specimens were tested under axial compression load. Five different types of new FRP tubes were used as stay-in-place formwork for the columns. The effects of the following parameters were examined: the FRP-confinement ratio, the unconfined concrete compressive strength, the presence of longitudinal steel reinforcement, and the height-to-diameter ratio. Comparisons between the experimental test results and the theoretical prediction values by the three North American codes and design guidelines (ACI 440.2R-08, CSA-S6-06, and CSA-S806-02) are performed in terms of confined concrete strength and ultimate load carrying capacity. The results of this investigation indicate that the design equations of the ACI 440.2R-08, CAN/CSA-S6-06, and CAN/CSA-S806-02 overestimate the factored axial load capacity of the short CFFT columns as compared to ...
1 October 2005 in Journal of Composites for Construction
Fiber reinforced polymers (FRPs) have a thermal expansion in the transverse direction much higher than in the longitudinal direction and also higher than the thermal expansion of hardened concrete. The difference between the transverse coefficient of thermal expansion of FRP bars and concrete may cause splitting cracks within the concrete under temperature increase and, ultimately, failure of the concrete cover if the confining action of concrete is insufficient. This paper presents the results of an experimental investigation to analyze the effect of the ratio of concrete cover thickness to FRP bar diameter (c∕ db ) on the strain distributions in concrete and FRP bars, using concrete cylindrical specimens reinforced with a glass FRP bar and subjected to thermal loading from −30 to +80°C . The experimental results show that the transverse coefficient of thermal expansion of the glass FRP bars tested in this study is found to be equal to 33 (× 10−6 mm∕mm∕°C) , on average and the ratio between the transvers...
The large temperature variation has a harmful effect on concrete structures reinforced with fiber reinforced polymer (FRP) bars. This is due to the significant difference between transverse coefficient of thermal expansion of these bars and that of the hardened concrete. This difference generates a radial pressure at the FRP bar/concrete interface, and may cause splitting cracks within concrete. This paper presents results of an experimental and analytical study carried out on FRP-reinforced concrete slabs subjected, simultaneously, to thermal and mechanical loads. The analytical model based on the theory of linear elasticity consists to evaluate combined effects of thermal and mechanical loads on the transverse expansion of FRP bars. Parameters studied in this investigation are the concrete cover thickness, FRP bar diameter, and the temperature variation. The thermal cycles were varied from −30 to +60 °C. Comparisons between analytical and experimental results show that transverse strains predicted from the proposed model are in good correlation with experimental results.
This paper aims at investigating the general axial behavior of long circular concrete-filled, fiber-reinforced polymer (FRP) tube (CFFT) columns internally reinforced with different longitudinal rebars. A total of seven CFFT and three reinforced concrete (RC) columns served as control specimens for comparisons and were constructed and tested under cyclic axial loading until failure. The test parameters were: (1) internal reinforcement type (steel, glass fiber-reinforced polymer (GFRP) or carbon fiber-reinforced polymer (CFRP)) and amount; (2) GFRP tube thicknesses; and (3) nature of loading. All columns had 1900-mm in height and 213-mm in diameter. Examination of the test results has led to a number of significant conclusions in regards to the trend and ultimate condition of the axial stress-strain behavior, mode of failure of tested CFFT columns, and plastic strains. As expected, an increase in the FRP tube thickness (or stiffness) resulted in an increase in the strength and strain enhancement ratios. The validity of the available design provisions for predicting the ultimate load-carrying capacity of tested columns is also highlighted.
10 April 2024 in Construction and Building Materials